Empire Comfort Systems DV33IN33L, DV25IN33L, DV35IN33L Blower Accessory Information

Page 16

BLOWER ACCESSORY INFORMATION

The appliance, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.

U.S. Installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70.

Should this blower require servicing, the power supply must be disconnected. For rewiring of any replacement components, re- fer to Figures 16 and 17 and the parts list on page 25.

BLOWER ACCESSORY

Operation

The fireplace insert is equipped with a factory installed blower accessory that includes a fan control switch, plus a rheostat (speed control).

The speed control knob is located behind the lower louver at the right side of the insert.

From a cold start, the temperature activated fan control switch will normally take 5-10 minutes to heat up and energize the blower.

Once the blower is energized, adjust the blower speed control as desired, then replace the lower louver.

When the insert is shut off, it may take 30-40 minutes for the heated unit to dissipate (cool down) enough for the blower to shut off automatically. Note: The blower shut off times will vary on blower speed and BTU input level setting control by adjustment of the HI/LO knob located on the gas valve.

Blower removal instructions

Servicing or removal of the blower system must be performed by a qualified service person.

If the blower assembly (Item 45, page 24) must be replaced, the following steps are recommended for removal:

1.Turn off gas and disconnect the electrical supply.

2.Remove the glass door assembly.

3.Remove the log set.

4.Remove the front surround panel assembly by lifting upward and outward to detach.

5.Remove the 5/16” x 2-1/2” center bolt that retains the Vent Slide plate assembly.

6.Remove the insert from the fireplace cavity by pulling forward on the insert, and at the same time, sliding the vent plate rearward until disengaged.

7.As the insert is moved outward, the gas line may need to be disconnected at the insert shut off valve. If so, make sure the main gas line is shut off that supplies gas to the insert.

8.Once the insert is pulled out, the blower assembly can be removed by locating the (6) screws on the lower back of the insert that retains the blower base plate.

9.When the screws are removed, gently pull the blower assembly outward.

10.Disconnect the two ¼” wire terminals from the motor.

11.Remove the (4) screws that retain the blower assembly to the base plate, and set blower aside.

12.Install the replacement blower, and re-install the insert by reversing above steps.

Figure 16

Figure 17

Page 16

23015-3-0707

Image 16
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP GAS LP-GAS Warning OdorIntroduction Specifications Fireplace Insert Dimensions DV Fireplace Insert DimensionsMantle and Trim Clearances Combustible MaterialGAS Supply Installing the Main Gas CockChecking Manifold Pressures Venting and Installation Installing the Vent SystemVent System Approvals Rectangular Termination CAP DVVK3FV KIT General Maintenance Vertical TerminationDetermining Minimum Vent Height Above the Roof Vertical Through the Roof ApplicationsAlternate ON/OFF Switch Installation Wiring the FireplaceSurround Panel Installation Blower Accessory Information Blower AccessoryLOG Placement Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureFor Your Safety Read Before Lighting Standing Pilot Lighting InstructionsStanding Pilot Wiring Standing Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass soots, and/or soot deposits collected on logsInsert Maintenance and Service Important Turn OFF the GAS Before Servicing Your ApplianceDecorative Accessories Insert Parts View Insert Parts List DV25IN33LN,P DV33IN33LN,P DV35IN33LN,PHOW to Order Repair Parts Service NotesService Notes