SPECIFICATIONS

DV25IN33L MODELS

LP

Nat

Input Btu/hr Maximum

25,000

25,000

Btu/hr Minimum

17,000

17,000

KWH (Maximum)

7.30

7.30

(Minimum)

5.00

5.00

Orifice

#53 (0.0596)

#42 (0.0935)

Air Shutter Opening

Full Open

1/8”

DV33IN33L MODELS

LP

Nat

Input Btu/hr Maximum

33,000

33,000

Btu/hr Minimum

25,000

25,000

KWH (Maximum)

9.57

9.57

(Minimum)

7.30

6.67

Orifice

#51 (0.067)

#34 (0.111)

Air Shutter Opening

Full Open

3/16”

DV35IN33L MODELS

LP

Nat

Input Btu/hr Maximum

35,000

35,000

Minimum

27,000

25,000

KWH (Maximum)

10.15

10.15

(Minimum)

7.83

7.30

Orifice

#50 (0.070)

#33 (0.113)

Air Shutter Opening

Full Open

3/16”

Remote Control

Description

Accessories

 

FRBC

Millivolt Battery Remote ON/OFF

FRBTC

Millivolt Battery Remote T-Stat

TMV

Millivolt WIRELESS Wall Thermostat

TRW

Millivolt Reed Switch Wall Thermostat

Surround Kits

Description

 

Contemporary

S256BL

6” Wide, black for use on DV25IN models

S336BL

6” Wide, black for use on DV33IN models

S356BL

6” Wide, black for use on DV35IN models

 

Traditional Cast Iron

SC256BL

6” Wide, black for use on DV25IN models

SC336BL

6” Wide, black for use on DV33IN models

SC356BL

6” Wide, black for use on DV35IN models

Venting Kits

Description

Contents

DVKI

Vertical Vent Kit - 17 1/2’

One piece of 35’ FlexVent (split for 17 1/2’ vent run), Round Cap, Flashing,

 

 

connectors, and clamps.

 

 

Recommended when installing to an existing round fireplace chimney pipe.

DVVK3FV

Vertical Vent Kit - 25’

Two pieces of 25’ FlexVent, Rectangle Cap, Flashing, connectors, and clamps

 

 

Recommended when installing to a square or rectangular clay flue.

DVK35

Vent Extension Kit

35’ flex vent extension section with 2 connectors and 4 clamps

Note: When installing vent caps, special locally made flashings may be required to properly seal the vent system to the existing chimney termination.

Page 6

23015-3-0707

Image 6
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP GAS LP-GAS Warning OdorIntroduction Specifications Fireplace Insert Dimensions DV Fireplace Insert DimensionsMantle and Trim Clearances Combustible MaterialInstalling the Main Gas Cock GAS SupplyChecking Manifold Pressures Venting and Installation Installing the Vent SystemVent System Approvals Rectangular Termination CAP DVVK3FV KIT Determining Minimum Vent Height Above the Roof General MaintenanceVertical Termination Vertical Through the Roof ApplicationsAlternate ON/OFF Switch Installation Wiring the FireplaceSurround Panel Installation Blower Accessory Information Blower AccessoryLOG Placement Initial Lighting Operating InstructionsMillivolt System Pilot Flame FigureFor Your Safety Read Before Lighting Standing Pilot Lighting InstructionsStanding Pilot Wiring Pilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass soots, and/or soot deposits collected on logsInsert Maintenance and Service Important Turn OFF the GAS Before Servicing Your ApplianceDecorative Accessories Insert Parts View Insert Parts List DV25IN33LN,P DV33IN33LN,P DV35IN33LN,PHOW to Order Repair Parts Service NotesService Notes