FIREPLACE INSERT DIMENSIONS
When planning a fireplace insert installation, it’s necessary to determine:
•The vent system configuration to be used.
•Gas supply piping.
•
•
•
Whether optional accessories - devices such as a wall switch or remote control - are desired.
Electrical supply requirements for blower.
Proper opening size of fireplace required for installation of the fireplace insert.
DV FIREPLACE INSERT DIMENSIONS
MODEL | A | B | C | D | E | F | G | H | I | J | K | L | M | N |
DV25IN | 19 3/8” | 28 | 14 1/2” | 11 1/8” | 25 1/4” | 12 3/4” | 17” | 18 5/16” | 27” | 6 3/4” | 9” | 20” | 25 3/8” | 40” |
DV33IN | 22 3/8” | 31 | 16 | 14 1/8” | 28 1/4” | 14 1/4” | 18 3/4” | 21 5/16” | 30” | 8 1/4” | 10 1/2” | 21 1/2” | 28 3/8” | 43” |
DV35IN | 24 3/8” | 34 | 16 | 16 1/8” | 31 1/4” | 14 1/4” | 21 3/4” | 23 5/16” | 33” | 8 1/4” | 10 1/2” | 23” | 30 3/8” | 46” |
Figure 1
Fireplace Opening Dimensional Information/Sizing
MINIMUM FIREPLACE OPENING DIMENSIONS
MODEL | HEIGHT | FRONT WIDTH | DEPTH | REAR WIDTH |
NO. | A* | B | C | D |
|
|
|
|
|
DV25IN | 18 3/8” | 27 1/2” | 12 3/4” | 17 1/4” |
DV33IN | 21 3/8” | 30 1/2” | 14 1/4” | 19” |
DV35IN | 23 3/8” | 33 1/2” | 14 1/4” | 22” |
*Note: If the fireplace lintel is wider than 8” (203mm), the height of the fireplace opening must be increased a few inches to allow for a gradual offset in the exhaust and/or intake vent pipes.
D
C
A
B
Figure 2
Page 7 |