Empire Comfort Systems BF-10-2 Main Burner Flame Characteristics, Air Shutter Adjustment Figure

Page 11

MAIN BURNER FLAME CHARACTERISTICS

Piezo Pilot Ignitor Instructions

Depressing the ignitor button completely causes a spark to occur at the pilot.

To light the pilot, it is important that the electrode be 1/8" (3mm) from the pilot. The spark must occur at the point the pilot flame hits the thermocouple.

On a new installation with air in the gas line, it is suggested that a match be used. The match will light the pilot faster than the piezo under this condition.

There will be a short blue inner flame with a much larger, lighter blue, secondary flame. The burner flame may have a small yellow tip when hot. Dust in the combustion air will produce an orange or red flame. Do not mistake the orange or red flame for an improper yellow flame. Clean main burner by applying compressed air into ports and throat of main burner.

Figure 9

Attention: BF-10, Natural or Propane gas has a front and rear air shutter.

BF-20, Propane gas only has a front air shutter. BF-30, Propane gas only has a front air shutter.

Air Shutter Adjustment (Figure 10)

The air shutter on main burner is factory set at a 3/32" opening. If yellow flames occur on main burner loosen 1/4" screw on air shutter in order to increase air shutter opening. The slot on air shutter allows the air opening to be increased or decreased. Tighten 1/4" screw on air shutter after air shutter adjustment has been completed.

Figure 10

Cleaning Main Burner Orifice and Main Burner

1.Turn OFF gas supply to the heater.

2.Turn OFF electric supply to the heater if optional blower, SRB-18T or SRB-30T is installed in heater.

3.Remove lower louver from casing assembly (2 screws).

4.Remove reflector from casing assembly (2 screws).

5.Inspect interior of casing assembly for accumulation of dust, lint or spider webs. If necessary, clean interior of casing assembly with a vacuum cleaner or apply air pressure. Do not damage any components within casing assembly when you are cleaning.

6.Remove main burner orifice from orifice holder.

7.Apply air pressure through main burner orifice and orifice holder to remove dust, lint or spider webs.

8.Apply air pressure into main burner to remove dust, lint or spider webs.

9.As parts are being replaced in reverse order, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly.

16943-5-0806

Page 11

Image 11
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsUnusually Tight Construction Water Vapor a BY-PRODUCT of Unvented Room HeatersRecommended Gas Pipe Diameter GAS SupplyClearances Optional Floor Stand InstallationSRS-18* and SRS-30 Floor Stand Installation Installation on Rugs and TileBF-10 and BF-20 On Sheet Rock Wall Wall Mount InstallationLighting Instructions For Your Safety Read Before LightingPiezo Pilot Ignitor Instructions Main Burner Flame CharacteristicsAir Shutter Adjustment Figure Cleaning Main Burner Orifice and Main BurnerBF-10 Pilot Flame CharacteristicsThermostat Operation Oxygen Depletion Sensor Pilot FigureAppliance Maintenance Troubleshooting HOW to Order Repair Parts Parts ListParts View Installing Optional Blower SRB-18T or SRB-30T Optional Blower Installation InstructionsOptional Blower Installation Instructions Service Notes
Related manuals
Manual 20 pages 38.02 Kb