Empire Comfort Systems BF-10-2, BF-30-2, BF-20-2 installation instructions Troubleshooting

Page 14

TROUBLESHOOTING

SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS

1.Spark electrode does not produce spark.

a.Spark electrode broken - replace.

b.Ignitor wire may not be attached to spark electrode - attach.

c.Ignitor wire damaged - replace.

d.Piezo ignitor defective - replace.

2.Spark electrode produces spark but pilot does not light.

a.No gas to heater - turn on gas.

b.PILOT position not properly aligned - turn gas control knob to PILOT position and depress.

c.Pilot is blocked from spider web or dirt - clean pilot, see Figure 12, Page 12.

3.Pilot flame does not stay "ON" when control knob is released.

a.Control knob in PILOT position not completely depressed or held in long enough.

b.INTERLOCK latching device is operative - see "Lighting Instructions," Page 10, Step 9.

c.Thermocouple lead not tightened into gas control - tighten thermocouple lead.

d.Pilot flame not surrounding thermocouple - clean pilot, see Figure 12, Page 12.

e.Inlet gas pressure too low, contact gas supplier.

f.Thermocouple defective - replace pilot.

g.Gas control defective - replace.

4.Main burner does not ignite.

a.Main burner orifice is blocked - clean, see "Main Burner Flame Characteristics," Page 11.

b.Inlet gas pressure too low, contact gas supplier.

5.Heater keeps shutting "OFF" during normal operation.

a.Pilot is blocked - clean pilot, see Figure 12, Page 12.

b.Inlet gas pressure too low, contact gas supplier

Page 14

16943-5-0806

Image 14
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications IntroductionWater Vapor a BY-PRODUCT of Unvented Room Heaters Unusually Tight ConstructionGAS Supply Recommended Gas Pipe DiameterInstallation on Rugs and Tile Optional Floor Stand InstallationSRS-18* and SRS-30 Floor Stand Installation ClearancesWall Mount Installation BF-10 and BF-20 On Sheet Rock WallFor Your Safety Read Before Lighting Lighting InstructionsCleaning Main Burner Orifice and Main Burner Main Burner Flame CharacteristicsAir Shutter Adjustment Figure Piezo Pilot Ignitor InstructionsOxygen Depletion Sensor Pilot Figure Pilot Flame CharacteristicsThermostat Operation BF-10Appliance Maintenance Troubleshooting Parts List HOW to Order Repair PartsParts View Optional Blower Installation Instructions Installing Optional Blower SRB-18T or SRB-30TOptional Blower Installation Instructions Service Notes