INTRODUCTION
Instructions to Installer
1.Installer must leave instruction manual with owner after instal- lation.
2.Installer must have owner fill out and mail warranty card sup- plied with unvented room heater.
3.Installer should show owner how to start and operate unvented room heater.
Always consult your local Building Department regarding regu- lations, codes or ordinances which apply to the installation of an unvented room heater.
This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
General Information
This
Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company mak- ing the change.
WARNING: This appliance is equipped for (natural gas or propane) gas. Field conversion is not permitted.
Important
All correspondence should refer to complete Model Number, Serial Number and type of gas.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip- ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servic- ing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas- sachusetts.
Sellers of unvented propane or natural
In the State of Massachusetts, unvented propane and natural
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54.*
*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be reduced at the rate of 4 percent for each 1,000 (305m) feet above sea level. Contact the manufacturer or your gas company before changing spud/orifice size.
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the Btu output of the unit. Contact the gas company for the heat- ing value. Contact the manufacturer or your gas company before changing spud/orifice size.
SPECIFICATIONS
Specifications |
|
|
|
Model | |||
Input Btu/HR (KW/H)(LP) | 10,000 (2.9) | 20,000 (5.8) | 30,000 (8.8) |
Input Btu/HR (KW/H)(NAT) | 10,000 (2.9) | 18,000 (5.3) | 30,000 (8.8) |
Height | 22" (559mm) | 22" (559mm) | 22" (559mm) |
Width | 18" (457mm) | 18" (457mm) | 24 1/8" (536mm) |
Depth | 6 1/2" (165mm) | 6 1/2" (165mm) | 6 1/2" (165mm) |
Gas Inlet | 3/8" (10mm) | 3/8" (10mm) | 3/8" (10mm) |
Accessories |
|
|
|
Blower |
|
| |
Floor Stand |
The bedroom must be an unconfined space. ANSI Z223.1/NFPA 54 defines an unconfined space as "a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space."
Page 5 |