Make sure grille guard is in place before running heater. If screen or grille guard is removed for servicing it must be replaced prior to operating the heater.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

CLEANING ODS/PILOT AND BURNER

Use as vacuum cleaner, pressurized air or small soft bristled brush to clean.

CLEANING BURNER PILOT AIR HOLE INLET

We recommend that you clean the unit ever 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 psig.

This can be done by using a vacuum cleaner in the blow position, using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can you could damage the burner or pilot assem- bly. In addition, the directions that follow should also be followed.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner and pilot for dust and dirt.

3.Blow air through the port/slots and holes in the burner.

A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. To clean the pilot assembly find the small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Pilot Air Inlet Hole in figure 25). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

SPECIFICATIONS

 

 

MHVFB10LP

 

 

BTU (Available)

 

10,000

Type of Gas

LP-Gas Only

 

 

Ignition

Piezo

Pressure Regulator Setting

10 Inches of

 

 

Water

Inlet Gas Pressure (Maximum)

14 Inches of

 

 

Water

Inlet Gas Pressure (Minimum)

11 Inches of

 

 

Water

Burners / Orifice nozzles

1

 

 

Thermostatic Control

No

 

 

Clearances: inches (mm)

 

Top

36 (915)

 

 

Sides

6 (152)

 

 

Floor (min. to top of carpet)

2 (51)

 

 

Fabric / flammable objects

36 (915)

 

 

 

Figure 25

CLEANING HEATER CABINET

Air passageways

Use a vacuum cleaner or pressurized air to clean Exterior

11Installation instructions and Owner’s Manual

Image 11
Contents MR. Heater Propane/LP Gas PrecautionsCarbon Monoxide Poisoning Unpacking Safety DeviceLocal Codes Ignition SystemVentilation from Outdoors Ventilation AIRVentilation from Inside Building Fastening Heater to Wall Installation Check GAS TypeFor Permanent Installation Locating HeaterAttaching to Wall Stud Connecting to GAS Supply for Permanent Installation Installing Bottom Mounting ScrewsTest pressure in Excess of ½ psig 3.5kPa Pressure Testing Heater Gas ConnectionsLighting Instructions What to do if YOU Smell GASPilot Flame Pattern Cleaning and MaintenanceTo Turn OFF GAS to Appliance Inspecting BurnerCleaning Heater Cabinet SpecificationsCleaning ODS/PILOT and Burner Cleaning Burner Pilot AIR Hole InletObserved Symptom Possible Cause Remedy TroubleshootingObserved Symptom Possible Cause Remedy Troubleshooting CON’TParts List Description QTY Enerco GROUP, INC., 4560 W TH ST., CLEVELAND, Ohio Warranty Information

MHVFB10LP specifications

The Enerco MHVFB10LP is a high-performance propane infrared heater that has made its mark in the heating equipment industry, thanks to its innovative design and advanced technology. Built for both indoor and outdoor use, this versatile heater is particularly popular for its reliability and efficiency in providing warmth in various settings, including garages, workshops, and outdoor gatherings.

One of the standout features of the MHVFB10LP is its high-efficiency infrared heating capability. Unlike conventional heaters that rely on air convection, this unit delivers heat directly to objects and people in its vicinity. This direct heating method not only ensures faster warmth but also reduces energy waste, making it an economical choice for users. With a heating capacity of up to 10,000 BTUs, it can effectively warm spaces up to 250 square feet.

The Enerco MHVFB10LP is equipped with a state-of-the-art Piezo ignition system, which allows for easy and reliable start-up without the need for matches or lighters. Its adjustable heat settings provide flexibility, enabling users to customize their heating experience depending on the specific needs of the environment. Additionally, the heater features a durable construction made from high-quality materials, ensuring longevity and resilience in both indoor and outdoor conditions.

Safety is paramount in the design of the MHVFB10LP. The model includes an integrated safety shut-off system that activates in the event of a tip-over or if the flame goes out, providing peace of mind during use. The heater also features a sturdy base, ensuring stability and reducing the risk of accidental tipping.

Another notable characteristic of the Enerco MHVFB10LP is its compact and portable design. Weighing moderately and featuring a convenient handle, it allows users to easily move the heater wherever needed. This mobility makes it an ideal choice for construction sites, event setups, and home use.

In summary, the Enerco MHVFB10LP stands out for its efficient infrared heating technology, user-friendly features, safety components, and portability. Whether used for work or leisure, this heater is an excellent investment for anyone looking to enjoy warmth and comfort in any environment. With a combination of safety, efficiency, and versatility, the MHVFB10LP delivers exceptional performance that meets the heating needs of various users.