Enerco HS300ID, HS180ID manual Specifications, Appliance Description, Installation Instructions

Page 3

SPECIFICATIONS

MODEL #

180

300

Thermal power (BTU/hr)

181,000

289,000

Air Flow Rating (ft³/min)

1475

2650

Oil Consumption (gal/hr)

1.29

2.06

Fuel Nozzle

1.00 60° H

1.50 80° W

Efficiency (%)

87.1

88.5

Noise Level at 2m (dB(A))

73

73

Voltage (V)

110V 60Hz 1ph ....

110V 60Hz 1ph

Electrical Power (W)

460

800

Current Rating (A)

7.0

12.0

Weight (lb)

167

267

Length (in)

55

66

Width (in)

24

27

Height (in)

31

37

Flue Diameter (in)

6

6

Tank Capacity (gal)

14

26

Fuel Pressure (psi)

175

175

Air Lock Setting

2

5.5

APPLIANCE DESCRIPTION

Mobile space heater with:

closed combustion chamber and gas exhaust duct (indirect- fired models)

open combustion chamber (direct-fired models)

INSTALLATION INSTRUCTIONS

General instructions

The heater must be operated only by properly trained personnel. The manufacturer’s instructions must be followed.

The heater must be installed and operated so that people are not exposed to dangers deriving from exhaust gases, from the hot air flow and in such a way that no fire risks exist.

It is forbidden to install the heater in the surroundings of flammable materials, combustible products, or in places where explosion risk exist.

When the heater is used in a closed room, ensure a minimum volume of 28,300 ft³ for the HS180ID model and 53,000 ft³ for the HS300ID model and a continuous natural air circulation through windows and doors. For a good combustion, provide approximately 47 cfm air flow from outside.

For the use of the heater the general and special fire safety regulations in force in all fields of applications must be followed. In any case the following minimum safety clearances from materials or objects in the surroundings of the heater must be ensured:

Clearances:

Sides:

2.5 ft

Air inlet:

2.5 ft

Top:

6 ft

Air outlet:

12 ft

 

 

 

 

Floors and ceilings must be made of fireproof materials in the room where the heater is operated.

The air inlet and outlet must never be blocked for any reason.

Install the heater on a flat, level floor in a steady position.

It is forbidden to connect direct-fired heaters to air ducts.

Maintenance and checks

Depending on the operational conditions, usually every year, the heater should be checked by qualified personnel.

Prior to start-up, the user must check for any evident non- compliance with rules of use, safety and protection.

INSTRUCTIONS FOR USE

Start-up

The heater is factory set for operation without room thermostat.

If operation with room (remote) thermostat is desired, remove the socket cover (Fig.1, No.1) and insert the thermostat plug into the socket.

Fill the tank with proper fuel.

24

1 3

Figure 1

Connect the supply plug to a 110V ~ 60 Hz single phase earthed socket. The green lamp indicates that the heater is powered.

WARNING: THE APPLIANCE MUST BE GROUNDED

ENERCO GROUP, INC. Indirect Fired Portable Heater

3

Operating Instructions and Owner’s Manual

Image 3
Contents HS180ID HS300ID Indirect Fired Portable HeaterGeneral Hazard Warning ContentsInstructions for USE SpecificationsInstallation Instructions Appliance DescriptionMaintenance Reset after lockout and Reset of safety thermostatShut down Troubleshooting Wiring DiagramTrouble Cause Solution Fuel Solenoid Valve This page Intentionally Left Blank Limited Warranty Operating InstructionsParts Ordering Information

HS300ID, HS180ID specifications

The Enerco HS180ID and HS300ID are advanced heating solutions designed for both residential and commercial applications. As part of Enerco’s commitment to providing efficient and reliable heating products, these models incorporate cutting-edge technologies that enhance performance and user experience.

The HS180ID model is built to provide optimal heating in spaces up to 180 square feet, making it ideal for small rooms, garages, or workshops. Its powerful heating capacity ensures that it can quickly warm up any space, offering comfort even in the dead of winter. The HS300ID, on the other hand, is designed for larger spaces, providing heating for areas up to 300 square feet. This model is perfect for larger workshops, garages, and even outdoor gatherings under covered areas.

One of the standout features of both models is their energy efficiency. The Enerco HS series utilizes advanced infrared heating technology, which enables it to operate with minimal energy consumption while delivering maximum heat output. This technology ensures that the heat penetrates objects and people directly rather than just heating the air, thereby reducing wasted energy and enhancing comfort.

Both models are equipped with adjustable thermostats, allowing users to maintain their desired temperature effortlessly. The HS180ID and HS300ID also include built-in safety features, such as tip-over protection and overheating shut-off systems, ensuring peace of mind during operation. This focus on safety makes them suitable for both indoor and outdoor use.

In terms of design, the Enerco HS series features a rugged construction that is built to withstand the rigors of various environments. With their portable design, these heaters can be easily moved from one area to another, providing flexibility and convenience. The built-in carry handle further enhances portability.

Moreover, both heaters are relatively quiet, enabling them to function without disturbing daily activities. The user-friendly control panel simplifies adjustments, making it accessible for users of all ages and technological backgrounds.

In summary, the Enerco HS180ID and HS300ID heaters are versatile, efficient, and user-friendly heating solutions. With their infrared technology, energy-saving features, robust safety measures, and convenient portability, these models are excellent choices for anyone looking to maintain comfort in their living or working spaces. Whether for small or large areas, Enerco has ensured that both models deliver performance without compromising on safety and convenience.