American Dryer Corp MLG33 manual Gas Specifications for CE Approved Dryers

Models: MLG33

1 22
Download 22 pages 46.82 Kb
Page 14
Image 14

Heat Input/Gas Consumption/Orifice (Injector) Data (For Non-CE [European] Models Only)

Gas Specifications for Non-CE Approved Dryers***

Gas Type and

Supply

**Gross

Orifice Size

**Orifice

Burner

Nominal Heating Value

Pressure

Heat Input

 

 

(Injector)

Pressure

 

Btu/ft3

in WC

Btu/hr

kW

DMS

mm

Quantity

in WC

Natural

1,000

7.0-13.0

55,000

16.12

20

4.089

1

3.0

*Liquid Propane

2,500

11.0

55,000

16.12

44

2.184

1

10.0

 

 

 

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Information is per pocket/tumbler.

***Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)

Gas Specifications for CE Approved Dryers***

Gas Type and

Supply

**Gross

**Fuel

Orifice Size

**Orifice

Burner

Nominal Heating Value

Pressure

Heat Input

 

 

(Injector)

Pressure

 

 

 

 

 

Consumption

 

 

Quantity

 

 

Btu/ft3

mb

Btu/hr

kW

DMS

mm

mb

 

 

Natural (I2H/I2E)

1,000

15-30

55,000

16.12

1.557 M3/H

22

3.988

1

6.9

Natural (I2L)

830

20-35

55,000

16.12

1.876 M3/H

22

3.988

1

9.5

Natural (I2 E L L)

830

15-30

55,000

16.12

1.876 M3 /H

22

3.988

1

9.5

*Natural (I2E+)

1,000

20

55,000

16.12

1.557 M3/H

31

3.048

1

830

25

55,000

16.12

1.876 M3/H

31

3.048

1

 

*Butane (I3+)

3,175

28-30

55,000

16.12

1.162 kg/H

48

1.930

1

*Propane (I3+)

2,500

37

55,000

16.12

1.162 kg/H

48

1.930

1

Butane (I3B/P)

3,175

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

18.1

Propane (I3P )

2,500

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

24.9

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Information is per pocket/tumbler.

***Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

NOTES _____________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

14

Maytag Co.

113413 - 11

Page 14
Image 14
American Dryer Corp MLG33 manual Gas Specifications for CE Approved Dryers