Appendix
Performance Specifications
According to the ISO
| Date Transmission Cable |
|
| |
Bus Length (in m) | Resistance per | Cable Diameter | Termination (in Ω) | Max. Data Transfer |
Unit Length |
| Rate | ||
|
|
| ||
| (in mΩ/m) |
|
|
|
0...40 | < 70 | 0,25...0,34 mm² | 124 | 1000 kbit/s at 40 m |
|
| AWG23, AWG22 |
|
|
|
|
|
|
|
40...300 | < 60 | 0,34...0,6 mm² | 127 | 500 kbit/s at 100 m |
|
| AWG22, AWG20 |
|
|
|
|
|
|
|
300 ... 600 | < 40 | 0,5...0,6 mm² | 150...300* | 100 kbit/s at 500 m |
|
| AWG 20 |
|
|
|
|
|
|
|
600...1000 | < 26 | 0,75...0,8 mm² | 150...300* | 62,5 kbit/s at 1000 m |
|
| AWG 18 |
|
|
|
|
|
|
|
*With longer cables and many participants on the
The following table is meant for first assessment of necessary cable diameters for different bus lengths and
Bus Length (in m) | Number of Units on the | |||
32 | 64 | 100 | ||
| ||||
100 | 0,25 mm² bzw. AWG24 | 0,34 mm² bzw. AWG22 | 0,34 mm² bzw. AWG22 | |
|
|
|
| |
250 | 0,34 mm² bzw. AWG22 | 0,5 mm² bzw. AWG20 | 0,5 mm² bzw. AWG20 | |
|
|
|
| |
500 | 0,75 mm² bzw. AWG18 | 0,75 mm² bzw. AWG18 | 1,0 mm² bzw. AWG17 | |
|
|
|
|
Additionally, the length of branch lines - for participants that are not directly connected to the
0.3meter is still permissible. The entire length of all branch lines should not exceed 30 meters. General Note:
•As long as only short distances (up to 10 meters) are concerned, common
•The previously outlined guidelines for network cabling are mandatory as far as the rack mounted shelve interconnection or fixed installations are involved.
NetMax N8000 System Controller | 39 | |
Owner’s manual | ||
|