2 Control Elements and Connections
2.1 Front Faceplate
The front faceplate of the N8000 has level and status displays and it offers also the possibility to connect a PC via a USB interface. SIGNAL /
|
| ® |
| NETMAX |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| N8000 SYSTEM CONTROLLER | |||||||||||||||
|
|
|
| NETWORKED MATRIX SYSTEM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
AUDIO CHANNELS SLOT 1 | AUDIO CHANNELS SLOT 2 | AUDIO CHANNELS SLOT 3 | AUDIO CHANNELS SLOT 4 | NETWORK | SYSTEM STATUS | POWER | USB | ||||||||||||||||||||||||||||
|
|
|
|
|
|
|
| PEAK |
|
|
|
|
|
|
| PEAK |
|
|
|
|
|
| PEAK |
|
|
|
|
|
|
|
| ACTIVE | READY |
|
|
|
|
|
|
|
|
|
| SIGNAL |
|
|
|
|
|
|
| SIGNAL |
|
|
|
|
|
| SIGNAL |
|
|
|
|
|
|
|
| MASTER | FAULT | ON |
|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
|
|
|
SIGNAL / PEAK-LEDs
These LEDs serve as level meter display for input and output signals. The
output. The
close to the level meter’s limit. The limit is approx. at +18 dBU. The maximum level meters is +21 dBu so that there is 3 dB of head room until the final clip limit is reached. The
up sporadically in case of dynamic peaks. If the
NETWORK-LEDs
If the N8000 is operated on an audio network, e.g. CobraNet™, these LEDs show the status of the network.
The
sent or received via the network. If the LED is off, no communication via the audio network is taking place. The
named the conductor. There is always only one master in an audio network, i.e. the MASTER- LED will only be illuminated on one N8000 within the network. If the unit currently functioning as
10NetMax N8000 System Controller
Owner’s manual