Assignment of CAN plug

Preparations

Assignment of CAN plug

Pin

Name

 

Colour

T568A

 

T568B

 

 

 

2

CAN_GND

Green

 

Orange

 

 

 

 

 

4

CAN_H (+)

 

Blue

 

 

 

5

CAN_L (-)

Blue striped

 

 

 

7

MONITOR BUS +

Brown striped

 

 

 

 

8

MONITOR BUS -

 

Brown

 

 

 

 

 

The CAN-bus makes it possible to use different data transmission rates, in which the boud rate is indirectly proportional to the length of the bus. If the network is only slightly extended, higher baud rates up to 500 kbit/s are possible. In case of larger extensions, the baud rate has to be lowered (to a min. transmission rate of 10 kbit/s). The following table explains the relationship between baud rate and length of the bus or extension of the network. In principle, bus lengths over 1000 meters should only be realized with repeaters.

Transfer rate (in kbit/s)

Bus length (in m)

500

100

 

 

250

250

 

 

125

500

 

 

62,5

1000

 

 

20

2500

 

 

10

5000

 

 

Please see the CAN bus principles chapter on page 36 in the appendix of this document as well as the instruction manuals of the connected devices for further information on CAN bus (especially on system examples and performance specifications).