Network configuration
4 Network configuration
4.1 Introduction
The N8000 system controller can be connected to a
The N8000 comes with the following network configurations from the factory:
Parameter | Value |
IP address | 192.168.1.100 |
|
|
Subnet mask | 255.255.255.0 |
|
|
Gateway | 192.168.1.1 |
|
|
DHCP | deactivated |
|
|
An IP address must be unique, it must only be allocated to one single device (host) in a network. In case a new Ethernet network is designed for the operation of the N8000, it is recommended to retain the subnet mask and network ID which had been set at the factory. If the N8000 is integrated in an existing Ethernet network, the network configuration of the N8000 must be adapted.
The preset IP address of the N8000 can be retained if and only if
•only a single N8000 with
•the network ID 192.168.1 can be retained and
•no other devices have the
If at least one of these three conditions is not fulfilled, the preset IP address of the N8000 has to be changed.
Example:
The following illustration shows an example application with four NetMax N8000 in a closed network. These are networked with a PC via a central Ethernet switch. Thus, the factory preset
NetMax N8000 System Controller | 25 | |
Owner’s manual | ||
|