Electro-Voice NetMax N8000 owner manual ETHERNET Interface, RS-232Interfaces, Remote Can Bus

Models: NetMax N8000

1 48
Download 48 pages 31.71 Kb
Page 13
Image 13
ETHERNET Interface

Control Elements and Connections

N8000 automatically detects an installed network module. The module can be configured in the PC software IRIS-Net.

ATTENTION:

The N8000 has to be switched off if you want to change or install a module. You will find detailed instructions in the data sheet of the corresponding module.

ETHERNET Interface

A computer and/or other N8000 devices can be connected via the Ethernet interface for 100Base-TX / 10Base-T Ethernet networks. Normally this connection is established via a standard (straight throug) Ethernet cable and an Ethernet hub or a switch. If the N8000 is to be connected

directly with a computer or another N8000, a crossed Ethernet cable (crossover cable) must be used.

RS-232 Interfaces

The N8000 can be connected to external devices, such as

multimedia system (AMX™, Crestron™) or facility

management systems via the two RS-232 interfaces. All

N8000 functions and parameters can be controlled and

monitored via RS-232. Communication is done using an

ASCII parser which is easy to implement. Thus, a NetMax

system can be easily combined with media and touch panel

RS-232 InterfacesREMOTE CAN BUSManual backgroundManual backgroundManual backgroundcontrol systems. A PC can also be connected to the RS-232 port to access N8000 parameters using a terminal program like Hyperterminal. A special instruction set is available in order to establish a connection to a

PROMATRIX/PROANNOUNCE system. The two RS-232 ports can be configured according to their corresponding application via the IRIS-Net PC software.

REMOTE CAN BUS

Electro-Voice remote amplifiers and other devices with CAN interfaces can be connected to the N8000 via the CAN interface. Up to 100 remote amplifiers can be connected with a single N8000. All connected components are linked to the NetMax monitoring and control platform.

The STATUS-LED is provided to monitor the communication on the CAN bus. If the CAN interface is not in use, the LED is deactivated. In normal mode the LED flashes every 2

NetMax N8000 System Controller

13

Owner’s manual

 

Page 13
Image 13
Electro-Voice NetMax N8000 ETHERNET Interface, RS-232Interfaces, Remote Can Bus, Control Elements and Connections