Probe Operation
Restarting the Probe
95
Cold Start
A cold start resets all of the probe’s measurement data as well as all alarm, event,
filter, and user-defined statistics conf i guration to their default values . Basic
communications configuration parameters (IP address, default gateway IP
address, and subnet mask) are not reset.
You can cold start the probe by doing one of the following:
Pressing the CONFIG Button twice within one second.
Selecting the menu item Cold start and Exit from the probe’s Main Menu
when you have a local terminal connected to the probe, as described on
page 96.
Using Agilent NetMetrix to execute a probe cold start. Refer to your
NetMetrix documentation for details.
Table5-1 on page 92 shows which data and parameters are reset during a cold
start or warm start of the probe.
Pressing the CONFIG Button Twice
Pressing the CONFIG button twice within one second causes the probe to cold
start.