Probe Operation

Restarting the Probe

93

*PPP refers to PPP, HDLC, or SDLC.

Cycling Power

A power outage or cycling power to the probe causes a warm start. The probe

does not have a power switch; therefore, cycling the power consists of

disconnecting and reconnecting the power cord.

Probe
Configuration
Parameters
Trap destination table Saved Reset
Serial connection table Saved Reset
Serial configuration information for
outgoing connections, such as: dial
strings.
Saved Reset
Time period for utilization calculations Saved Saved
Other Serial configuration informatio n,
such as: SLIP address and subnet mask,
serial port speed, modem initialization
strings, and Flow Control.
Saved Saved
Probe configuration information, such as:
IP address, default gateway, and subnet
mask.
Saved Saved
TFTP server address Saved Saved
Download filename Saved Saved
Time zone Saved Saved
Security Settings Saved Saved
Interface Status Saved Saved
Crash data (used by Agilent support) Saved S aved
Category Probe Memory Contents War m St art
Status Cold Start
Status

Table 5-1: Probe Data and Parameters Reset by Warm or Cold Start (Continued)