Local Terminal Configuration

Using the Main Menu

Using the Main Menu

 

 

To configure the probe, connect a terminal directly to the probe and use the probe

 

 

Main Menu.

 

 

 

NOTE

The probe is not available to the network when you are using the configuration

 

 

menus.

 

 

 

To view the probe Main Menu:

1.Connect a terminal or a personal computer (PC) emulating a terminal to the probe RS-232 connector using a null modem cable. Refer to Appendix A, “Cables and Connectors” on page 113 for more information on cables.

2.Configure the terminal for 8 bits/character, 1 stop bit, no parity, Xon/Xoff handshaking, and a baud rate of 9600.

3.Connect the power cord to the probe and to a power source (either 100-120/ VAC or 220-240/VAC). The probe does not have a power switch, but is turned on by connecting to a power source.