Probe Operation
Restarting the Probe
94
Selecting the Warm Start Menu Item
Use the following procedure to warm start the probe using the probe’s Main
Menu:
1. Connect a local terminal (or a PC emulating a terminal) to the probe. Refer
to “Local Terminal Configuration and Installation” on page 4 for
information on connecting a local terminal.
2. Press the CONFIG button once (on the back of the probe) to place the probe
into the configuration mode. Use a narrow, pointed object (like a pen) to
press the recessed CONFIG button. The probe then displays its Main Menu
on the terminal. Figure 5-1 shows the probe’s Main Menu.
3. Press 7 to execute a warm start and exit the probe’s Main Menu. The wa rm
start occurs immediately. The Activity and Fa ult LEDs ar e t urn ed on during
a warm start. When the warm start comple tes, the Activity LED flashes to
indicate traffic (if present), the Fault LED turns off, and the ~Line On (or
Power) LED is on.
Main Menu - Revision
1.Modify/View configuration values ->
2.Modify/View security values ->
3.Modify/View interface values ->
4.Display interface summary
5.TFTP Download new firmware ->
6.XMODEM Download new firmware ->
7.Warm start and Exit
8.Cold start and Exit

Figure 5-1: Probe Main Menu