Probe Operation

Restarting the Probe

Selecting the Warm Start Menu Item

Use the following procedure to warm start the probe using the probe’s Main Menu:

1.Connect a local terminal (or a PC emulating a terminal) to the probe. Refer to “Local Terminal Configuration and Installation” on page 4 for information on connecting a local terminal.

2.Press the CONFIG button once (on the back of the probe) to place the probe into the configuration mode. Use a narrow, pointed object (like a pen) to press the recessed CONFIG button. The probe then displays its Main Menu on the terminal. Figure 5-1 shows the probe’s Main Menu.

Main Menu - Revision

1.Modify/View configuration values -> 2.Modify/View security values -> 3.Modify/View interface values -> 4.Display interface summary

5.TFTP Download new firmware -> 6.XMODEM Download new firmware -> 7.Warm start and Exit

8.Cold start and Exit

Figure 5-1: Probe Main Menu

3.Press 7 to execute a warm start and exit the probe’s Main Menu. The warm start occurs immediately. The Activity and Fault LEDs are turned on during a warm start. When the warm start completes, the Activity LED flashes to indicate traffic (if present), the Fault LED turns off, and the ~Line On (or Power) LED is on.