Probe Operation
Restarting the Probe
Selecting the Warm Start Menu Item
Use the following procedure to warm start the probe using the probe’s Main Menu:
1.Connect a local terminal (or a PC emulating a terminal) to the probe. Refer to “Local Terminal Configuration and Installation” on page 4 for information on connecting a local terminal.
2.Press the CONFIG button once (on the back of the probe) to place the probe into the configuration mode. Use a narrow, pointed object (like a pen) to press the recessed CONFIG button. The probe then displays its Main Menu on the terminal. Figure
Main Menu - Revision
1.Modify/View configuration values
5.TFTP Download new firmware
8.Cold start and Exit
Figure 5-1: Probe Main Menu
3.Press 7 to execute a warm start and exit the probe’s Main Menu. The warm start occurs immediately. The Activity and Fault LEDs are turned on during a warm start. When the warm start completes, the Activity LED flashes to indicate traffic (if present), the Fault LED turns off, and the ~Line On (or Power) LED is on.
94