HIGH VOLTAGE COMPONENTS

33

1

2

3

4

5

6

H

G

F

E

D

C

B

A

CN-F

AH SENSOR

 

 

 

 

 

 

 

 

MAGNETRON

HIGH VOLTAGE COMPONENTS

1 BLK

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 RED

 

 

 

 

OVEN LAMP

 

 

 

 

 

FUSE

 

MAGNETRON

 

 

 

 

 

 

 

3 WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

& SOCKET

 

 

 

 

BLK

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

DOOR

GRN

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

SENSING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

GRY

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.O.

 

 

WHT

 

 

 

 

 

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORG

NOTE:

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

GRN

Hot (YLW & PNK) wire

 

PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

must be connected to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

terminal with blue mark

BLUE MARK

 

 

 

 

 

 

 

 

 

 

HIGH VOLTAGE

 

 

 

 

 

on the oven light socket.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITOR

 

 

 

 

 

BLK

 

 

 

 

 

 

 

ORG

 

POWER TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL PANEL

 

 

 

 

 

 

 

 

 

 

W

G

 

 

 

 

 

 

 

 

 

 

 

MONITOR FUSE

 

 

 

 

 

 

 

H

R

NOTE:

 

 

 

 

 

 

 

 

 

& FUSE HOLDER

 

 

 

 

 

 

 

T

Y

 

 

 

 

 

CN-G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot (ORG) wire must be connected to the

 

 

 

 

 

 

 

 

N.O. DAMPER

 

 

 

 

power transformer terminal nearest to the

 

 

 

 

 

 

 

 

 

 

 

 

transformer mounting screw.

 

 

IC-1

 

 

 

 

 

PNK

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DAMPER

 

 

 

 

FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHT

ORG

 

 

 

 

 

 

 

OVEN

 

 

 

CN-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMAL

 

 

 

 

GRY

 

 

 

 

 

WHT

 

 

 

 

 

 

 

 

3

 

 

MONITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

CUT-OUT

 

6 PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 PNK

 

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

1

 

 

ORG

 

 

 

 

 

 

 

 

W W

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN-F

 

4 RED

 

 

 

 

 

 

 

 

 

 

H

H

P

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN-E

3 RED

 

 

 

 

 

 

 

 

 

 

 

T

T

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM.

6

2 GRN

 

COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

1 ORG

 

 

 

 

 

 

HEATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY3

4

 

 

 

 

 

 

 

ELEMENT

CONVECTION MOTOR

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.O.

RY3 (COM.)

BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

GRY

 

 

 

 

 

 

 

 

COM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

RY3 (N.O.)

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY2

 

RY2 (COM.)

BRN

 

 

 

 

 

 

 

 

 

BRN

 

 

 

 

 

 

 

 

N.O.

 

BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

COM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

G

G

 

 

 

 

 

 

 

 

 

ORG

 

 

 

 

 

 

 

 

 

The

grounding

conductor

of

 

 

 

 

 

 

 

E

 

R

R

 

 

 

 

 

 

RY2 (N.O.)

 

 

 

 

 

 

 

 

 

the

power

supply cord

has

RY1

 

 

 

 

 

 

D

 

Y

Y

 

 

 

 

 

ORG

 

 

 

 

 

 

 

 

 

been

grounded

by power

 

 

 

 

 

 

 

 

 

 

 

N.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply cord fixing screw.

 

 

 

RY1 (COM.)

BLK

 

 

 

 

 

 

 

 

 

 

 

 

The screw must be kept

 

 

 

BRN

 

 

 

 

 

 

 

 

 

 

 

 

allways tight.

 

 

 

RY5

 

RY1 (N.O.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN-A

 

 

 

 

 

 

 

 

 

 

 

 

PNK

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

N.O.

 

 

H

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

T1

1 ORG

 

 

 

 

 

 

 

 

PNK

 

 

 

 

 

 

 

 

 

7

 

2

 

 

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

 

 

 

 

 

 

 

 

9

 

3 BRN

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN-A

 

 

 

 

 

 

 

 

 

 

OUTER CASE

The neutral (WHT) wire

 

 

 

RY6

 

5 PPL

 

 

 

 

THERMISTOR

 

 

must

be

connected

to

 

 

 

 

 

TURNTABLE

 

 

 

SWITCH

 

 

 

 

 

 

 

 

the

terminal with

"N"

 

 

 

 

 

6

 

 

MOTOR

 

 

 

 

 

 

 

(Oven side)

 

 

 

 

 

 

 

 

 

 

RED 2

RED

 

 

mark

on

the power

 

 

 

 

 

7

 

 

 

 

 

 

 

 

N.O.

supply cord.

 

 

 

 

 

 

 

 

 

 

 

 

 

RED 1

RED

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

POWER SUPPLY CORD

 

 

9 WHT

 

N.O. WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRY

COM

 

 

 

 

120V 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

GRY

 

 

 

 

 

 

 

OUTER CASE

 

 

 

 

 

 

 

 

 

 

 

 

SECONDARY

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Cabinet side)

 

 

 

 

 

 

 

 

 

 

 

 

INTERLOCK

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure S-1. Pictorial Diagram

 

 

 

 

 

 

 

 

 

H

 

G

 

F

E

 

 

 

D

 

 

C

 

B

 

 

 

 

 

A

 

1

2

3

4

5

6

R-930AK R-930AW

Page 35
Image 35
Sharp R-930AW service manual Figure S-1. Pictorial Diagram, High Voltage Components, Control Panel