Field Controls UV-18X Indication for USE, II. General Information, III. Installation

Page 2

I.INDICATION FOR USE

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition.

II.GENERAL INFORMATION

There are different size units available, depending on the square footage of your home. See chart below for determining your homes needs.

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Air

 

 

Lamp Intensity at 1

 

 

Recommended

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Duct

 

Volts

 

 

Amps

 

 

Hz

 

 

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp °F

 

 

meter

 

 

Max Sq. Feet

 

 

 

 

Width

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UV-18X

14

120

 

1.0

 

60

 

60

 

190°

 

 

2@73 μW/cm2

4000

 

WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have units unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UVC light from any source.

WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier.

WARNING: Designed for a closed duct system. Do not mount near a return air opening.

WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). For use on gas fired, oil fired, electric and split system heat pump forced air systems*. This product is NOT designed to be mounted outside on gas fired or heat pump packaged units**.

*Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units.

**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building

III.INSTALLATION

1.Locate a suitable location for the unit downstream from the ‘A’ coil in the supply plenum or in the return plenum; preferably downstream from the air filter. For optimum “cleaning” effect on the ‘A’ coil, mount the unit in the supply plenum as close as possible to the ‘A’ coil. (See Figure 1)

Figure 1

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.

Page 2

Image 2
Contents Safety Considerations Items Included in KITII. General Information III. InstallationIndication for USE For flex duct applications, refer to on Flat Bracket Installation Angled Bracket InstallationPage Diagram B IV. Bulb Mounting Bracket Selection and InstallationDiagram a VII. Troubleshooting Guide MaintenanceVI. Replacement Procedure VIII. Replacement Parts ListIX. Flex Duct Installation Provisions