Goodman Mfg GME8 service manual Thermostats Filters

Page 9

PRODUCT DESIGN

Thermostats:

NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets.

Filters:

Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty.

Upflow Filters

This furnace has provisions for the installation of return air filters at the side and/or bottom return. The furnace will accommodate the following filter sizes depending on cabinet size:

Side Return(s)

 

Cabinet

Nominal

Approx.

 

 

Width

Filter Size

Flow Area

 

 

(in.)

(in.)

(in2)

 

 

 

 

 

 

 

All

16 x 25 x 1

400

 

 

 

 

 

 

 

 

 

 

 

Bottom Return

Cabinet

Nominal

Approx.

Width

Filter Size

Flow Area

(in.)

(in.)

(in2)

 

 

 

17-1/2

14 x 25 x 1

350

 

 

 

21

16 x 25 x 1

400

 

 

 

Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in the duct system such as a central return.

MINIMUM FILTER SIZES

FURNACE INPUT

FILTER SIZE

TYPE

45M

160 in2

permanent

70M

241 in2

permanent

90M

320 in2

permanent

115M

400 in2

permanent

140M

370 in2

permanent

45M

320 in2

disposable

70M

483 in2

disposable

90M

640 in2

disposable

115M

800 in2

disposable

140M

738 in2

disposable

PERMANENT NOMINAL 600 F.M. FACE VELOCITY

DISPOSABLE NOMINAL 300 F.M. FACE VELOCITY

9

Image 9
Contents Technical Manual 070 Product IdentificationGME80703BXC GME80905CXC GME81155CXC General Operation Product DesignAccessibility Clearances Minimum Product Dimensions Primary Limit 1824 Thermostats Filters Dual$aver Configuration & Operation GME80703BXC GME80905CXC GME81155CXC Furnace SpecificationsBlower Performance Blower Performance SpecificationsBlower BR BR Wiring Diagrams GME8CADLY Wiring Diagrams GME8CBSchematics