WIRING DIAGRAMS | GME8_CB |
WARNING:DISCONNECTPOWERBEFORE
SERVICING.WIRINGTOUNITMUSTBE
PROPERLYPOLARIZEDANDGROUNDED.
24VAC
HUMIDIFIER
| C | G R W Y |
|
|
|
|
|
|
|
| Y |
|
|
|
|
|
|
|
| L | |||
|
|
|
|
|
|
| D |
| |||
|
|
|
|
|
|
|
| G |
|
| |
|
|
|
|
|
|
| T |
|
|
| |
|
|
|
|
|
| S |
|
|
|
| |
|
|
|
|
| D |
|
|
|
|
| |
|
| AUTO | 5MIN | N |
|
|
|
|
|
| |
|
| 2 |
|
|
|
|
|
|
| ||
|
| 1STG | 2STG | MODE |
|
|
| ||||
|
| 150SEC | 100SEC | HT |
|
|
|
|
|
| |
|
|
|
|
| O |
|
|
|
|
| |
10 | 11 | 12 |
|
|
| FF | DLY | ||||
WH |
|
|
|
|
| ||||||
7 | 8 | 9 |
|
| BL |
|
|
| |||
|
|
|
|
|
| ||||||
4 | 5 | 6 |
|
|
|
| DIAGNOSTIC LED |
| |||
|
| FUSE |
|
|
|
|
| ||||
1 | 2 | 3 |
|
|
|
|
| ||||
|
| SEENOTE6 |
|
|
|
| |||||
|
|
| BR |
|
|
|
| ||||
|
| INTEGRATED |
|
|
|
|
|
|
|
|
|
|
| CONTROLMODULE |
|
|
| HIHEAT- |
|
|
| ||
|
| FS |
|
|
|
|
|
| |||
|
|
|
|
|
| H |
|
|
| ||
RD RD |
| BL |
|
|
|
|
|
|
|
|
|
|
| RD |
|
|
|
|
|
|
|
|
|
AUXILIARY
LIMITS
BR
|
|
| HUMIDIFIER | INTEGRATED | |
|
|
|
|
| CONTROLMODULE |
|
|
| XFMR(6) | GND |
|
|
|
|
|
| |
|
|
| GND(8) | C2 |
|
|
|
| MVC(9) | GAS | |
|
|
| MVH(12) | HI | VALVE |
|
|
|
|
| |
|
|
| MVL(2) | M1 | |
| C |
|
| IDBLOWER | |
|
|
|
| ||
|
|
|
| AUXILIARY | PRESSURE |
24VTHERMOSTATCONNECTIONS |
|
|
| LIMITCONTROLS | SWITCH |
G |
| PS(10) | C | NO | |
Y | TO | PSO(4) |
|
| |
|
|
| |||
|
|
|
| ||
|
| MICRO HLI(7) |
|
| |
| W |
| HLO(1) |
|
|
|
|
|
|
| |
|
|
|
|
| AUTORESET |
| R |
|
|
| PRIMARY |
|
| RO2(11) |
| LIMIT | |
|
|
|
| ||
|
|
|
|
| CONTROL |
|
|
| RO1(5) |
|
|
|
|
|
| MANUALRESETROLLOUT | |
|
|
|
| LIMITCONTROL(S) |
|
|
| XFMR(3) | (SINGLECONTROLONSOMEMODELS) | ||
|
|
| 24VAC |
| |
|
|
|
|
| |
|
|
|
| 40VA |
|
|
|
|
| TRANSFORMER |
HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
COOL |
| PU |
|
| |
| LINENEUTRAL | 2 | OR | |
YL YL | 1 | |||
| ||||
| WH |
| ||
PU |
|
| PARK | |
|
|
|
| BK |
|
| BK | 24V |
|
|
|
| 115V |
|
|
|
| XFMR |
|
|
| WH |
|
|
| WH(N) | BK(HI) BL(MEDHI) OR(MED) RD(MEDLOW) YL(LOW) |
BR BL WH | BLOWER | CIRCULATOR |
INTEGRATEDCONTROLMODULE
FP
IGN
IND
115VACXFMR-N
FLAMESENSOR
HOTSURFACE
IGNITER
ID
BLWR
HL EAO T-
H
| ||||
H |
|
| BLWR | |
I |
|
| ||
| T |
|
| |
A |
|
| ||
E |
|
|
|
|
H |
|
|
|
|
INTEGRATEDCONTROLMODULE
|
| BK |
| GR |
|
WH | BK | DOORSWITCH |
| SWITCHLOCATEDINBLOWER | |
| COMPARTMENTONSOMEMODELS | |
| RD | RD |
WH | WH | PRIMARYLIMIT |
| RD | |
| YL | |
|
| |
|
| YL |
|
| BR |
|
| BL |
|
| WH |
PM C HI
|
|
|
| ELECTRONIC |
| |
15PINPLUG |
|
| AIRCLEANER | |||
ONSOMEMODELS |
|
|
|
|
| |
BLOWERCOMPARTMENT |
|
| ||||
BURNERCOMPARTMENT |
| JUNCTIONBOX |
| |||
|
|
|
| |||
| 24VAC |
| DOOR |
|
|
|
| HUMIDIFIER | SWITCH |
|
|
| |
NO | C |
|
|
|
|
|
OR |
|
| WARNING: |
|
|
|
|
| DISCONNECTPOWER |
|
| ||
YL PRESSURE | YL |
| DISCONNECT | |||
BEFORESERVICING. |
|
|
| |||
SWITCH |
| WIRINGTOUNIT |
|
|
| |
|
|
| MUSTBE |
|
|
|
|
|
| PROPERLY |
|
|
|
| WH |
| POLARIZED |
|
|
|
BK |
| ANDGROUNDED. | L | GND | N | |
|
|
| ||||
|
|
| OVERCURRENTPROTECTIONDEVICE | |||
BK |
|
|
|
|
|
|
|
|
| JUNCTION |
|
|
|
HOT
1 3 2
W | BOX |
H |
|
SURFACE 2STAGE
IGNITER GASVALVE (HONEYWELL)
PU
PU PU
ROLLOUTLIMITS
(SINGLECONTROLONSOMEMODELS)
|
| |
|
| GND |
|
| LINEH |
| INDUCEDDRAFT |
|
| BLOWER | TO115VAC/1/60HZ |
|
| |
FLAME |
| POWERSUPPLYWITH |
| OVERCURRENTPROTECTION | |
SENSOR |
| |
| DEVICE | |
|
|
0STEADYON=NORMALOPERATION
| OFF =CONTROLFAILURE | |
1 | 1FLASH = | SYSTEMLOCKOUT(RETRIES/RECYCLESEXCEEDED) |
2 | 2FLASHES=PRESSURESWITCHSTUCKCLOSED | |
3 | 3FLASHES=PRESSURESWITCHSTUCKOPEN | |
4 | 4FLASHES=OPENHIGHLIMIT | |
5 | 5FLASHES=FLAMESENSEWITHOUTGASVALVE | |
6 | 6FLASHES= OPENROLLOUTOROPENFUSE | |
7 | 7FLASHES=LOWFLAMESIGNAL | |
8 | 8FLASHES=CHECKIGNITERORIMPROPERGROUND | |
C | RAPIDFLASHES=REVERSED115VACPOLARITY/VERIFYGND |
LOWVOLTAGE(24V)
LOWVOLTAGEFIELD
HIVOLTAGE(115V)
HIVOLTAGEFIELD
JUNCTION
TERMINAL
INTERNALTO INTEGRATEDCONTROL
PLUGCONNECTION
EQUIPMENTGND
FIELDGND
FIELDSPLICE
SWITCH(TEMP.)
IGNITER
SWITCH(PRESS.)
OVERCURRENT
PROT.DEVICE
|
| NOTES: |
| |
COLORCODES: | PKPINK | 1.SETHEATANTICIPATORONROOMTHERMOSTATAT0.7AMPS. |
| |
2.MANUFACTURER'SSPECIFIEDREPLACEMENTPARTSMUSTBEUSEDWHENSERVICING. |
| |||
YL YELLOW | BRBROWN |
| ||
3.IFANYOFTHEORIGINALWIREASSUPPLIEDWITHTHEFURNACEMUSTBEREPLACED,ITMUSTBEREPLACEDWITH | ||||
OR ORANGE | WH WHITE | WIRINGMATERIALHAVINGATEMPERATURERATINGOFATLEAST105°C.USECOPPER | CONDUCTORSONLY. | |
PUPURPLE | BLBLUE | 4.BLOWERSPEEDSSHOULDBEADJUSTEDBYINSTALLERTOMATCHTHEINSTALLATIONREQUIREMENTSSOASTO | ||
PROVIDETHECORRECTHEATINGTEMPERATURERISEANDTHECORRECTCOOLINGCFM.(SEESPECSHEETFORAIR | ||||
GRGREEN | GYGRAY | |||
FLOWCHART) |
| |||
BKBLACK | RD RED | 5.UNITMUSTBEPERMANENTLYGROUNDEDANDCONFORMTON.E.C.ANDLOCALCODES. |
| |
|
| 6.TORECALLTHELAST5FAULTS,MOSTRECENTTOLEASTRECENT,DEPRESSSWITCHFORMORETHAN2SECONDS | ||
|
| WHILEINSTANDBY(NOTHERMOSTATINPUTS). |
|
0140F00658 REV.A
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most
15