The EL180UHE unit is shipped ready for installation in the upflow or horizontal right position (for horizontal left posi­ tion the combustion air pressure switch must be moved) fueled by natural gas. A conversion kit (ordered separate­ ly) is required for use in LP/Propane gas applications. The furnace is shipped with the bottom panel in place. The bot­ tom panel must be removed if the unit is to be installed in a horizontal application. The panel may also be removed in upflow applications.

Shipping and Packing List

Package 1 of 1 contains

1 - Assembled EL180UHE unit

1 - Bag assembly containing the following:

2 - Screws

1- Snap bushing

1- Snap plug

1- Wire tie

1- Vent warning label

1- Owner's manual and warranty card

The following items may be ordered separately: 1 - Thermostat

1 - Suspension kit (for horizontal installations)

1 - LP/Propane changeover kit

1 - Return air base

1 - High altitude kit

1 - Side filter kit

Check equipment for shipping damage. If you find any damage, immediately contact the last carrier.

Safety Information

DANGER

Danger of explosion.

There are circumstances in which odorant used with LP/propane gas can lose its scent. In case of a leak, LP/propane gas will settle close to the floor and may be difficult to smell. An LP/propane leak detector should be installed in all LP applications.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, person­ al injury or loss of life. Installation and service must be performed by a licensed professional installer (or equivalent), service agency or the gas supplier.

CAUTION

As with any mechanical equipment, personal injury can result from contact with sharp sheet metal edges. Be careful when you handle this equipment.

Certifications

EL180UHE units are CSA International certified to ANSI Z21.47.

In the USA, installation of gas furnaces must conform with local building codes. In the absence of local codes, units must be installed according to the current National Fuel Gas Code (ANSI‐Z223.1). The National Fuel Gas Code is available from the following address:

American National Standards Institute, Inc. 11 West 42nd Street

New York, NY 10036

Clearances

Adequate clearance must be made around the air open­ ings into the vestibule area. In order to ensure proper unit operation, combustion and ventilation air supply must be provided according to the current National Fuel Gas Code.

Vent installations must be consistent with the National Fuel Gas Code venting tables (in this instruction) and applicable provisions of local building codes.

This furnace is CSA International certified for installation clearances to combustible material as listed on the unit nameplate and in the tables in figures 7 and 11. Accessibility and service clearances must take precedence over fire protection clearances.

NOTE - For installation on combustible floors, the furnace shall not be installed directly on carpeting, tile, or other combustible material other than wood flooring.

Installed Locations

For installation in a residential garage, the furnace must be installed so that the burner(s) and the ignition source are located no less than 18 inches (457 mm) above the floor. The furnace must be located or protected to avoid physical damage by vehicles. When a furnace is installed in a public garage, hangar, or other building that has a haz­ ardous atmosphere, the furnace must be installed accord­ ing to recommended good practice requirements and cur­ rent National Fuel Gas Code.

Temperature Rise

NOTE - Furnace must be adjusted to obtain a temperature rise within the range specified on the unit nameplate. Failure to do so may cause erratic limit operation and may result in premature heat exchanger failure.

This EL180UHE furnace must be installed so that its elec­ trical components are protected from water.

Page 3

Image 3
Contents Table of Contents Installation Instructions EL180UHEOpening Unit Dimensions inches mmSafety Information EL180UHE Gas FurnaceShipping and Packing List Installed in Combination with a Cooling Coil Use of Furnace as Construction HeaterGeneral Unconfined Space Combustion, Dilution & Ventilation AirConfined Space Air from InsideAir from Outside Equipment in Confined Space Upflow Applications Setting EquipmentReturn Air -- Upflow Applications With transition and filterSingle Side Return Air Removing the Bottom Panel Horizontal ApplicationsReturn Air -- Horizontal Applications Supply Air Plenum Horizontal Application Unit Installed on PlatformFilters Duct SystemUpflow Position VentingReturn Air Plenum Mounting Screws LocationSide Vent Discharge Horizontal Left PositionLeft Side Vent Discharge Right Side Vent DischargeVenting Using a Masonry Chimney Horizontal Right PositionSide Vent Discharge no modifications necessary Vent Connection Upflow and Horizontal Position Common Venting Using Metal-Lined Masonry ChimneyConnector Diameter Maximum Horizontal Connector Length feet mGeneral Venting Requirements Page MIN FAN + FAN FAN + NAT Gas Piping Removal of the Furnace from Common VentGas Supply 103.92 97.69 92.31 Gas Pipe Capacity ft3/hr m3/hrLeak Check Horizontal Applications Possible Gas Piping ConfigurationsPrecautions and Procedures ElectricalThermostat Interior MAKE-UP BOX InstallationAccessory Terminals Generator Use Voltage RequirementsEL180UHE Schematic Wiring Diagram Automatic Hot Surface Ignition System Diagnostic Codes / Status of FurnaceIntegrated Control Integrated ControlUnit Start-Up For Your Safety Read Before LightingHigh Altitude Gas Pressure AdjustmentGAS Meter Clocking Chart Proper CombustionOther Unit Adjustments Service Blower Parts Repair Parts ListML180UHE Burner Assembly & Removal Control Panel PartsStart-Up & Performance Check List Unit Operation Cooling ModeTemperature Drop Temperature Rise

EL180UHE specifications

Lennox International Inc. has long been a leader in providing innovative heating and cooling solutions, and the EL180UHE represents a notable advancement in their line of high-efficiency gas furnaces. Designed to meet the demands of residential heating, this unit combines advanced technology with user-friendly operation and significant energy savings.

One of the standout features of the EL180UHE is its efficiency rating, with an Annual Fuel Utilization Efficiency (AFUE) of up to 80%. This high efficiency not only helps homeowners save on energy bills but also reduces their carbon footprint. The furnace is equipped with a reliable, multi-speed blower motor, which enhances comfort levels by maintaining consistent air circulation throughout the home.

The EL180UHE employs advanced combustion technologies, such as Lennox's low-NOx burner, which minimizes nitrogen oxide emissions, contributing to a cleaner environment. The unit is also designed with a sealed combustion system that draws air directly from the outdoors rather than from inside the home, leading to improved indoor air quality and increased safety.

Another significant characteristic of the EL180UHE is its whisper-quiet operation. This is achieved through well-engineered insulation and a design that minimizes noise levels, allowing for a comfortable living environment without disruptive sounds. Many homeowners appreciate the quiet performance, especially during the night or in spaces where noise is a concern.

The installation process is straightforward, supported by Lennox's user-friendly design. The EL180UHE is compatible with various home configurations and can easily integrate with existing HVAC systems. Additionally, it has a compact footprint, making it suitable for homes with space constraints.

Further enhancing its appeal, this gas furnace features robust warranty options, reflecting Lennox's commitment to quality and customer satisfaction. Homeowners can rest assured that they are investing in a durable product that has been built to last.

In conclusion, Lennox International Inc.'s EL180UHE gas furnace exemplifies the company's dedication to innovation, efficiency, and reliability in home heating solutions. With its high AFUE rating, advanced combustion technology, quiet operation, and user-friendly design, the EL180UHE is an excellent choice for homeowners looking to enhance their comfort while minimizing energy costs.