Johnson Controls 356486-UUM-E-0109 warranty Section I Safety, Table of Contents

Page 1

USER’S INFORMATION MANUAL

MODELS:

All Residential Multi-position Gas Furnaces

(33” Models)

EFFICIENCY

RATING

CERTIFIED

ISO 9001

Certified Quality

Management System

TABLE OF CONTENTS

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

INSTRUCTIONS FOR EXAMINING THE

FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 START-UP AND SHUTDOWN INSTRUCTIONS . . . . . . . . . . . . . . . . 3 HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . 3 OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 TO TURN OFF THE APPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . . 4

FURNACE MAINTENANCE - USER INFORMATION . . . . . . . . . . . . 4 EXTERNAL AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

How to Clean your Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 BLOWER CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 MOTOR LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

SERVICE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 TROUBLESHOOTING PROBLEMS . . . . . . . . . . . . . . . . . . . . . . . . .5 FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . .5 FURNACE MAINTENANCE - DEALER/CONTACTOR . . . . . . . . . . .5 REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

CONTACT INFORMATION

Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions.

Contact us by mail:

Johnson Controls Unitary Products

Consumer Relations

5005 York Drive

Norman, OK 73069

We recommend that the user read all sections of this manual and keep the manual for future reference.

FIRE OR EXPLOSION HAZARD - Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone (includ- ing cell phone) in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service agency or the gas supplier.

SECTION I: SAFETY

This is a safety alert symbol. When you see this symbol on labels or in manuals, be alert to the potential for personal

injury.

Understand and pay particular attention to the signal words DANGER, WARNING, or CAUTION.

DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury.

WARNING indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation, which, if not avoided may result in minor or moderate injury. It is also used to alert against unsafe practices and hazards involving only property dam- age.

1.The furnace area must be kept clear and free of combustible mate- rials, gasoline and other flammable vapors and liquids.

2.Insulating materials may be combustible. The furnace must be kept free and clear of insulating materials. The furnace area must be examined when installed in an attic or other insulated space or when insulation is added to be sure that the insulation material has been kept away from the furnace.

3.The furnace needs air for combustion in order to operate properly and safely. Do not block or obstruct air openings on the furnace, air openings to the area where the furnace is installed, or spaces around the furnace.

4.Follow the instructions exactly as shown on the OPERATING INSTRUCTION LABEL on the furnace or the “START-UP AND SHUTDOWN INSTRUCTIONS” section of this manual when light- ing the furnace or turning the furnace off.

5.Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the furnace before shutting off the electrical supply.

6.Do not use this furnace if any part has been under water. A flood- damaged furnace is extremely dangerous. Attempts to use the fur- nace can result in fire or explosion. A qualified service agency should be contacted to inspect the furnace and replace all gas controls, control system parts, electrical parts that have been wet or the furnace if deemed necessary.

7.NEVER . . .Store flammable materials of any kind near your fur- nace. Gasoline, solvents, and other volatile liquids should be stored only in approved containers outside your home. These materials vaporize easily and are extremely dangerous.

8.NEVER . . .Store cleaning materials near your furnace. Materials such as bleaches, detergents, powdered cleansers, etc., can cause corrosion of the heat exchangers.

9.NEVER . . . Use the area around your furnace as a storage area for items which could block the normal flow of air. This flow of air is required for ventilation of the various furnace components.

356486-UUM-E-0109

Image 1
Contents Table of Contents Section I SafetyContact Information ECM Motor PSC MotorPSC Motor ECM Motor Section III START-UP and Shutdown InstructionsHOW Your GAS Furnace Works Operating Instructions Section IV Furnace Maintenance User InformationTo Turn OFF the Appliance External AIR FiltersSection V Service Information Exclusions Limited Warranty

356486-UUM-E-0109 specifications

Johnson Controls is a reputed global leader in building technologies and solutions, and one of their innovative products is the Johnson Controls 356486-UUM-E-0109. This device is an advanced controller designed specifically for enhanced building management and energy efficiency.

The 356486-UUM-E-0109 is engineered for seamless integration within existing building management systems, making it an ideal choice for new or retrofitted setups. One of its main features is its digital control capabilities, which allow for precise monitoring and management of various building systems such as HVAC, lighting, and security. Through its sophisticated algorithms, the controller optimizes energy consumption, ensuring that buildings run efficiently while reducing operational costs.

In terms of technology, the 356486-UUM-E-0109 utilizes state-of-the-art communication protocols, including BACnet and LonWorks. These protocols ensure interoperability with various devices from different manufacturers, which is crucial for modern smart buildings. The controller also supports both wired and wireless connectivity, providing flexibility in installation and communication.

Another key characteristic of the 356486-UUM-E-0109 is its intuitive user interface. It features a user-friendly touchscreen display that simplifies navigation and programming, allowing facility managers to easily monitor system operations. The device also provides real-time data analytics and reporting capabilities, empowering users to make informed decisions based on comprehensive insights into energy usage and system performance.

Furthermore, the 356486-UUM-E-0109 is designed with reliability and durability in mind. Built from high-quality materials, it is capable of withstanding various environmental conditions, making it suitable for diverse applications across different sectors, from commercial buildings to industrial facilities.

In summary, the Johnson Controls 356486-UUM-E-0109 is a powerful controller that enhances building management with its advanced digital capabilities, interoperability with other systems, and user-friendly interface. Its focus on energy efficiency, real-time data analytics, and robust construction makes it a valuable asset for any facility seeking to optimize operations and reduce costs.