Thermostat Chart

Group

- AC

AC10 2 Stage Scroll A/C w/ Variable Speed Furnace - PV8/9; (F,L)*8/9V, (G,L)*8/9V, XYG8V-*, XYF8V-*, XYG9V-*, XYF9V-*

 

THERMOSTAT

THERMOSTAT

THERMOSTAT

THERMOSTAT

THERMOSTAT

 

 

VARIABLE SPEED

 

 

TWO STAGE

 

 

 

*DN22U00124

*PP32U70124

*DN22C00124

*DP22U70124

*PP32U71124

 

 

FURNACE CONTROL

 

 

AIR CONDITIONING

 

 

 

 

 

 

 

*PP32U72124

 

 

 

 

 

 

 

 

 

 

C

C

C

C

C

 

 

C

 

 

 

C

 

 

 

24-Volt Common

24-Volt Common

24-Volt Common

24-Volt Common

24-Volt Common

 

 

24-Volt Common

 

 

24-Volt Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

Y

Y

Y1

Y1

 

 

Y1

 

 

 

Y1

 

 

 

First Stage Cool

First Stage Cool

First Stage Cool

First Stage Cool

First Stage Cool

 

 

First Stage Cool

 

 

First Stage Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y2

Y2

Y2

Y2

Y2

 

 

Y/Y2

 

 

 

Y2

 

 

 

Second Stage Cool

Second Stage Cool

Second Stage Cool

Second Stage Cool

Second Stage Cool

 

 

Single/Second Stage Cool

 

 

Second Stage Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

R

R

R

R

 

 

R

 

 

 

R

 

 

 

24-Volt Hot (Heat XFMR)

24-Volt Hot (Heat XFMR)

24-Volt Hot

24-Volt Hot

24-Volt Hot

 

 

24-Volt Hot

 

 

24-Volt Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RC

RC

 

 

 

 

 

 

 

 

 

 

 

 

 

24-Volt Hot (Cool XFMR)

24-Volt Hot (Cool XFMR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E/W1

E/W1

W

E/W1

E/W1

 

 

W/W1

 

 

 

 

 

 

 

First Stage Heat

First Stage Heat

First Stage Heat

First Stage Heat

First Stage Heat

 

 

Single/First Stage Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W2

W2

W2

W2

W2

 

 

W2

 

 

 

 

 

 

 

Second Stage Heat

Second Stage Heat

Second Stage Heat

Second Stage Heat

Second Stage Heat

 

 

Second Stage Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

G

G

G

G

 

 

G

 

 

 

 

 

 

 

Fan

Fan

Fan

Fan

Fan

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM CONTROL

 

 

 

 

 

 

 

 

 

 

 

DHM

 

 

HUM

 

 

 

 

 

 

 

 

 

 

 

Dehumidistat

 

 

Dehumidification - Open on Humidity Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

(O)

 

 

 

 

 

 

 

 

 

 

 

Malfunction Light

 

 

Reversing Valve– Energized in Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HM

 

 

(X/L)

 

 

 

 

 

 

 

 

 

 

 

Humidistat

 

 

Malfunction Light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comfort Alert

 

 

 

 

 

 

 

 

 

 

 

 

 

Interface

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in the Product

For additional

Catalog Section.

connection diagrams

 

for all UPG equipment refer to “Low Voltage System Wiring”

5

Connection of the "C"

Connection of the "C"

Connection of the "C"

Connection of the "C" Termainal,

Step 1 of Thermostat User

Termainal, 24-Volt

Termainal, 24-Volt

Termainal, 24-Volt Common,

24-Volt

Configuration Menu must be

Common, is optional

Common, is optional

is optional

Common, is optional

set to MLTI STG

when used with batteries

when used with batteries

when used with batteries

when used with batteries

 

 

 

 

 

 

Thermostat Installer Setup

Thermostat Installer

 

 

Step 16 of Thermostat

Setup Number 0170 -

 

Step 1 of Thermostat User

Number 1 - System Type -

 

User Configuration Menu

System Type - must be

 

Configuration Menu

must be set to 6 - 2

 

must be set to ON to use

set to 8 - 2 Heat/2 Cool

 

must be set to MS 2

Heat/2 Cool Conventional

 

Comfort Alert Features

Multistage Conventional

 

 

 

 

 

 

 

 

 

 

 

Thermostat Installer Setup

 

 

 

E2/P Switch must be in

 

 

 

the E2 position and the

Number 15 - Compressor

 

 

 

 

 

 

Humidistat Jumper on

Protection - must be set to 5

 

 

 

 

 

 

CFM Control must be

 

 

 

 

 

 

 

 

in the 'YES' position

 

 

 

 

 

 

 

 

for Dehumidification

 

 

 

 

 

24V HUMIDIFIER

(Optional)

( ) CONVENIENCE TERMINAL

NO FUNCTION IN THIS APPLICATION.

document available online at www.upgnet.com

246786-CTG-B-0407

Image 5
Contents Features WarrantyDescription Natural GASInput Output Nominal Cabinet Total Unit Electrical and Performance DataAfue Air TempUnitary Products Group AIR Flow DataHigh / LOW Speed Cooling and Heat Pump CFM Without Filters High / LOW Heat CFM Without FiltersApplying Filter Pressure Drop to Determine System Airflow Filter PerformanceFilter Sizes Filter Performance Pressure Drop Inches W.CFor additional Unitary ProductsCatalog Section Thermostat Variable Speed TWO StageFurnace Control Heat Pump Chart HPCTG-B-0407 Unitary Products Group Accessories Copyright by York International Corp . All rights reserved

FC9V specifications

The Coleman FC9V is a highly versatile and robust camping stove that has gained popularity among outdoor enthusiasts and casual campers alike. Known for its reliability and performance, this stove makes cooking in the great outdoors both convenient and enjoyable.

One of the standout features of the Coleman FC9V is its Compact design. The stove can easily fit inside most camping gear, making it an ideal choice for those limited on space. Despite its portability, it does not compromise on functionality. Its design allows for efficient heat distribution, ensuring that meals cook evenly and quickly.

The FC9V utilizes Coleman’s innovative Instant Lighting technology, which means that users can start cooking with the push of a button. This feature is particularly beneficial when time is of the essence or when conditions are less than ideal. The durable burner construction ensures that the stove can withstand the rigors of outdoor use, providing users confidence that it will perform well, even in varying weather conditions.

Another characteristic that makes the Coleman FC9V a favorite is its adjustable heat settings. The stove features a precise control knob, allowing users to easily regulate the temperature, from simmering delicate sauces to boiling water for meals. This control over heat levels is essential for cooking a variety of dishes while camping.

The Coleman's Wind Block technology is another significant advantage. This feature involves windscreen barriers that shield the flames from gusts, ensuring consistent cooking, even in breezy conditions. This is invaluable for maintaining performance when camping in exposed locations.

Additionally, the FC9V comes equipped with a sturdy base that provides stability on uneven surfaces, enhancing safety during cooking. Its user-friendly design allows for easy setup and takedown, making it an appealing choice for campers of all experience levels.

Finally, the Coleman FC9V is compatible with a range of fuel types, allowing for flexibility depending on user preference or availability. Whether you choose propane, butane, or another fuel source, this stove's adaptability ensures that you can always have a cooking solution at hand.

Overall, the Coleman FC9V is a remarkable camping stove that delivers on reliability, safety, and ease of use, making it an essential piece of gear for outdoor adventures. Whether cooking up simple meals or more elaborate dishes, this stove stands out as a dependable companion in the wild.