Coleman FC9V Electrical and Performance Data, Input Output Nominal Cabinet Total Unit, Afue

Page 2

246786-CTG-B-0407

 

 

 

 

 

 

 

22-3/4

 

 

 

 

 

 

 

7/8

 

 

A

 

 

 

 

 

 

 

 

 

 

 

7/8

T-STAT WIRING 7/8” K.O.

 

 

 

 

 

 

HORIZONTAL CONDENSATE

 

 

 

T-STAT WIRING 7/8” K.O.

 

 

 

 

 

 

 

13-7/8

 

DRAIN OPENING 1-3/4”

 

 

 

 

 

 

 

 

 

 

 

HORIZONTAL CONDENSATE

 

 

 

 

 

 

DRAIN OPENING 1-3/4”

HORIZONTAL CONDENSATE

 

 

 

40

 

HORIZONTAL

 

DRAIN OPENING 2”

 

 

 

 

 

 

 

 

 

 

 

CONDENSATE

 

 

 

 

 

 

 

 

JUNCTION BOX

 

29

 

 

29

DRAIN OPENING 1-3/4”

HOLE 7/8”

 

 

 

 

 

 

 

 

 

22-3/4

 

 

22-3/4

JUNCTION BOX

 

GAS PIPE ENTRY 1-1/2”

 

 

 

 

HOLE 7/8”

 

 

 

 

 

 

 

 

21-5/8

 

 

 

 

 

 

 

 

 

21-1/4

GAS PIPE

 

CONDENSATE DRAIN

 

18-1/2

 

 

18-1/2

 

 

 

 

ENTRY 1-1/2”

 

HOLE 7/8”

 

 

 

 

 

 

 

SIDE PIPING HOLE 3-3/8”

 

11-3/4

 

 

9-1/8

 

 

7-1/2

 

 

 

 

 

 

 

8-1/2

CONDENSATE DRAIN

 

 

 

 

 

HOLE 7/8”

 

 

2-1/4

 

 

 

 

 

 

 

 

 

 

 

 

22-1/4

 

 

FRONT

 

 

 

 

25-3/8

 

 

 

 

 

 

 

26-1/2

 

 

 

 

 

 

 

27-1/8

 

 

 

 

 

 

 

30-1/8

 

23-11/16

 

 

23-5/8

RIGHT SIDE

 

 

 

 

 

 

 

 

 

 

1-1/4

 

5/8

 

LEFT SIDE

 

19-1/4

 

 

 

 

 

 

 

 

 

 

1-1/4

 

D

 

5/8

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

B

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

2-1/4

 

 

 

 

 

 

 

 

 

23-1/4

 

 

 

 

BOTTOM IMAGE

 

 

TOP IMAGE

 

 

 

 

SUPPLY END

 

 

RETURN END

 

 

DIMENSIONS

 

 

 

 

 

 

 

Models

Nominal

Cabinet

 

 

Cabinet Dimension

 

 

CFM

Size

A (in.)

B (in.)

C (in.)

D (in.)

E (IN.)

 

FC9V060B12DH11

1200

B

17-1/2

16-1/4

15

1-3/4

2-3/8

FC9V080B12DH11

1200

B

17-1/2

16-1/4

15

1-3/4

2-3/8

FC9V080C16DH11

1600

C

21

19-3/4

18-1/2

2-1/8

2-3/4

FC9V100C20DH11

2000

C

21

19-3/4

18-1/2

2-1/8

2-3/4

FC9V120D20DH11

2000

D

24-1/2

23-1/4

22

2-1/2

3

ELECTRICAL AND PERFORMANCE DATA

 

Input

Output

Nominal

Cabinet

Total Unit

AFUE

Air Temp.

Models

(High/Low)

(High/Low)

Airflow

Width

Rise

 

 

 

 

 

 

 

 

 

 

 

 

MBH

MBH

 

CFM

In.

Amps

%

°F

FC9V060B12DH11

60 / 39

56 / 36

 

1200

17-1/2

9

92

35 - 65

FC9V080B12DH11

80 / 52

75 / 49

 

1200

17-1/2

9

92

35 - 65

FC9V080C16DH11

80 / 52

75 / 49

 

1600

21

12

92

35 - 65

FC9V100C20DH11

100 / 65

93 / 61

 

2000

21

14

92

35 - 65

FC9V120D20DH11

120 / 78

112 / 74

 

2000

24-1/2

14

92

35 - 65

 

 

 

 

 

 

 

 

 

 

 

Input

Max. Outlet

Blower

Blower

Max.

Min. Wire Size *

Operating

Models

(High/Low)

Air Temp.

Size

Over-current

(awg) @ 75 ft.

Weight

 

 

 

 

 

 

 

 

 

 

Protect

One Way

 

 

MBH

°F

HP

 

Amps

In.

Lbs.

FC9V060B12DH11

60 / 39

165

1/2

 

7.0

11 x 8

20

14

136

FC9V080B12DH11

80 / 52

165

1/2

 

7.0

11 x 8

20

14

143

FC9V080C16DH11

80 / 52

165

3/4

 

10.2

11 x 10

20

14

159

FC9V100C20DH11

100 / 65

165

1

 

12.7

11 x 11

20

12

164

FC9V120D20DH11

120 / 78

165

1

 

12.7

11 x 11

20

12

182

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.

Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.

* Wire size and overcurrent protection must comply with the National Electric Code.

NOTES:

1.For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.

2.Wire size based on copper conductors, 60°C, 3% voltage drop.

3.Continuous return air temperature must not be below 55°F.

4.All filters must be high velocity cleanable type.

2

Unitary Products Group

Image 2
Contents Description WarrantyFeatures Natural GASAfue Electrical and Performance DataInput Output Nominal Cabinet Total Unit Air TempHigh / LOW Speed Cooling and Heat Pump CFM Without Filters AIR Flow DataUnitary Products Group High / LOW Heat CFM Without FiltersFilter Sizes Filter PerformanceApplying Filter Pressure Drop to Determine System Airflow Filter Performance Pressure Drop Inches W.CCatalog Section Unitary ProductsFor additional Thermostat Variable Speed TWO StageFurnace Control Heat Pump Chart HPCTG-B-0407 Unitary Products Group Accessories Copyright by York International Corp . All rights reserved

FC9V specifications

The Coleman FC9V is a highly versatile and robust camping stove that has gained popularity among outdoor enthusiasts and casual campers alike. Known for its reliability and performance, this stove makes cooking in the great outdoors both convenient and enjoyable.

One of the standout features of the Coleman FC9V is its Compact design. The stove can easily fit inside most camping gear, making it an ideal choice for those limited on space. Despite its portability, it does not compromise on functionality. Its design allows for efficient heat distribution, ensuring that meals cook evenly and quickly.

The FC9V utilizes Coleman’s innovative Instant Lighting technology, which means that users can start cooking with the push of a button. This feature is particularly beneficial when time is of the essence or when conditions are less than ideal. The durable burner construction ensures that the stove can withstand the rigors of outdoor use, providing users confidence that it will perform well, even in varying weather conditions.

Another characteristic that makes the Coleman FC9V a favorite is its adjustable heat settings. The stove features a precise control knob, allowing users to easily regulate the temperature, from simmering delicate sauces to boiling water for meals. This control over heat levels is essential for cooking a variety of dishes while camping.

The Coleman's Wind Block technology is another significant advantage. This feature involves windscreen barriers that shield the flames from gusts, ensuring consistent cooking, even in breezy conditions. This is invaluable for maintaining performance when camping in exposed locations.

Additionally, the FC9V comes equipped with a sturdy base that provides stability on uneven surfaces, enhancing safety during cooking. Its user-friendly design allows for easy setup and takedown, making it an appealing choice for campers of all experience levels.

Finally, the Coleman FC9V is compatible with a range of fuel types, allowing for flexibility depending on user preference or availability. Whether you choose propane, butane, or another fuel source, this stove's adaptability ensures that you can always have a cooking solution at hand.

Overall, the Coleman FC9V is a remarkable camping stove that delivers on reliability, safety, and ease of use, making it an essential piece of gear for outdoor adventures. Whether cooking up simple meals or more elaborate dishes, this stove stands out as a dependable companion in the wild.