Coleman FC9V warranty CTG-B-0407 Unitary Products Group, Chart HP, Furnace Control Heat Pump

Page 6

6

Thermostat

 

Chart - HP

HP24 Two Stage H/P - H*5B, YZE - w/Variable 2 Stage Furnace, 2 Stage Cooling Ready - PV8/9, (F,L)*8/9V, (G,L)*8/9V, XYG8V-*, XYF8V-*, XYG9V-*, XYF9V-*

W/031-01996- Series Demand Control; Hot Heat Pump Mode OR Conventional

 

THERMOSTAT

THERMOSTAT

THERMOSTAT

 

 

VARIABLE SPEED

TWO STAGE

 

 

*PP32U70124

*DN22H00124

*PP32U71124

 

 

FURNACE CONTROL

HEAT PUMP

 

 

 

*DP22U70124

*PP32U72124

 

 

 

 

 

 

 

 

 

C

C

C

 

 

C

 

 

C

 

 

24-Volt Common

24-Volt Common

24-Volt Common

 

 

24-Volt Common

 

 

24-Volt Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

Y1

Y1

 

 

Y1

 

 

Y1

 

 

First Stage Heat/Cool

First Stage Heat/Cool

First Stage Heat/Cool

 

 

First Stage Cool

 

 

First Stage Heat/Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RC

 

 

 

 

Y/Y2

 

 

Y2 OUT

 

 

24-Volt Hot (Cool XFMR)

 

 

 

 

Single/Second Stage Cool

 

 

Second Stage Cool Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

R

R

 

 

R

 

 

R

 

 

24-Volt Hot (Heat XFMR)

24-Volt Hot

24-Volt Hot

 

 

24-Volt Hot

 

 

24-Volt Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

W/W1

 

 

W1 OUT

 

 

Emergency Heat

 

 

 

 

Single/First Stage Heat

 

 

First Stage Auxiliary Heat Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W2

W2

 

 

W2

 

 

W2 OUT

 

 

 

Second Stage Auxiliary Heat

Second Stage Auxiliary Heat

 

 

Second Stage Heat

 

 

Second Stage Auxiliary Heat Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

G

G

 

 

G

 

 

 

 

 

Fan

Fan

Fan

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM CONTROL

 

 

 

O/B

O

O

 

 

(O)

 

 

O

 

 

Reversing Valve

Reversing Valve–Energized in Cool

Reversing Valve–Energized in Cool

 

 

Reversing Valve–Energized in Cool

 

 

Reversing Valve–Energized in Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

L

L

 

 

(X/L)

 

 

X/L

 

 

Malfunction Light

Malfunction Light

Malfunction Light

 

 

Malfunction Light

 

 

Malfunction Light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y2

Y2

Y2

 

 

(Y 2)

 

 

Y2

 

 

Second Stage Heat/Cool

Second Stage Heat/Cool

Second Stage Heat/Cool

 

 

 

 

Second Stage Heat/Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DHM

 

 

HUM

 

 

 

 

 

 

 

Dehumidistat

 

 

Dehumidification - Open on Humidity Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUX

E/W1

E/W1

 

 

 

 

 

 

W

 

 

Auxiliary Heat

First Stage Auxiliary Heat

First Stage Auxiliary Heat

 

 

 

 

 

 

Auxiliary Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HM

 

 

 

 

 

 

BSG

 

 

 

 

Humidistat

 

 

 

 

 

 

Bonnet Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bonnet Sensor (Optional)

 

BS

 

 

 

 

 

 

 

 

 

Bonnet Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

246786-CTG-B-0407

Unitary Products Group

 

 

 

 

24V HUMIDIFIER

 

 

 

 

 

(Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat Installer Setup Number

0170 -

Selection of GAS/ELEC switch

Step 1 of Thermostat User Configuration

 

 

 

System Type - must be set to

 

 

Set W2 Delay on furnace to OFF

 

on thermostat not necessary

Menu must be set to Heat Pump 2

 

12 - 3 Heat/2 Cool Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat Installer Setup Number

0190 -

Step 1 of Thermostat User

E2/P Switch must be in the E2 position

 

 

 

and the Humidistat Jumper on CFM

 

( ) CONVENIENCE TERMINAL. NO

Reversing Valve (O/B) Operation - must be

Configuration Menu must be

 

Control must be in the 'YES' position for

 

FUNCTION IN THIS APPLICATION.

set to 0 - O/B Terminal Energized in Cooling

set to Heat Pump 2

 

Dehumidification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat Installer Setup Number

0200 -

 

 

 

 

 

Backup Heat Source - must be set to

1 - Heat

 

 

 

 

 

Pump Backup Heat Source is Fossil Fuel

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat Installer Setup Number

0210 -

 

 

 

 

 

External Fossil Fuel Kit - must be set to 0 -

 

 

 

 

 

External Fossil Fuel Kit is Controlling Heat

 

 

 

 

 

Pump Backup Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

Change FFuel Jumper on

Heat Pump to ON

Image 6
Contents Description WarrantyFeatures Natural GASAfue Electrical and Performance DataInput Output Nominal Cabinet Total Unit Air TempHigh / LOW Speed Cooling and Heat Pump CFM Without Filters AIR Flow DataUnitary Products Group High / LOW Heat CFM Without FiltersFilter Sizes Filter PerformanceApplying Filter Pressure Drop to Determine System Airflow Filter Performance Pressure Drop Inches W.CCatalog Section Unitary ProductsFor additional Thermostat Variable Speed TWO StageChart HP CTG-B-0407 Unitary Products GroupFurnace Control Heat Pump Accessories Copyright by York International Corp . All rights reserved

FC9V specifications

The Coleman FC9V is a highly versatile and robust camping stove that has gained popularity among outdoor enthusiasts and casual campers alike. Known for its reliability and performance, this stove makes cooking in the great outdoors both convenient and enjoyable.

One of the standout features of the Coleman FC9V is its Compact design. The stove can easily fit inside most camping gear, making it an ideal choice for those limited on space. Despite its portability, it does not compromise on functionality. Its design allows for efficient heat distribution, ensuring that meals cook evenly and quickly.

The FC9V utilizes Coleman’s innovative Instant Lighting technology, which means that users can start cooking with the push of a button. This feature is particularly beneficial when time is of the essence or when conditions are less than ideal. The durable burner construction ensures that the stove can withstand the rigors of outdoor use, providing users confidence that it will perform well, even in varying weather conditions.

Another characteristic that makes the Coleman FC9V a favorite is its adjustable heat settings. The stove features a precise control knob, allowing users to easily regulate the temperature, from simmering delicate sauces to boiling water for meals. This control over heat levels is essential for cooking a variety of dishes while camping.

The Coleman's Wind Block technology is another significant advantage. This feature involves windscreen barriers that shield the flames from gusts, ensuring consistent cooking, even in breezy conditions. This is invaluable for maintaining performance when camping in exposed locations.