Amana AMH* service manual Wiring Diagrams AMH8CA/CB, Humidifier

Page 15

WIRING DIAGRAMS

AMH8_CA/CB

HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

WARNING:DISCONNECT POWER BEFORE

SERVICING.WIRING TO UNIT MUST BE

PROPERLY POLARIZED AND GROUNDED.

24VAC

HUMIDIFIER

C G R W Y

5 MIN

2 STG MODE

7

8

WH

BL

4

5

6

1

2

3

 

 

 

 

 

BR

 

AUXILIARY

 

 

 

 

 

 

 

LIMITS

 

 

 

 

 

INTEGRATED

 

 

 

 

 

 

 

CONTROL MODULE

 

 

 

 

RD

RD

 

RD

BL

 

BR

 

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

OR

 

 

 

 

YL

YL

 

1

 

 

 

 

 

 

 

 

 

 

 

 

BK(HI) BL(MED) OR(MEDLOW) RD(LOW)

 

PU

 

WH

 

 

BK

 

WH(N)

 

 

 

 

 

 

PARK

 

 

 

 

 

 

 

BK

 

24V

BR WH BL

CICULATOR BLOWER

 

 

 

 

 

 

 

115V

CAP

BR BR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XFMR

 

 

 

 

 

 

 

WH

 

 

 

 

 

 

 

 

 

 

BK

15 PIN PLUG

 

 

 

 

GR

 

 

 

 

 

 

 

 

 

ON SOME MODELS

 

 

 

 

 

 

 

BLOWER COMPARTMENT

 

 

 

 

 

 

BURNER COMPARTMENT

 

WH

BK

 

 

DOOR SWITCH

 

 

24 VAC

 

 

 

 

 

HUMIDIFIER

 

 

 

SWITCH LOCATED IN BLOWER

 

 

 

 

 

 

 

COMPARTMENT ON SOME MODELS

 

NO

C

 

 

 

 

RD

 

RD

OR

 

 

 

 

WH

WH

 

 

 

YL

PRESSURE

YL

 

 

 

PRIMARY LIMIT

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

WH

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

BR

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

WH

BK

 

 

 

 

 

PM

C

HI

 

 

 

 

 

 

 

 

 

 

 

HOT

1

2

3

WH

 

 

 

 

 

 

 

 

 

 

 

 

 

SURFACE

2 STAGE

 

 

 

 

 

 

IGNITER

GAS VALVE

 

 

 

 

 

 

 

PU

 

 

INDUCED DRAFT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER

 

 

 

PU

 

 

PU

FLAME

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR ROLLOUT LIMITS

(SINGLE CONTROL ON SOME MODELS)

 

 

 

 

 

HUMIDIFIER

INTEGRATED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL MODULE

 

 

 

XFMR (6)

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

GND (8)

 

 

 

 

 

 

 

 

C2

 

 

 

 

 

 

 

 

 

MVC (9)

 

 

 

 

 

 

 

 

GAS

 

 

 

 

MVH (12)

 

 

 

 

 

 

 

 

HI

VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MVL (2)

 

 

 

 

 

 

 

 

M1

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

ID BLOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE

 

24V

G

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

PS (10)

 

 

 

 

 

 

 

C

 

NO

 

THERMOSTAT

Y

TO

PSO (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HLI (7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MICRO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

HLO (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTIONS

R

 

RO2 (11)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RO1 (5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XFMR (3)

 

 

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40 VA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

XFMR-H

 

 

 

 

 

 

 

 

 

 

115 VAC

 

XFMR-N

 

 

 

 

 

 

 

 

FLAME SENSOR

 

 

 

 

 

 

 

 

 

FP

 

 

HOT SURFACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGNITER

 

 

 

 

 

 

 

INTEGRATEDCONTROLMODULE

 

IGN

 

 

 

 

 

 

 

 

IGN-N

INTEGRATEDCONTROLMODULE

 

 

 

 

 

 

 

 

ID

 

 

 

 

 

 

 

 

IND

 

 

 

 

 

 

BLWR

IND-N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CIRCULATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLWR

CIR-N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRONIC

 

 

 

 

 

 

 

 

 

EAC-H

 

 

AIR CLEANER

EAC-N

 

 

 

LINE-H

 

 

 

 

 

 

 

 

 

 

 

 

LINE-N

 

 

 

 

 

 

 

 

JUNCTION BOX

 

 

 

 

 

 

 

DOOR

SWITCH

DISCONNECT

 

L GND

N

TO 115VAC/ 1

Ø /60 HZ POWER SUPPLY WITH

OVERCURRENT PROTECTION DEVICE

JUNCTION

BOX

LINE-N

GND

LINE H

TO 115 VAC/ 1/60HZ

POWER SUPPLY WITH

OVERCURRENT PROTECTION

DEVICE

0 STEADY ON = NORMAL OPERATION

OFF = CONTROL FAILURE

11 FLASH = SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) 2 2 FLASHES = PRESSURE SWITCH STUCK CLOSED

3 3 FLASHES = PRESSURE SWITCH STUCK OPEN

4 4 FLASHES = OPEN HIGH LIMIT

5 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

6 6 FLASHES = OPEN ROLLOUT OR OPEN FUSE

7 7 FLASHES = LOW FLAME SIGNAL

8 8 FLASHES = CHECK IGNITER OR IMPROPER GROUND

C RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND

LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL

INTERNAL TO

INTEGRATED CONTROL

PLUG CONNECTION

EQUIPMENT GND FIELD GND FIELD SPLICE SWITCH (TEMP.) IGNITER

SWITCH (PRESS.)

OVERCURRENT PROT. DEVICE

COLOR CODES:

PK PINK

YL YELLOW

BR BROWN

OR ORANGE

WH WHITE

PU PURPLE

BL BLUE

GR GREEN

GY GRAY

BK BLACK

RD RED

NOTES:

1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE

REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C. USE COPPER CONDUCTORS ONLY.

4.BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART)

5.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

6.TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS).

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

15

Image 15
Contents Technical Manual 070 Product IdentificationDo not connect or use any device General Operation Product DesignAccessibility Clearances Minimum Upflow/Horizontal Component IdentificationAMH8 Product DimensionsAuxiliary Limit Switches 1824 Thermostats TwinComfort Configuration & Operation Model Furnace SpecificationsCFM & Temperature Rise vs. External Static Pressure Blower Performance SpecificationsBlower Humidifier Wiring Diagrams AMH8CA/CBRD RD Wiring Diagrams AMH8CCSchematics

AMH* specifications

The Amana AMH* series is a line of advanced air conditioning and heating systems designed to provide efficient climate control for residential spaces. Renowned for their innovative features and technology, these systems prioritize comfort, sustainability, and ease of use.

One of the standout features of the Amana AMH* series is its impressive energy efficiency. The units are equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, which indicate their ability to provide effective cooling while consuming less energy. This not only helps homeowners save on utility bills but also reduces their environmental impact, making the AMH* series an eco-friendly choice for climate control.

The Amana AMH* series incorporates state-of-the-art inverter technology. This technology allows the system to adjust its cooling or heating output based on the specific demands of the home at any given moment. Instead of operating at a single, fixed speed, the inverter-driven compressor can modulate its output, providing a more consistent temperature and improving overall comfort.

Additionally, these systems feature advanced refrigerant technology. They often utilize R-410A refrigerant, which is known for being more environmentally friendly compared to older refrigerants. This contributes to the overall efficiency of the units while minimizing harmful emissions, complying with modern environmental regulations.

Another notable characteristic of the Amana AMH* series is its noise level. Designed with sound insulation and advanced engineering, these units operate quietly, ensuring that the comfort of the indoor environment is not disrupted by excessive noise. This is particularly beneficial in residential settings where quiet operation is essential.

The user-friendly controls of the Amana AMH* systems make them easy to operate. Many units come with smart technology that allows homeowners to control their HVAC system remotely via smartphones or tablets. This feature not only enhances convenience but also allows for better management of energy consumption, further promoting efficiency.

Moreover, Amana products are known for their durability and reliability. Backed by a robust warranty, these systems are built with high-quality materials and components, ensuring they can withstand the test of time and varying weather conditions.

In conclusion, the Amana AMH* series represents a blend of energy efficiency, innovative technology, and user-friendly features, making it an excellent choice for homeowners seeking reliable and effective climate control solutions. With a focus on sustainability, comfort, and quiet operation, the AMH* series stands out as a leader in the HVAC market.