Garage Furnaces
Model Number | Btu/hr | Btu/hr | Efficiency % |
| Dimensions |
| Maximum | Type | Shipping Weight | |||
|
| Input | Output |
|
|
|
|
|
| Wall | of | |
Natural | Propane | Thermal | AFUE | Width | Depth |
| Height | (lbs.) | ||||
Rating | Rating |
| Thickness* | Control | ||||||||
1403622 | 1403621 | 14,000 | 10,039 | 76.0 | 63.0 | 18" | 7⅛" |
| 26¾" | 24" | Millivolt Wall | 56 |
2203622 | 2203621 | 22,000 | 16,462 | 75.0 | 67.0 | 32⅛" | 10¼" |
| 28" | 24" | Millivolt Wall | 98 |
3003622 | 3003621 | 30,000 | 21,849 | 73.0 | 66.0 | 32⅛" | 10¼" |
| 28" | 24" | Millivolt Wall | 100 |
|
|
|
|
|
| Conversion Kit Available | ||||||
4007332‡ | 4007331‡ | 40,000 | 32,000 | 80.0 | 75.0 | 14⅛" | 11¾" |
| 77⅜" | 24" | 24V Wall | 126 |
4007732 | 4007731 | 40,000 | 32,000 | 80.0 | 75.0 | 14⅛" | 11¾" |
| 77⅜" | 24" | 24V Wall | 126 |
5507332‡ | 5507331‡ | 55,000 | 44,000 | 80.0 | 76.0 | 14⅛" | 11¾" |
| 87" | 24" | 24V Wall | 140 |
6257732 | 6257731 | 65,500 | 50,000 | 80.0 | 76.0 | 14⅛" | 11¾" |
| 87" | 24" | 24V Wall | 140 |
|
|
| All models have ½" gas connection · All models are rated for 4,500' elevation. |
|
*Venting shipped with furnace for
‡Intermittent ignition
Features
Direct-Vent Safety
Air Circulation Pattern | COMBUSION | |
| PRODUCTS | |
WARM ROOM AIR | VENTED | |
TO OUTSIDE | ||
|
RADIANT EXT
For clean, comfortable heat when and where you want it. The gas flame is completely sealed inside, away from all contact with room air. Air necessary for combustion is drawn into the chamber from outside through direct
Accessories
|
| ||
Blower is easily added to the furnace. Comes with a fully automatic fan switch. |
| ||
115V power supply required · 6 lbs. |
| ||
Model 2302 for 22,000 and 30,000 Btu/hr |
| ||
Model 2303 for 14,000 Btu/hr | 2302 | ||
Side Outlet Accessories - Allows heat to be ducted into a side room. | |||
| |||
6801 | |||
6802 |
|
| |
Front Diffusing Grilles |
| ||
A |
|
HEAT
INSIDE
COMBUSION
AIR FROM
OUTSIDE
wall vent, and all combustion products are vented directly to the outside. Only clean, gentle heat, in
counterflow models only. |
| |
6703 |
| |
6704 | 6703 | |
Venting Accessories |
| |
4318 | Vent Shield Deflector · Insulated, galvanized metal sheet · 4 lbs. |
|
COOL ROOM AIR
OUTSIDE
continuous circulation is delivered into the room. Windows and doors can stay closed because no room air is used for combustion.
9301 | 15" Vent Extension for 22 and 30,000 Btu/hr Furnaces · 7 lbs. |
| |
9302 | 24" Vent Extension for 22,000 Btu/hr Furnaces · 10 lbs. |
| |
9303 | 24" Vent Extension for 14 and 30,000 Btu/hr Furnaces · 10 lbs. |
| |
9304 | 15" Vent Extension for 14,000 Btu/hr Furnaces · 7 lbs. | 4318 | |
9307 | Thin Wall Collar · Wall thicknesses from 1" to 5" · 4 lbs. |
| |
|
| ||
9308 | Vent Cap Guard · Protects pedestrian traffic from heat of the vent cap · 3 lbs. |
| |
9806 | Counterflow |
|
"Matchless" Pilot Igniter
All models include a "matchless" pilot igniter and a glass observation door. Assures convenient pilot lighting without matches.
Automatic Thermostat - Included with all Models
Contemporary Finish
Light,
"Bird Guard"
All vent caps include
9807 | Counterflow |
9808 | Counterflow |
Finish Items
4701 Trim Strip Accessory · Metal finish moulding strips painted the same color as the furnace · 4 lbs.
Conversion Kits - Current models only · 1 lb.
Btu Size | Natural to | Propane to |
| |
Propane | Natural |
| ||
14,000 | 8925 | 8928 |
| |
| ||||
22,000 | 8926 | 8929 |
| |
30,000 | 8927 | 8930 |
| |
40,000 | 7686 | 7693 |
| |
55,000 | 7688 | 7695 | 8925 | |
62,500 | 7689 | 7696 | ||
|
|
|
|
| High Altitude Models |
|
|
| ||||||
| Dimensions and Clearances |
|
|
| |||||||||
| Hard Wire Adapter - | Model 9940 |
|
| |||||||||
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 2" from intersecting wall |
|
|
|
|
|
|
|
|
|
|
|
|
| 18" from top of appliance to ceiling/overhang for 14,000 Btu/hr models |
|
|
|
|
|
|
|
|
|
|
| |
| 24" from top of appliance to ceiling/overhang for 22,000 and 30,000 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Important |
|
| ||||
| Btu/hr models |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| · | Read owner's manual before using/installing. |
|
| |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| · | Photographs are representative. |
|
| ||
| 4" from intersecting wall |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| · | Check local codes and ordinances for permitted uses. |
|
| |
| 4" from top of appliance to ceiling/overhang |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| · | Consult installation manual for clearances prior to installation. |
| |||
| 0" to finished floor |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| · | We reserve the right to amend product specifications without notice. |
| ||
| 18" from centerline of vent cap on all sides |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| · | Installation and servicing recommended by a qualified service person. |
| |||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| · | Venting must comply with the installation manual. |
|
|
|
|
|
|
|
|
|
|
|
| · | New York approval |
| |
| 250 West Laurel Street · Colton, California 92324 USA |
|
| · | Massachusetts approval |
|
| ||||||
|
|
| · | Please read the warranty for any limitations for disclaimers. |
| ||||||||
| (909) | (909) |
|
|
| ||||||||
|
|
| · | Combustion chamber carries a |
| ||||||||
| Homeowner Assistance: (909) |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| parts carry a |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| © 2006 Williams Furnace Co. | Printed in U.S.A. |
|
| All Rights Reserved | L1171 5/06 |