Williams 4003532, 2503532 Wiring Diagrams Replacement, Parts, Service Hints, Technical Service

Page 19

OWNER’S MANUAL

WIRING DIAGRAMS

REPLACEMENT

 

 

 

 

 

Thermostat

 

 

 

 

 

Red

White

 

 

 

Junction

 

 

Black

 

 

Box

 

 

 

 

 

 

 

 

 

V.A.C.

 

 

 

Black

Black

Green

 

 

 

 

 

Terminal Block

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit

Sail Switch

 

Switch

 

 

Red

Black

 

Time Delay

 

Green

 

Brown

Relay

 

 

Orange

Yellow

 

 

 

Blue

 

1

 

2

Ignition

3

Control

Board

4

5 (Open)

6

PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

All parts listed herein may be ordered from your equipment supplier.

When ordering repair parts, always give the following information:

 

Black

 

 

Yellow

Transformer

 

 

 

 

Brown

 

 

 

 

 

 

370 V.A.C.

 

 

 

Capacitor

 

 

 

 

5 MFD

Yellow

Gas Valve

 

White

 

 

 

 

White

 

Brown

 

 

 

 

 

 

 

Brown

 

White

 

White

Brown

Black

 

 

Motor

 

Note:

 

 

Green

 

 

7

Black

Black Probe

White

White

Glo-Bar

model number of your furnace

type of gas, natural or propane/LP

the replacement part number and de- scription

SERVICE HINTS

When Gas Pressure Is Too Low

glo-bar glows, but burner will not ignite

Figure 20 - Wiring Diagram (25,000 BTU/Hr Model)

When Gas Quality Is Bad

burner will not stay lit

burner will produce flames and soot

 

 

 

Limit

Sail Switch

 

 

 

Switch

Thermostat

 

 

 

White

 

 

 

White

Red

Black

 

 

 

Junction

 

 

Green

 

 

Box

 

Time Delay

 

 

 

 

Brown

V.A.C.

Black

Black

Black

Relay

Green

 

Terminal Block

 

Yellow

 

 

 

 

115

 

 

 

 

 

 

 

 

Orange

White

White

 

 

 

 

Blue

 

 

Red

 

 

 

 

 

 

Brown

 

Transformer

Black

 

 

 

 

Brown

 

 

 

 

 

370V.A.C. Capacitor

White

5 MFD

Brown

Gas Valve

White

 

White

 

 

Brown

 

 

 

 

 

White

Brown

White

 

 

 

Black

 

 

Motor

 

 

Note:

 

 

Green

 

 

1

 

2

Ignition

3

Control

Board

4

5 (Open)

6

7

Black

Black Probe

White

White Glo-Bar

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact your installer, a qualified service person, or Williams Technical Help Line at 1-800-266-0993.

Figure 21 - Wiring Diagram (40,000 BTU/Hr Model)

201842

19

Image 19
Contents For Your Safety OWNER’S Operation and Installation ManualFor Your Safety What to do if YOU Smell GAS Safety Information Unpacking Product FeaturesSpecifications Local CodesLocating Furnace InstallationInstallation Items Check GAS TypeCreating Wall Opening and Mounting Furnace Installing ThermostatInstalling in Normal Frame Wall Installing in Masonry WallRouting Thermostat Cable Locating Thermostat on WallConnecting Furnace to Gas Supply at Front of Furnace Connecting to GAS SupplyMounting the Thermostat to Wall Removing Screws on Lower Flange 40,000 BTU/Hr Model Shown Connecting Furnace to Gas Supply at Rear of FurnaceExample Providing Gas Piping to FurnaceChecking GAS Connections Pressure Testing Gas Supply Piping SystemPerformance Check Pressure Testing Furnace Gas ConnectionsOperating Furnace For Your Safety Read Before LightingOperating Instructions Thermostat Control Operation Inspecting Burner FlameNormal Operating Sequence To Turn OFF GAS To FurnaceCleaning and Maintenance Observed Problem Possible Cause Remedy TroubleshootingIgnition Failures Observed Problem Possible Cause Wire and wire connections at probe Parts Wiring Diagrams ReplacementService Hints Technical ServiceCabinet Assembly 25,000 BTU/HR Model Illustrated Parts ListCabinet Assembly 40,000 BTU/HR Model Combustion Chamber Assembly 25,000 BTU/HR Model Combustion Chamber Assembly 40,000 BTU/HR Model Burner Assembly 25,000 BTU/HR Model Burner Assembly 40,000 BTU/HR Model Blower Assembly 25,000 BTU/HR Model Blower Assembly 40,000 BTU/HR Model Limited Warranty Williams GAS Wall Furnace Warranty Information

2503532, 4003532 specifications

The Williams 4003532,2503532 represents a significant advancement in modern technology, embodying a blend of innovative features and state-of-the-art components designed to enhance user experience across a variety of applications. This model is a prime example of Williams' commitment to quality and efficiency, making it a top choice for consumers seeking reliability and performance.

One of the standout features of the Williams 4003532,2503532 is its robust build quality. Engineered with precision, it utilizes high-grade materials that not only ensure durability but also contribute to its lightweight design. This combination makes the device easy to transport while maintaining its structural integrity, even in challenging environments.

In terms of technology, the Williams 4003532,2503532 is equipped with advanced processing capabilities that facilitate seamless operation. The integrated chipset provides rapid response times, which is crucial for applications requiring high-speed data processing and real-time analysis. This feature is particularly beneficial in fields such as telecommunications, where efficiency is paramount.

Furthermore, the device supports a wide array of connectivity options, ensuring compatibility with various peripherals and systems. This versatility allows users to integrate the Williams model into their existing setups without the need for extensive modifications. The inclusion of both wired and wireless connectivity options makes it adaptable for diverse usage contexts, whether in a professional setting or at home.

Another significant characteristic of the Williams 4003532,2503532 is its user-friendly interface. Designed with the end-user in mind, the interface facilitates easy navigation through features and settings, making it accessible even for those who may not be tech-savvy. This focus on usability enhances the overall experience, allowing users to maximize the potential of the device without a steep learning curve.

Additionally, energy efficiency is a core attribute of the Williams 4003532,2503532. The technology implemented in this model is aimed at minimizing power consumption while optimizing performance. This not only contributes to cost savings in the long run but also aligns with growing environmental concerns surrounding energy usage and sustainability.

In summary, the Williams 4003532,2503532 stands out due to its exceptional build quality, advanced technological specifications, versatile connectivity options, user-friendly interface, and energy efficiency. Together, these features make it an ideal choice for a wide range of users looking for a reliable and high-performing device that can meet their demanding needs. As technology continues to evolve, the Williams 4003532,2503532 sets a benchmark for what consumers can expect from modern devices.