Williams 2503532, 4003532 installation manual Ignition Failures

Page 16

THE COMFORT PRODUCTS PEOPLE

DIRECT-VENT NATURAL GAS HEATER

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

No heat (continued)

7.

Blower not operating

7.

A. Check power supply to furnace

 

 

 

 

B. Check electrical connections at furnace

 

 

 

 

C. With thermostat points closed, check for cir-

 

 

 

 

cuit completion at motor. If voltage is present,

 

 

 

 

replace motor. If no voltage is present at mo-

 

 

 

 

tor, check for:

 

 

 

 

• 24 volts on secondary coil or transformer. If

 

 

 

 

no voltage, replace transformer.

 

 

 

 

• If 24 volt transformer okay, check for circuit

 

 

 

 

completion across contacts on time delay

 

 

 

 

relay. Allow three to five seconds for con-

 

 

 

 

tact to close

 

 

 

 

• If circuit across contacts okay, check conti-

 

 

 

 

nuity of wiring in motor circuit

 

8.

Short cycling (motor goes on and off)

8.

A. Check thermostat. Contacts should remain

 

 

 

 

closed. If contacts are breaking:

• Check thermostat anticipator setting. It should be between .75 and 1.0

• If anticipator setting okay, check amp draw across thermostat. If amp draw exceeds .65, check amp draw across coil of valve and time delay relay. Note: On initial operation of glo bar, there is a momentary surge of approxi- mately 4.0 amps

• If amp draw is within limits, check for shorts in thermostat wiring

• If wiring is okay, replace thermostat

IGNITION FAILURES

WARNINGS:

Never connect unit or ignition circuit to 230 volts.

Never operate unit with glo bar touching burner or any other ground. Damage to ignition control will occur.

Be sure sensor probe never touches glo bar. This will dam- age ignition control.

If the ignition control is defec- tive, it must be replaced. It is not field-repairable.

The electronic system is made up of two parts: the ignition control and the glo bar. The ignition control is the brain of the elec- tronic system. It has several functions:

1.When the blower reaches full r.p.m., a 24-volt circuit is completed to the ig- nition control. (Check across yellow and orange wires.)

2.The red and blue wires at the ignition control are the 120-volt input for the glo-bar circuit. When the 24-volt cir- cuit is completed, the ignition control will complete the 120-volt circuit to the glo bar and it begins to glow. (Check this circuit across the two white wires at the ignition control.)

nition control to a neutral ground.) This circuit opens the valve, gas flows to the burner and is ignited by the heat from the glo bar. Note: Glo bar remains on.

4.When the burner flame is established, the sensing probe will sense the pres- ence of burner flame and open the glo- bar circuit. The glo bar will then stop glowing.

It is important to determine the type of problem being experienced. Then the proper checkout procedure can be made. The fol- lowing is a list of problems, how to identify in which area the problem is located, and how to correct it.

CAUTION: Do not attempt to repair the ignition control. This may alter it and cause it to oper- ate incorrectly.

3.After approximately 20 seconds, a 24- volt circuit is completed through the ig- nition control to the gas valve. (This cir- cuit is checked from brown wire at ig-

16

201842

Image 16
Contents For Your Safety OWNER’S Operation and Installation ManualFor Your Safety What to do if YOU Smell GAS Safety Information Product Features SpecificationsLocal Codes UnpackingInstallation Installation ItemsCheck GAS Type Locating FurnaceInstalling Thermostat Installing in Normal Frame WallInstalling in Masonry Wall Creating Wall Opening and Mounting FurnaceLocating Thermostat on Wall Routing Thermostat CableConnecting Furnace to Gas Supply at Front of Furnace Connecting to GAS SupplyMounting the Thermostat to Wall Connecting Furnace to Gas Supply at Rear of Furnace Removing Screws on Lower Flange 40,000 BTU/Hr Model ShownProviding Gas Piping to Furnace ExamplePressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Furnace Gas Connections Performance CheckOperating Furnace For Your Safety Read Before LightingOperating Instructions Inspecting Burner Flame Normal Operating SequenceTo Turn OFF GAS To Furnace Thermostat Control OperationCleaning and Maintenance Troubleshooting Observed Problem Possible Cause RemedyIgnition Failures Observed Problem Possible Cause Wire and wire connections at probe Wiring Diagrams Replacement Service HintsTechnical Service PartsIllustrated Parts List Cabinet Assembly 25,000 BTU/HR ModelCabinet Assembly 40,000 BTU/HR Model Combustion Chamber Assembly 25,000 BTU/HR Model Combustion Chamber Assembly 40,000 BTU/HR Model Burner Assembly 25,000 BTU/HR Model Burner Assembly 40,000 BTU/HR Model Blower Assembly 25,000 BTU/HR Model Blower Assembly 40,000 BTU/HR Model Warranty Information Limited Warranty Williams GAS Wall Furnace

2503532, 4003532 specifications

The Williams 4003532,2503532 represents a significant advancement in modern technology, embodying a blend of innovative features and state-of-the-art components designed to enhance user experience across a variety of applications. This model is a prime example of Williams' commitment to quality and efficiency, making it a top choice for consumers seeking reliability and performance.

One of the standout features of the Williams 4003532,2503532 is its robust build quality. Engineered with precision, it utilizes high-grade materials that not only ensure durability but also contribute to its lightweight design. This combination makes the device easy to transport while maintaining its structural integrity, even in challenging environments.

In terms of technology, the Williams 4003532,2503532 is equipped with advanced processing capabilities that facilitate seamless operation. The integrated chipset provides rapid response times, which is crucial for applications requiring high-speed data processing and real-time analysis. This feature is particularly beneficial in fields such as telecommunications, where efficiency is paramount.

Furthermore, the device supports a wide array of connectivity options, ensuring compatibility with various peripherals and systems. This versatility allows users to integrate the Williams model into their existing setups without the need for extensive modifications. The inclusion of both wired and wireless connectivity options makes it adaptable for diverse usage contexts, whether in a professional setting or at home.

Another significant characteristic of the Williams 4003532,2503532 is its user-friendly interface. Designed with the end-user in mind, the interface facilitates easy navigation through features and settings, making it accessible even for those who may not be tech-savvy. This focus on usability enhances the overall experience, allowing users to maximize the potential of the device without a steep learning curve.

Additionally, energy efficiency is a core attribute of the Williams 4003532,2503532. The technology implemented in this model is aimed at minimizing power consumption while optimizing performance. This not only contributes to cost savings in the long run but also aligns with growing environmental concerns surrounding energy usage and sustainability.

In summary, the Williams 4003532,2503532 stands out due to its exceptional build quality, advanced technological specifications, versatile connectivity options, user-friendly interface, and energy efficiency. Together, these features make it an ideal choice for a wide range of users looking for a reliable and high-performing device that can meet their demanding needs. As technology continues to evolve, the Williams 4003532,2503532 sets a benchmark for what consumers can expect from modern devices.