Louisville Tin and Stove W255F, W506F, W505F, W256F warranty Safety Rules, Naturalgas

Page 3

SAFETY RULES

CONTROLS

A)The wall furnace should be located near the center of the house for best heat distribution.

B)Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

C)Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.

D)Young children should be carefully supervised when they are in the same room as the appliance.

E)Do not place clothing or other flammable material on or near the appliance. Precautions should be taken so as not to place furniture, drapes, or other articles directly in front of grille or lower access door that would obstruct air openings as proper air flow is critical to proper operation of unit.

F)Any safety screen guard or casing front removed for servicing an appliance must be replaced prior to operating the appliance.

G)If the area where the appliance is to be installed contains carpeting, tile or combustible materials, other than wood flooring, the appliance shall be installed on a metal plate, a wood panel or other non- combustible materials. The use of ceramic or quarry tile is acceptable and will provide a surface that is easily cleaned. This material is to extend the full width and depth of the appliance.

CLEARANCES

As viewed from front of heater, the minimum clearance from cabinet to combustible construction: Side Wall – 1”; Floor – 2”; Ceiling – 11”.

In selecting a location for installation it is necessary to provide adequate accessibility clearances for servicing and proper operation. This appliance must not be connected to a chimney flue that serves to vent a solid-fuel burning (wood or coal) appliance, or a multi-vent system.

1” 11”

2”

All controls are preassembled at the factory.

The normal manifold pressure should be 3.5” w.c. on Natural Gas and 10” w.c. on L.P. Gas. The maximum inlet pressure in the gas supply pipe should never exceed 14” w.c. on L.P. Gas or 7.0” w.c. on Natural Gas.

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig.

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig.

The minimum inlet pressure in the gas supply pipe should be 5.0” w.c. on Natural Gas or 11” w.c. on L.P. Gas, “for purpose of input adjustment”.

The appliance is orificed at the factory for elevations up to 2,000 feet. If installed above 2,000 feet, the BTU input must be reduced 4% per 1,000 feet. See the following orifice chart for the proper orifice for a specific elevation. A blank orifice is shipped in the high altitude kit with each heater. This orifice(s) will have to be drilled to correct size by installer, gas supplier or qualified serviceman.

NATURALGAS

 

Model

0 to

2,000 -

4,000 -

6,000 -

8,000 –

 

No.

2,000’

4,000’

6,000’

8,000’

10,000’

 

W255F

43

44

45

47

48

 

W355F

36

38

40

41

43

 

ORDER KIT #49820 45-1 HIGH ALTITUDE KIT

 

 

W505F

43

44

45

47

48

 

ORDER KIT #49850 2287-2 HIGH ALTITUDE KIT

 

 

 

L.P. GAS

 

 

 

 

 

 

 

 

 

 

Model

0 to

2,000 -

4,000 -

6,000 -

8,000 –

 

No.

2,000’

4,000’

6,000’

8,000’

10,000’

 

W256F

1.45mm

54

54

55

55

 

W356F

52

52

52

53

54

 

ORDER KIT #49820 45-1 HIGH ALTITUDE KIT

 

 

W506F

1.45mm

54

54

55

55

ORDER KIT #49850 2287-2 HIGH ALTITUDE KIT

Page 3

Image 3
Contents What to do if YOU Smell GAS This Unit is not to be Installed in Mobile HomesNaturalgas GASIntroduction ContentsReadcarefullybefore Installingunit SpecificationsNaturalgas Safety RulesCombustion and Ventilation AIR ALL Combustion AIR from Outdoors Throughventilatedattic FigureaSquare Hole BTU Size = VentingGAS Supply FigureaROUGH-IN Instructions ROUGH-IN DimensionsVent Burner Shelf InstallationThermostat Wiring Instructions GravitywallfurnaceFor Installation Instructions WallPilot What to do if YOU Smell GASMaintenance Instructions Pilot Flame AdjustmentBurner Flame Adjustment Stainless Steel Burner Pilot AdjustmentStep Bbsk Installation InstructionsSide Views / Front Panel Control Switch Shield BracketScrew Gasvalvebbskcontrol Switch Black WireGascontrolknob Bbsk KIT Lighting InstructionsModel WFF81-COPTIONAL FAN KIT White Black FAN Switch White Motor Green Ground Wire WFF81-C Wiring SchematicHolefor Opening 7/8 Back From Each Register Stud PlasterInnerpanel Rear Register KITSymptom Possible Causes Corrective Action Trouble Shooting Chart for qualified serviceman Main BurnerTrouble Shooting Chart Automatic Pilot & Valve Do not Bypass the Blocked Flue SwitchPossible Causes Corrective Action Singlewallfurnace BURNERASSEMBLY/ Single Wall FurnaceBURNERASSEMBLY/ Dual Wall Furnace Gravity Wall Furnace List Prices - MarchW25F W35F W50F TWO RequiredTampering is Dangerous Your GAS Control and Pilot Light SystemLimited Warranty

W506F, W505F, W255F, W256F specifications

Louisville Tin and Stove, a well-respected name in the hearth products industry, has made significant strides in delivering high-quality wood and gas stoves. Among their impressive lineup, the models W256F, W505F, W506F, and W255F stand out for their exceptional features, advanced technologies, and distinctive characteristics.

The W256F model is renowned for its traditional design paired with modern efficiency. This stove is equipped with a large firebox that allows for longer burn times, ensuring a consistent heat output that effectively warms your living space. Its easy-to-use air control system provides users with optimal combustion, allowing you to adjust the flame intensity for a customized heating experience. The W256F also comes with a sleek glass door, enabling a beautiful view of the fire while maximizing heat retention.

Next in line, the W505F model showcases a more contemporary aesthetic. This stove features an innovative linings technology that promotes even heating and increases fuel efficiency. Its built-in catalytic combustor ensures that most of the smoke and particulate matter generated during combustion is burned off, making it an environmentally friendly choice. The W505F offers customizable trim options, allowing homeowners to match the stove seamlessly with their interior decor.

The W506F is another gem in this collection, notable for its impressive heating capacity. Designed for larger spaces, this model combines power with versatility. It features an advanced convection system that circulates warm air more effectively throughout the room. Additionally, the W506F incorporates a high-efficiency wood-burning design that offers reduced emissions and greater fuel economy, making it a sustainable option for eco-conscious consumers.

Finally, the W255F model caters to those who appreciate a compact yet powerful stove. Ideal for smaller homes or cabins, the W255F delivers robust heat output in a space-saving design. Its quick-response heating capabilities are enhanced by a reliable draft control system that ensures efficient fuel use. This stove also prioritizes safety, equipped with a heat shield to protect surrounding surfaces.

In summary, the Louisville Tin and Stove W256F, W505F, W506F, and W255F models lead the market with their distinctive features and innovative technologies. Together, they offer a range of options for consumers seeking efficiency, aesthetic appeal, and reliable performance. Whether you prefer a traditional classic, contemporary design, or a compact solution, these stoves are engineered to deliver warmth and comfort while upholding environmental standards.