Louisville Tin and Stove CF354C-R, CF654C-R Contents, Counterflow Wall Furnace Specifications

Page 2

CONTENTS

Contents……………………………………………........... 2

Lighting & Re-Lighting Instructions……………….. 10,11

Introduction…………………………………………. 2

Operation………………………………………….....….

12

Specifications………………………………………..

2

Terminal Block Wiring Diagram……………….....…… 13

Safety Rules…………………………………………

3

Manual Reset…………………………………....……..

13

Helpful Installation Information……………….........….

3

Maintenance Instructions…………………….………

13

Connecting the Vent……………………………....…..… 3,4

Wiring Diagram……………………………….....…….. 14,15

Combustion and Ventilation Air

5

Side & Rear Discharge Kits……………………...……16,17

Furnace Location………………………………….....….

6

Trouble Shooting Chart…………………………..….. 18,19

Rough-In Instructions…………………………..…..…. 6,7

Repair Parts (break down)………………………..….. 20-24

Installation……………………………………….......…..

8

Repair Parts List…………………………………....…. 21-25

Controls…………………………………………........…..

9

Warranty………………………………………….....….

27

Pilot Flame Adjustment…………………………......…..

9

 

 

INSTALLER MUST LEAVE THESE INSTRUCTIONS WITH THE CONSUMER, HAVE THEM COMPLETE, AND RETURN THE WARRANTY CARD.

INTRODUCTION

THIS IS A GAS-FIRED, GRAVITY VENTED WALL FURNACE THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE AGENCIES, THE GAS SUPPLIER, OR THE MANUFACTURER.

COUNTERFLOW WALL FURNACE SPECIFICATIONS

Your counterflow wall furnace is packed in a single carton that also includes thermostat, thermostat wire, and insulated staples. The thermostat, wire, and staples are packed in the burner compartment and are accessible by removing the burner access door. While the burner access door is open, check the rating plate to verify that the model number is correct and that the wall furnace is equipped for the type gas you intend to use.

 

 

 

 

Vent

 

 

 

 

 

Approx.

Model

Type

Type

BTU/HR.

Size

Gas

 

Blower

 

Shipping

Number Control

Gas

Input

(Oval)

Inlet

Finished Dimensions

Speed

Amps

CFM

Weight

 

 

MODELS WITH LOW-BTU STANDING PILOT

 

 

 

CF353C

24 Volt

Nat.

35,000

4”

½”

14-5/16”Wx10¼”Dx78-5/8”H

1

1.95

320

95

Lbs.

CF354C

24 Volt

L.P.

35,000

4”

½”

14-5/16”Wx10¼”Dx78-5/8”H

1

1.95

320

95

Lbs.

CF503C

24 Volt

Nat.

50,000

4”

½”

14-5/16”Wx10¼”Dx81-5/16”H

2

2.25

440

104 Lbs.

CF504C

24 Volt

L.P.

50,000

4”

½”

14-5/16”Wx10¼”Dx81-5/16”H

2

2.25

440

104 Lbs.

CF653C

24 Volt

Nat.

65,000

4”

½”

14-5/16”Wx10¼”Dx87-5/16”H

2

2.25

440

107 Lbs.

CF654C 24 Volt

L.P.

65,000

4”

½”

14-5/16”Wx10¼”Dx87-5/16”H

2

2.25

440

107 lbs.

 

 

 

 

 

 

 

 

 

 

MODELS WITH INTERMITTENT IGNITION

 

 

 

CF357C

24 Volt

Nat.

35,000

4”

½”

14-5/16”Wx10¼”Dx78-5/8” H

1

2.2

320

95

Lbs.

CF358C

24 Volt

L.P.

35,000

4”

½”

14-5/16”Wx10¼”Dx78-5/8”H

1

2.25

320

95 Lbs.

CF557C

24 Volt

Nat.

55,000

4”

½”

14-5/16”Wx10¼”Dx87-5/16”H

2

2.5

440

107 Lbs.

CF558C

24 Volt

L.P.

55,000

4”

½”

14-5/16”Wx10¼”Dx87-5/16”H

2

2.55

440

107 Lbs.

 

 

 

 

 

 

 

 

 

 

 

 

Page 2

Image 2
Contents This Unit is not to be Installed in Mobile Homes What to do if YOU Smell GASContents Counterflow Wall Furnace SpecificationsVenting Safety RulesRead Carefully Before Installing Unit Venting See List of Possible Causes and Corrections onOpenings Combustion and Ventilation AIRALL Combustion AIR from Adjacent Indoor Electrical ROUGH-IN Location and Special PrecautionsROUGH-IN Instructions GAS ROUGH-IN Installation When Installed Flush to Wall Installation / When RecessedNatural GAS Pilot AdjustmentPilot Flame Adjustment GASTo Turn OFF GAS to Appliance Standing Pilot For Your Safety Read Before LightingLighting Instructions What to do if YOU Smell GASMaximum High GAS Control Pressure Regulator Lever Maximum High Pressure Regulator GAS ControlProper Burner Flame OperationTerminal Block Wiring Diagram Auxiliary Limit SwitchMaintenance Instructions Standing Pilot Pictorial SchematicSchematic LadderModel NO. Amps IgnitionModule Model no AmpsRear Optional Accessory KitsROUGH-INS for Rear or Side Discharge SideModel Optional KitsSide Discharge on Casing NumberTrouble Shooting Chart for qualified serviceman Main Burner Trouble Shooting Chart Pilot and ValveSymptom Possible Causes Corrective Action Possible Causes Corrective ActionModels NAT. GAS Control AssemblyCounterflow Wall Furnace / Standing Pilot Requires TWO Volt System with LOW-B.T.U. Standing PilotCounterflow Wall Furnace / I.I.D. Pilot Models NAT. GAS L.P. GASVolt System with Intermittent Vent Trim KIT Enclosure KIT no 306SR-A Side Register Flush Rear Register W Boot FlushBoot RecessREV /97 March Your GAS Control and Pilot Light System Tampering is DangerousLouisville TIN and Stove Company Table a

CF354C-R, CF504R, CF654C-R specifications

The Louisville Tin and Stove CF654C-R, CF504R, and CF354C-R are three distinctive models designed to provide efficient heating solutions tailored for various spaces and specific needs. Known for their stylish design and practical functionality, these units stand as a testament to craftsmanship in modern heating technology.

One of the main features of these models is their robust construction. Crafted from durable materials, they are designed to withstand the rigors of daily use while providing reliable heat. The units showcase a combination of classic aesthetics and modern functionality, allowing them to fit seamlessly in any home environment, be it traditional or contemporary.

The CF654C-R model stands out with its higher heating capacity, making it ideal for larger rooms or spaces that require significant warmth. It uses innovative heat distribution technology that ensures even warmth throughout the area, eliminating cold spots and enhancing comfort. The integrated thermostat allows users to maintain optimal temperatures effortlessly, further emphasizing energy efficiency.

The CF504R model, while slightly smaller, does not compromise on performance. It offers a perfect solution for medium-sized spaces, featuring a user-friendly interface that makes it easy to adjust settings to suit individual preferences. Advanced combustion technology maximizes fuel efficiency, resulting in lower energy bills while still delivering the heating power you expect.

The CF354C-R is tailored for smaller areas, making it the perfect choice for cozy rooms or as an additional heat source in larger homes. Despite its compact size, it is engineered with a high thermal efficiency rating, ensuring that it uses minimal fuel to produce significant heat. Its minimalist design fits easily into smaller spaces without occupying much room, making it a versatile addition to any home.

Each model integrates modern safety features, including flame failure safety devices and protective screens, ensuring peace of mind for users. Additionally, all three models are designed to accommodate a variety of fuel types, allowing homeowners to choose based on convenience and availability.

In summary, the Louisville Tin and Stove CF654C-R, CF504R, and CF354C-R are versatile heating solutions that cater to different needs, with a focus on durability, efficiency, and user-friendly operation. With their unique features and technologies, they remain a popular choice for anyone looking to enhance their home’s heating system.