Bryant NAHA003WK.01 Thermostat Wiring For Single Stage Heating Two Stage Cooling

Page 8

Figure 6

 

ST 9120

 

 

 

 

 

 

 

 

Thermostat Wiring For

 

 

 

 

 

 

 

 

Single Stage Heating

 

 

 

 

 

 

 

 

And Two Stage Cooling

 

 

 

 

 

 

 

 

 

 

ELECTRONIC

 

 

 

 

 

 

 

 

 

 

FAN CONTROL

 

 

 

 

 

 

 

 

 

 

FURNACE #1

 

 

 

 

 

 

 

 

 

 

WALL

 

 

Connect Z1 To Z1

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect Z2 To Z2

 

 

 

 

 

G

Y2 Y1 W1 R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRONIC

 

 

 

 

 

 

 

 

 

 

FAN CONTROL

 

 

 

 

 

 

 

 

 

 

FURNACE #2

 

 

 

 

Y

 

 

4

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

A/C

 

 

 

 

 

 

 

 

 

 

 

 

 

ISOLATION

 

 

 

 

 

 

CONDENSERS

1

 

3

 

 

 

 

 

Y

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

Thermostat Wiring For

 

 

 

 

 

 

 

 

Two Stage Heating And

 

 

 

 

 

 

 

 

Single Stage Cooling

 

 

 

 

 

 

 

 

 

 

ELECTRONIC

 

 

 

 

 

 

 

 

 

 

FAN CONTROL

 

 

 

 

 

 

 

 

 

 

FURNACE #1

 

 

 

 

 

 

 

 

 

WALL

 

 

 

Connect Z1 To Z1

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

Connect Z2 To Z2

 

 

 

 

G

Y W2 W1 R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRONIC

 

 

 

 

 

 

 

 

 

 

FAN CONTROL

 

 

 

 

 

 

 

 

 

 

FURNACE #2

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

1

3

 

ISOLATION

A/C

C

Y

 

 

 

 

 

 

 

RELAY

CONDENSER

25--23--82

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

441 06 1003 02 (10/2001)

 

 

 

 

 

 

 

 

 

 

Image 8
Contents Twinning Kit NAHA003WK.01 Single Stage Thermostat Operation Twin Twining Leads 25--23--7825--23--79 Obtain necessary lengthSplice if Required,to Obtain necessary length Proper Connection of Twinning Leads for ST 25--23--80 Thermostat Wiring For Single Stage HeatingThermostat Wiring For Two Stage Heating Thermostat Wiring For Single Stage Heating Two Stage Cooling 25--23--81 Cooling Thermostat Wiring ForThermostat Wiring For Two Stage Heating Cooling Thermostat Wiring For Single Stage Heating Cooling

NAHA003WK.01 specifications

The Bryant NAHA003WK.01 is a cutting-edge air conditioning unit designed for both residential and light commercial applications. As a reliable brand in the HVAC industry, Bryant offers this model with a focus on energy efficiency, comfort, and advanced technology.

One of the standout features of the Bryant NAHA003WK.01 is its impressive SEER (Seasonal Energy Efficiency Ratio) rating, which ensures lower energy consumption and reduced utility bills. This model is engineered to operate efficiently, making it environmentally friendly while providing optimal cooling performance. The high efficiency is particularly beneficial for users looking to maintain a cool indoor environment without incurring high energy costs.

A key technology integrated into the Bryant NAHA003WK.01 is its variable-speed compressor. This advancement allows the unit to adjust its cooling output based on the current temperature demands, which means it can run at lower speeds for longer periods. This not only enhances energy savings, but also aids in maintaining consistent indoor temperatures, leading to improved overall comfort.

Moreover, the Bryant NAHA003WK.01 is equipped with a robust air filtration system designed to improve indoor air quality. With a filter that captures dust, allergens, and other particulates, this unit helps create a healthier living space. The ease of access to the filter also makes maintenance straightforward, allowing users to replace or clean the filter without hassle.

Durability is another characteristic of the Bryant NAHA003WK.01. Constructed with high-quality materials, the unit is built to withstand various weather conditions, ensuring longevity and reliable performance over time. Its compact design also allows for flexible installation options, making it suitable for different spaces without compromising on aesthetics.

In terms of controls, the Bryant NAHA003WK.01 features advanced smart technology compatibility. Users can easily integrate the unit with a smart thermostat or home automation systems, enabling convenient remote management. This allows individuals to adjust settings and optimize performance from their smartphones or tablets.

In summary, the Bryant NAHA003WK.01 air conditioning unit stands out for its energy efficiency, variable-speed compressor technology, superior air filtration system, durable construction, and smart controls. This makes it an ideal choice for those seeking a reliable and effective cooling solution that caters to modern comfort needs while being conscious of energy consumption.