Bryant CK5A, CK5B warranty Coil Static Pressure Drop In. WC, Indoor Coil Pistons, Factory-Installed

Page 6

COIL STATIC PRESSURE DROP (In. WC)

UNIT SIZE

BULB

 

 

AIR QUANTITY (CFM)

 

 

 

 

 

 

 

 

 

 

 

 

400

500

600

700

800

A018

 

 

 

 

 

 

 

WET

0.08

0.12

0.16

0.22

0.29

 

 

DRY

0.07

0.11

0.15

0.20

0.27

 

 

 

 

 

 

 

 

 

 

600

700

800

900

A024

 

 

 

 

 

 

 

WET

0.16

0.21

0.26

0.31

 

 

DRY

0.14

0.19

0.24

0.29

 

 

 

 

 

 

 

 

 

 

600

700

800

900

W024

 

 

 

 

 

 

 

WET

0.15

0.20

0.24

0.30

 

 

DRY

0.13

0.18

0.23

0.29

 

 

 

 

 

 

 

 

 

 

700

800

900

1000

1100

A030

 

 

 

 

 

 

 

WET

0.17

0.22

0.28

0.33

0.41

 

 

DRY

0.16

0.21

0.27

0.32

0.40

 

 

 

 

 

 

 

 

 

 

700

800

900

1000

1100

W030

 

 

 

 

 

 

 

WET

0.13

0.16

0.20

0.24

0.27

 

 

DRY

0.10

0.14

0.17

0.20

0.24

 

 

 

 

 

 

 

 

A036

 

900

1000

1100

1200

1300

 

 

 

 

 

 

 

WET

0.18

0.22

0.26

0.30

0.35

T036

 

DRY

0.15

0.18

0.22

0.26

0.30

 

 

900

1000

1100

1200

1300

W036

 

 

 

 

 

 

 

WET

0.15

0.18

0.21

0.25

0.28

 

 

DRY

0.12

0.14

0.16

0.19

0.23

 

 

 

 

 

 

 

 

 

 

800

900

1000

1100

N036

 

 

 

 

 

 

 

WET

0.24

0.29

0.36

0.44

 

 

DRY

0.23

0.28

0.34

0.43

 

 

 

 

 

 

 

 

A042

 

1000

1100

1200

1300

1400

 

 

 

 

 

 

 

WET

0.18

0.21

0.25

0.28

0.32

T042

 

DRY

0.14

0.16

0.19

0.23

0.24

 

 

1000

1100

1200

1300

1400

N042

 

 

 

 

 

 

 

WET

0.22

0.26

0.30

0.35

0.41

 

 

DRY

0.18

0.22

0.26

0.30

0.34

 

 

 

 

 

 

 

 

A048

 

1300

1400

1500

1600

 

 

 

 

 

 

 

WET

0.21

0.24

0.28

0.31

T048

 

DRY

0.19

0.22

0.25

0.28

 

 

1300

1400

1500

1600

1700

W048

 

 

 

 

 

 

 

WET

0.16

0.17

0.19

0.21

0.23

 

 

DRY

0.14

0.16

0.18

0.20

0.22

 

 

 

 

 

 

 

 

 

 

1200

1300

1400

1500

N048

 

 

 

 

 

 

 

WET

0.25

0.30

0.34

0.40

 

 

DRY

0.23

0.27

0.31

0.35

 

 

 

 

 

 

 

 

 

 

1600

1700

1800

N060

 

 

 

 

 

 

 

WET

0.27

0.30

0.33

 

 

DRY

0.25

0.28

0.31

 

 

 

 

 

 

 

 

A060

 

1600

1700

1800

1900

2000

2100

 

 

 

 

 

 

 

WET

0.19

0.21

0.23

0.26

0.29

0.33

T060

 

DRY

0.17

0.19

0.21

0.23

0.25

0.28

 

 

1600

1700

1800

1900

2000

2100

X060

 

 

 

 

 

 

 

WET

0.21

0.23

0.25

0.27

0.29

0.31

 

 

DRY

0.16

0.18

0.20

0.22

0.25

0.27

 

 

 

 

 

 

 

 

INDOOR COIL PISTONS

 

FACTORY-INSTALLED

UNIT

INDOOR PISTON SIZE

 

 

CK5A/CK5BA018

52

 

 

CK5A/CK5BA024, W024

59

 

 

CK5A/CK5BA030, W030

67

 

 

CK5A/CK5BA036, N036, T036, W036

70

 

 

CK5A/CK5BA042, N042, T042

78

 

 

CK5A/CK5BA048, N048, T048, W048

84

 

 

CK5A/CK5BA060, N060, T060, X060

90

 

 

—6—

Image 6
Contents Sizes A018 thru A060 Form No. PDS CK5A.18.1Model Number Nomenclature Dimensions Weight LBUnit N042 1400 Gross Cooling Capacities MBHW036 W048Entering AIR DRY Bulb Temperature F Gross Cooling Capacities MBHFactor Indoor Coil Pistons FACTORY-INSTALLEDCoil Static Pressure Drop In. WC Unit Size Bulb AIR Quantity CFMPage Unit Familiarization Maintenance Installation Overview Packaged Service Training

CK5A, CK5B specifications

Bryant CK5B and CK5A air conditioning units represent an advanced leap in both residential and light commercial HVAC technology. Engineered by Bryant, a leader in the heating and cooling industry, these models are known for their impressive energy efficiency and robust performance.

One of the standout features of the CK5B and CK5A units is their SEER (Seasonal Energy Efficiency Ratio) ratings. Both models achieve high SEER ratings, allowing homeowners and businesses to significantly lower energy consumption while still enjoying optimal cooling comfort. This emphasis on energy efficiency aligns with modern environmental standards, helping to reduce the overall carbon footprint.

These air conditioning units integrate advanced technology, including the use of environmentally friendly refrigerants. By utilizing R-410A refrigerant, Bryant ensures that these systems operate efficiently without contributing to ozone depletion, showcasing a commitment to sustainability in HVAC solutions.

In terms of construction, the CK5B and CK5A models are built with durability in mind. They feature a galvanized steel cabinet that is designed to withstand harsh weather conditions, ensuring longevity and reliability. The units are also equipped with high-quality components, including a noise-reducing compressor and a louvered coil guard that protects the condenser coil from debris and physical damage.

Comfort is further enhanced with the units' variable-speed technologies. This allows the system to adjust its speed depending on the cooling demand, resulting in more consistent temperatures and a quieter operation. This flexibility also improves humidity control, ensuring that indoor environments remain comfortable throughout the changing seasons.

For ease of maintenance, both models come with built-in diagnostic capabilities. This feature helps technicians quickly identify issues, minimizing downtime and repair costs. The accessibility of components further simplifies service, making regular maintenance a less daunting task.

Additionally, Bryant offers comprehensive warranties on both the CK5B and CK5A units, providing peace of mind for customers. This commitment to quality assurance reinforces the brand's reputation in the industry.

In summary, the Bryant CK5B and CK5A air conditioning units combine energy efficiency, advanced technology, and durable construction to deliver exceptional cooling solutions. Their innovative features make them suitable for various applications, catering to the demands of today’s environmentally conscious consumers. Regardless of the setting, these models stand out as reliable options for efficient climate control.