Bryant 362AAN instruction manual This symbol → indicates a change since the last issue Index

Page 1

installation, start-up,

 

362AAN

and operating instructions

 

Series B

LOW-BOY

 

 

 

OIL-FIRED FURNACE

 

 

 

 

 

Cancels: II 362A-75-1

II 362A-105-1

 

 

8-96

NOTE: Read the entire instruction manual before starting the installation.

This symbol indicates a change since the last issue.

Index

Page

SAFETY CONSIDERATIONS

1-2

Minimum Clearance to Combustibles

2

INTRODUCTION

2

LOCATION

2-3

Air for Combustion and Ventilation

2-3

Duct Work Recommendations

3

VENTING INSTRUCTIONS

4

Pre-Installation Vent System Inspection

4

Masonry Chimney

4

Factory-Built Chimneys

4

Horizontal Venting

4

OIL BURNER

4

OIL CONNECTIONS

4

BAROMETRIC DRAFT CONTROL

4

ELECTRICAL

5

FILTERS

5

OPERATIONAL CHECKOUT

5-6

Start-Up

5

Recommended Installation Practices and

 

Combustion Check

5-6

Fan Adjustment Check

6

Limit Control Check

6

For Year-Round Air Conditioning

6

Heating

6

Cooling

6

Constant Blower Switch

6

MAINTENANCE

6-11

General

6

Oil Burner

6-7

Heat Exchanger and Flue Pipe

7-8

Blower Oiling and Removal

8

Keeping Filters Clean

8

Airflow Data

8

Dimensional Drawing

9

Barometric Damper Locations

10

Wiring Diagram

11

USER'S INFORMATION

12

Here's How Your Heating System Works

12

Preparing Your Furnace For Operation

12

Lighting Your Furnace

12

Turning Off Your Furnace

12

SAFETY CONSIDERATIONS

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQ- UIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

DO NOT ATTEMPT TO START THE BURNER WHEN EXCESS OIL HAS ACCUMULATED, WHEN THE FURNACE IS FULL OF VAPOR, OR WHEN THE COMBUSTION CHAMBER IS VERY HOT.

WARNING: For use with grade 2 Fuel Oil maximum.

Do not use Gasoline, Crankcase Oil, or any Oil contain- ing Gasoline! Failure to follow this warning could lead to sooting, fire, explosion, and/or severe bodily harm.

CAUTION: Never burn garbage or paper in the heating system and never leave rags, paper, or any flammable

items around the unit.

CAUTION: These instructions are intended to be used by qualified personnel who have been trained in installing this type of furnace. Installation of this furnace by an unqualified person may lead to equipment damage and/or a hazardous condition which may lead to bodily harm.

All local and national code requirements governing installation of oil burning equipment, wiring, and flue connections must be followed. Some of the codes (issued by the Canadian Standards Association, the National Fire Protection Agency, and/or the American National Standards Institute) that may be applicable are:

ANSI/NFPA 31 INSTALLATION OF OIL BURNING EQUIPMENT

ANSI/NFPA 211 CHIMNEYS, FIREPLACES, VENTS, AND SOLID FUEL BURNING APPLIANCES

ANSI/NFPA 90B WARM AIR HEATING AND AIR CONDITIONING SYSTEMS

ANSI/NFPA 70 NATIONAL ELECTRICAL CODE

CSA B139 INSTALLATION CODE FOR

OIL BURNING EQUIPMENT

CSA C22.1 CANADIAN ELECTRICAL CODE

Ð1Ð

Image 1
Contents Recommended Installation Practices This symbol → indicates a change since the last issue IndexSafety Considerations Introduction Ðminimum Clearances to Combustible MaterialsLocation AIR for Combustion and VentilationLockouts on start-up Ð3ÐII. Duct Work Recommendations Venting Instructions PRE-INSTALLATION Vent System InspectionII. Masonry Chimney Ðminimum Certified Furnace Pipe SizeElectrical II. Recommended Installation Practices and Combustion CheckFilters Operational CheckoutVIII. Constant Blower Switch → ÐBURNER, NOZZLE, and Pump Pressure ChartMaintenance III. FAN Adjustment CheckÐ7Ð → III. Heat Exchanger and Flue PipeIV. Blower Oiling and Removal Keeping Filters Clean→ Ðairflow Data CFM Ð8ÐÐ9Ð DimensionsÐ10Ð BAD LocationsFactory SET Heating Speed Ð11ÐIII. Lighting Your Furnace Users Information Heres HOW Your Heating System WorksII. Preparing Your Furnace for Operation IV. Turning OFF Your Furnace

362AAN specifications

The Bryant 362AAN is an exemplary air conditioning unit renowned for its durability, efficiency, and advanced technology. Designed to cater to both residential and light commercial applications, the 362AAN stands out as a highly reliable solution for cooling needs.

One of the main features of the Bryant 362AAN is its high-efficiency performance. With SEER ratings reaching as high as 16, this unit can significantly reduce energy costs while providing optimal cooling. The 362AAN employs a two-stage cooling system that enhances comfort by maintaining a more consistent indoor temperature. This feature not only ensures a pleasant environment but also helps in saving energy by adjusting the cooling output according to the indoor conditions.

The Bryant 362AAN is built using high-quality materials and components, ensuring reliability and longevity. Its all-aluminum coil enhances corrosion resistance, making it suitable for various climates. This durability extends the unit's lifespan and reduces the need for frequent repairs or replacements, providing homeowners with peace of mind.

A standout technology in the Bryant 362AAN is the EcoNet Smart Thermostat compatibility, which allows users to monitor and control their cooling system remotely. This smart technology provides real-time data, enabling users to optimize energy consumption and receive alerts for maintenance needs. The integration of smart technology also allows for potential energy savings, as users can customize their cooling schedules based on their lifestyle.

Noise reduction is another key characteristic of the Bryant 362AAN. Designed with advanced sound technology, this unit operates at quieter levels, ensuring minimal disruption to indoor activities. This is particularly beneficial in residential areas where noise can be a concern.

In terms of installation versatility, the Bryant 362AAN can be easily integrated into various home setups. Its compact design and flexible installation options ensure that it can fit in tight spaces without compromising performance.

Overall, the Bryant 362AAN air conditioning unit combines efficiency, technology, and reliability to provide an outstanding cooling solution. With its range of features and commitment to sustainability, it remains a popular choice among homeowners and businesses looking to enhance their indoor comfort while minimizing energy consumption.