American Standard Noncondensing Gas Furnaces manual Required Filters Downflow

Page 17

FACTORY SUPPLIED UPFLOW FURNACE

RETURN AIR FILTERS

UPFLOW FURNACE RETURN AIR FILTERS

CABINET

QTY*

CABINET

CABINET

WIDTH

BOTTOM FILTER

SIDE FILTER

 

 

 

 

 

14-1/2"

1

14" X 25" X 1"

17-1/2" X 25" X 1"

 

 

 

 

17-1/2"

1

17" X 25" X 1"

17-1/2" X 25" X 1"

 

 

 

 

21"

1

20" X 25" X 1"

17-1/2" X 25" X 1"

 

 

 

 

24-1/2"

1

24" X 25" X 1"

17-1/2" X 25" X 1"

 

 

 

 

*NOTE - On 5 or 6 ton airflow models, if the airflow requirement exceeds 1800 CFM, these models will require filters on both sides; OR 1 side and the bottom; OR just the bottom.

WARNING: Disconnect power to the

unit before removing the blower door. Failure to follow this warning could result in property damage, personal injury or death.

Downflow Furnace Filters

Downflow/Horizontal furnaces use 2 standard size perma- nent type air filters which may be located remote to the furnace or in the return air duct. Check with your dealer for the location of your filters.

A downflow/horizontal furnace vertical return air filter application, as shown, features two 14" x 20" x 1" filter in the 14-1/2" wide furnace cabinets; or two 16" x 20" x 1" filter in the 17-1/2", 21", and 24-1/2" wide furnace cabinets.

DOWNFLOW FILTER

A downflow/horizontal furnace with horizontal return air filter application, as shown, features two 14" x 20" x 1" filter in the 14-1/2" wide furnace cabinets; or two 16" x 20" x 1" filter in the 17-1/2", 21", and 24-1/2" wide furnace cabinets.

DOWNFLOW/HORIZONTAL FILTER

DOWNFLOW FILTER TABLE

REQUIRED FILTERS - DOWNFLOW

CABINET WIDTH

FILTER QUANTITY & SIZE

 

 

 

14-1/2"

2 - 14" X 20" X

1"

 

 

 

17-1/2"

2 - 16" X 20" X

1"

 

 

 

21"

2 - 16" X 20" X

1"

 

 

 

24-1/2"

2 - 16" X 20" X

1"

 

 

 

Pub. No. 32-5034-02

Page 5

Image 17
Contents User’s Information Guide Carbon Monoxide Poisoning Hazard Fire or Explosion HazardClean filter saves money Filter maintenance reduces energy useHow to remove your filter Replacing your filterUpflow only Chamfer END Filter Goes Into Filter Rack FirstUpflow / Horizontal Furnace Filters UPFLOW/HORIZONTAL with Filter KITDOWNFLOW/HORIZONTAL Filter Downflow Filter Table Downflow Furnace FiltersDownflow Filter Keep your furnace looking like new for years Problem solverNever stop the cooling system by shutting off the main power Maintenance informationAir for combustion and ventilation For your safetyTo light furnace High Efficiency Induced Draft Gas Furnace Limited WarrantyFirst AID Measures Precautionary MeasuresAmerican Standard Inc Troup Highway Tyler, TX User’s Information Guide Fire or Explosion Hazard Filter maintenance reduces energy use Chamfer END Filter Goes Into Filter Rack First Required Filters Downflow Problem solver Maintenance information Nace To light furnace Limited Warranty Precautionary Measures American Standard Inc Troup Highway Tyler, TX