American Standard Noncondensing Gas Furnaces manual Filter maintenance reduces energy use

Page 3

Filter maintenance reduces energy use.

WARNING: Disconnect power to the

unit before removing the blower door. Failure to follow this warning could result in property damage,

personal injury or death.

A clean filter saves money.

When the furnace circulates and filters the air in your home, dust and dirt particles build up on the filter. Excessive accumulation can block the airflow, forcing the unit to work harder to maintain desired tempera- tures.

And the harder your unit has to work, the more energy it uses. So you pay more any time your system is run- ning with a dirty filter.

CAUTION: Never operate your unit for either heating or cooling with filters removed.

Help ensure top efficiency by cleaning the filter once a month. If you have an upflow furnace, you can wash or

change the filter once a month. Clean it twice a month during seasons when the unit runs more often.

Your furnace came from the factory with a cleanable filter. You can clean the filter with a vacuum, OR you can wash it with a household detergent. Good quality, high velocity filters may be used for replacements in upflow furnaces.

With the new patented filter rack on the upflow models, all cleaning or replacing of filters is quick and easy. Clean filters guarantee optimum performance of your system.

Replacing your filter.

When replacing your furnace filters, use a high velocity type filter. On upflow furnaces, standard size 1" thick high velocity filters will fit into the patented filter rack which will automatically adjust in width to fit. Filters are available from your dealer.

How to remove your filter.

WARNING: Disconnect power to the

unit before removing the blower door. Failure to follow this warning could result in property damage, personal injury or death.

The upflow furnace blower door has a hinge at the bottom which allows the door to tilt forward for filter servicing or replacement without the door being re- moved. The furnace filter in the bottom or side configu- ration can be removed by simply turning the two latches on the blower door 1/4 turn and tilting the door forward.

Blower Door Hinge and Bottom Filter Rack Installation

The blower door may be removed if necessary by tilting the door outward 2 to 3 inches, then pulling up. The door will slide out of the hinge for removal. For replacement, simply insert the blower door bottom into the space between the furnace base front and the hinge, then tilt inward and latch.

Typical Upflow Right Side Return Filter Installation

Pub. No. 32-5034-02

Page 3

Image 3
Contents User’s Information Guide Carbon Monoxide Poisoning Hazard Fire or Explosion HazardReplacing your filter Filter maintenance reduces energy useClean filter saves money How to remove your filterUPFLOW/HORIZONTAL with Filter KIT Chamfer END Filter Goes Into Filter Rack FirstUpflow only Upflow / Horizontal Furnace FiltersDownflow Furnace Filters Downflow FilterDOWNFLOW/HORIZONTAL Filter Downflow Filter Table Keep your furnace looking like new for years Problem solverNever stop the cooling system by shutting off the main power Maintenance informationAir for combustion and ventilation For your safetyTo light furnace High Efficiency Induced Draft Gas Furnace Limited WarrantyFirst AID Measures Precautionary MeasuresAmerican Standard Inc Troup Highway Tyler, TX User’s Information Guide Fire or Explosion Hazard Filter maintenance reduces energy use Chamfer END Filter Goes Into Filter Rack First Required Filters Downflow Problem solver Maintenance information Nace To light furnace Limited Warranty Precautionary Measures American Standard Inc Troup Highway Tyler, TX