American Standard Noncondensing Gas Furnaces manual Maintenance information

Page 19

Maintenance information.

Never stop the cooling system by shutting off the main power.

If the main power to your air conditioner is ever discon- nected for more than three hours, turn off the thermostat. Then wait for at least three more hours after the power has been restored before turning the thermostat back on. Failure to follow this procedure could result in damage to your air conditioning system.

1.GENERAL INSPECTION - Examine the furnace instal- lation for the following items:

a.All flue product carrying areas external to the fur- nace (i.e. chimney, vent connector) are clear and free of obstruction.

b.The vent connector is in place, slopes upward and is physically sound without holes or excessive corrosion.

c.The return air duct connection(s) is physically sound, is sealed to the furnace and terminates outside the space containing the furnace.

d.The physical support of the furnace should be sound without sagging, cracks, gaps, etc., around the base so as to provide a seal between the support and the base.

e.There are no obvious signs of deterioration of the furnace.

WARNING:

Do not touch igniter. It is extremely hot. Failure to follow this warning could result in severe burns.

2.BLOWERS - The blower size and speed determine the air volume delivered by the furnace. The blower motor bearings are factory lubricated and under normal operat- ing conditions usually do not require servicing. Annual cleaning of the blower wheel and housing is recommended for maximum air output, and this must be performed only by a qualified servicer or service agency.

3.IGNITER - This unit has a special hot surface direct ignition device that automatically lights the burners. Please note that it is very fragile and should be handled with care.

CAUTION: Do not touch igniter. It is extremely hot.

4.BURNER - Gas burners do not normally require sched- uled servicing, however, accumulation of foreign material may cause a yellowing flame or delayed ignition. Either condition indicates that a service call is required. For best operation, burners must be cleaned annually using brushes and vacuum cleaner.

Turn off gas and electric power supply. To clean burners, remove top burner bracket and lift burner from orifice.

NOTE: Be careful not to break igniter when remov- ing burners. Clean burners with brush and/or vacuum cleaner. Reassemble parts by reversal of the above proce- dure.

Pub. No. 32-5034-02

NOTE: On LP (propane) units, some light yellow tipping of the outer mantle is normal. Inner mantle should be bright blue.

Natural gas units should not have any yellow tipped flames. This condition indicates that a service call is required. For best operation, burners must be cleaned annually using brushes and vacuum cleaner.

NOTE: On LP (propane) units, due to variations in BTU content and altitude, servicing may be required at shorter intervals.

5.HEAT EXCHANGER / FLUE PIPE - These items must be inspected for signs of corrosion, and/or deterioration at the beginning of each heating season by a qualified service technician and cleaned annually for best operation.

6.CIRCUIT PROTECTION - If blower or gas valve fail to operate, the cause could be the circuit breaker or a loose or blown fuse. Replace fuse or reset circuit breaker.

7.OPERATION - Your warm air furnace should not be operated in a corrosive atmosphere. Paint solvents, clean- ing chemicals, spray propellants, and bleaches should not be used in the vicinity of the furnace during normal operation.

8.COOLING COIL CONDENSATE DRAIN - If you have a cooling coil installed with your furnace, condensate drains should be checked and cleaned periodically to as- sure that condensate can drain freely from coil to drain. If condensate cannot drain freely water damage could occur.

9.AIR CIRCULATION - To ensure increased comfort, blower on this unit may be operated continuously for both heating and cooling. This will result in constantly filtered air and aid in maintaining more even temperatures by avoiding temperature stratification throughout the condi- tioned area. To accomplish constant air circulation, set your thermostat fan switch to "ON".

Page 7

Image 19
Contents User’s Information Guide Carbon Monoxide Poisoning Hazard Fire or Explosion HazardReplacing your filter Filter maintenance reduces energy useClean filter saves money How to remove your filterUPFLOW/HORIZONTAL with Filter KIT Chamfer END Filter Goes Into Filter Rack FirstUpflow only Upflow / Horizontal Furnace FiltersDownflow Filter Downflow Furnace FiltersDOWNFLOW/HORIZONTAL Filter Downflow Filter Table Keep your furnace looking like new for years Problem solverNever stop the cooling system by shutting off the main power Maintenance informationAir for combustion and ventilation For your safetyTo light furnace High Efficiency Induced Draft Gas Furnace Limited WarrantyFirst AID Measures Precautionary MeasuresAmerican Standard Inc Troup Highway Tyler, TX User’s Information Guide Fire or Explosion Hazard Filter maintenance reduces energy use Chamfer END Filter Goes Into Filter Rack First Required Filters Downflow Problem solver Maintenance information Nace To light furnace Limited Warranty Precautionary Measures American Standard Inc Troup Highway Tyler, TX