Carrier 58ZAV ÐElectrical Data, Accessories, ÐVenting, Unit Amps Wire Gage Length FT³ Phase AMPS²

Page 11

Table 6ÐElectrical Data

 

VOLTSÐ

OPERATING VOLTAGE RANGE

MAXIMUM

MINIMUM

MAXIMUM WIRE

MAXIMUM

UNIT SIZE

HERTZÐ

 

 

FUSE OR CKT BKR

Maximum*

Minimum*

UNIT AMPS

WIRE GAGE

LENGTH FT³

 

PHASE

AMPS²

 

 

 

 

050-08

115Ð60Ð1

127

104

6.6

14

42

15

050-12

115Ð60Ð1

127

104

8.1

14

34

15

070-08

115Ð60Ð1

127

104

6.7

14

42

15

070-12

115Ð60Ð1

127

104

8.4

14

33

15

096-12

115Ð60Ð1

127

104

9.2

14

30

15

096-16

115Ð60Ð1

127

104

10.2

14

28

15

115-16

115Ð60Ð1

127

104

10.1

14

28

15

115-20

115Ð60Ð1

127

104

13.3

12

33

20

115-22

115Ð60Ð1

127

104

15.2

12

29

20

135-20

115Ð60Ð1

127

104

14.3

12

31

20

 

 

 

 

 

 

 

 

*Permissible limits of the voltage range at which the unit will operate satisfactorily. ² Time-delay type is recommended.

³ Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.

GAS

SUPPLY

MANUAL

SHUTOFF VALVE (REQUIRED)

SEDIMENT

TRAP

UNION

A89414

Fig. 13ÐTypical Gas Pipe Arrangement

Canadian installations, all electrical connections must be made in accordance with Canadian Electrical Code CSA C22.1, or authori- ties having jurisdiction.

NOTE: Proper polarity must be maintained for 115-v wiring. If polarity is incorrect, control status code indicator light will flash rapidly and furnace will not operate.

The cabinet MUST have an uninterrupted or unbroken ground according to NEC ANSI/NFPA 70-1999 and Canadian Elec- trical Code CSA C22.1 or local codes to minimize personal injury if an electrical fault should occur. This may consist of electrical wire or conduit approved for electrical ground when installed in accordance with existing electrical codes. Do not use gas piping as an electrical ground. Failure to follow this warning could result in electrical shock, fire, or death.

24-V WIRING

Make field 24-v connections at the 24-v terminal strip. (See Fig. 14.) Connect terminal Y as shown in Fig. 15 for proper operation in cooling mode. Use AWG No. 18 color-coded wire only.

The 24-v circuit contains an automotive-type, 3-amp fuse located on the main control board. Any direct shorts during installation, service, or maintenance could cause this fuse to blow. If fuse replacement is required, use ONLY a 3-amp fuse of identical size.

ACCESSORIES

1.Electronic Air Cleaner (EAC)

Two spring clamp terminals (for 12 gage maximum, solid or stranded wire), marked EAC-1 and EAC-2, are provided for EAC connection. (See Fig. 14.) These terminals are energized with 115v (1.5-amp maximum) during blower motor opera- tion. To connect EAC power leads to furnace control board, strip approximately 1/8 in. of insulation from wire. Open terminal by depressing switch arm with a screwdriver or finger, and insert wire as shown in Fig. 16.

2.Humidifier (HUM)

Screw terminals (HUM and COM-24V) are provided for 24-v humidifier connection. The terminals are energized with 24v (0.5-amp maximum) after inducer motor prepurge period.

Do not connect furnace control HUM terminal to HUM (humidifier) terminal on Thermidistat™, Zone Controller, or similar device. See Thermidistat, Zone Controller, thermostat, or controller manufacturer's instructions for proper connec- tion. A failure to follow this warning could result in fire.

NOTE: A field-supplied, 115-v controlled relay connected to EAC terminals may be added if humidifier operation is desired during blower operation.

Step 11ÐVenting

Refer to the national or local installation code such as NFGC in the United States, or the NSCNGPIC in Canada for proper vent sizing and installation requirements. Use the enclosed Installation In- structions (Single-Stage Vent Tables for Category I Fan-Assisted Furnaces) for a quick, easy reference.

After fully assembling the vent connector to the furnace flue collar, securely fasten the vent connector to the collar with two field- supplied, corrosion-resistant, sheet metal screws located 180° apart and midway up the collar.

The horizontal portion of the venting system shall maintain a minimum of 1/4-in. upward slope per linear ft and it shall be rigidly supported every 5 ft or less with hangers or straps to ensure that there will be no movement after installation.

11

Image 11
Contents Safety Considerations Electrostatic Discharge ESD PrecautionsUnit Size Vent Conn SHIP. WT LB → ÐDimensional Drawing ÐDimensionsElectrostatic Discharge ESD Precautions Procedure Introduction ÐClearances to CombustiblesÐAir For Combustion and Ventilation ÐLocationGeneral Hazardous LocationsÐDuctwork acoustical treatment Confined SpaceAIR Ducts ÐGeneral RequirementsHorizontal Furnaces → ÐMinimum Free Area Of Combustion Air OpeningÐSupply Air Connections Downflow FurnacesFurnace Plenum Opening Floor Opening Casing ÐDownflow InstallationÐHorizontal Attic Installation Construct a Working PlatformÐFurnace, Plenum, and Subbase Installed ÐGas Piping Install FurnaceÐHorizontal Crawlspace Installation ÐFilter ArrangementFurnace Casing Filter Size Width Quantity WiringÐMaximum Capacity of Gas Pipe ÐElectrical ConnectionsÐVenting AccessoriesUnit Amps Wire Gage Length FT³ Phase AMPS² ÐElectrical DataÐFurnace Control Sequence of Operation ÐStart-up, Adjustment, and Safety CheckÐFurnace Wiring Diagram Never Assume Orifice SIZE. Always Check and Verify START-UP ProceduresAdjustments Altitude BTU/CU FT600 625 Only 8001 650 675 700 725 9000 750 775 650 675 Only 700 6001 725 750 800 775 7000 825 850 875625 650 Only 675 7001 725 775 750 8000 825 850 700 10,000 725 750 ÐAltitude Derate Multiplier for U.S.AExample Only 9001→ ÐSpeed Selector ÐGas Rate Cu Ft/HrChecklist Check Safety Controls

58ZAV specifications

The Carrier 58ZAV is a high-efficiency gas furnace that exemplifies Carrier's commitment to innovation and performance in residential heating solutions. Designed to provide optimal comfort, the 58ZAV boasts a range of features that cater to the needs of homeowners seeking reliable and energy-efficient heating systems.

One of the standout characteristics of the Carrier 58ZAV is its impressive Annual Fuel Utilization Efficiency (AFUE) rating, which often exceeds 95%. This high AFUE ratio means that the furnace converts a significant portion of its fuel into heat, ensuring minimal energy waste and lower utility bills. This efficiency aligns with modern energy standards and reflects Carrier's dedication to environmentally conscious engineering.

The 58ZAV employs a two-stage heating process, which allows for better temperature control and more consistent comfort levels throughout the home. The furnace operates on low capacity for most of the heating cycle, ensuring that it does not overheat the living spaces. When a quick boost of heat is needed, it can switch to high capacity, providing the necessary warmth efficiently.

Additionally, this gas furnace features a variable-speed blower motor. This motor adapts its speed according to the heating demand, delivering more even airflow and maintaining consistent humidity levels within the home. This adaptability not only enhances comfort but also contributes to a quieter operation, minimizing disruptive noise levels typically associated with traditional furnaces.

Incorporating advanced technology, the Carrier 58ZAV is compatible with smart thermostats and can be integrated into a home automation system. This feature allows homeowners to monitor and control their heating system remotely, optimizing energy usage and comfort from anywhere.

The furnace is designed with durability in mind, featuring a corrosion-resistant heat exchanger and other robust components that ensure long-lasting performance. Moreover, Carrier offers a range of warranties, providing peace of mind to homeowners investing in this heating solution.

Overall, the Carrier 58ZAV is a top-of-the-line gas furnace that combines efficiency, advanced technology, and comfort. With its high AFUE rating, two-stage heating process, variable-speed blower motor, and compatibility with smart home systems, it represents a modern heating solution that meets the demands of today's environmentally aware consumers. Whether for new installations or replacements, the 58ZAV stands out as a reliable choice for residential heating needs.