Superior BRI-36/42-2, BC-36/42-2 Maintenance Guidelines, Before Each Use, Twice a Year CHECK-UP

Page 6

6

MAINTENANCE GUIDELINES

Your fireplace is designed to operate trouble- free with minimum maintenance. However, like any fine appliance, it deserves and requires some housekeeping attention.

Your fireplace will perform better – and cer- tainly look more attractive to family and friends

if it is cleaned before each use. Before the first seasonal use in Autumn and after the last fire in Spring, it is important to inspect the fireplace system carefully. We recommend at least two complete fireplace inspections a year.

Before Each Use

1.Clean the firebox of excessive ashes. Some owners prefer to leave a small layer to insulate the cold refractory below the grate which helps fire starting.

This fireplace has a factory supplied grate at- tached, it is permissible to remove the grate for cleaning; however, the grate must be re-at- tached to the fireplace before the next burn.

2.Keep the fireplace screens clean so combus- tion air flows freely.

3.Spot check the brick-like refractory for small cracks. Heat from the fire expands it slightly. When it cools, it contracts.

TWICE A YEAR CHECK-UP

Normally, twice a year, you should inspect your fireplace following this list:

1.Inspect the opening in your chimney top and remove any debris that could clog it. The cap is usually held in place by four (4) screws, which remove easily for checking or cleaning the full length of the flue from above. Remove the chimney top while wearing gloves to guard against any sharp metal edges.

2.Inspect the entire flue from the top down for obstructions such as birds nests, leaves, etc. This may be done by using a flexible handled chimney cleaning brush. If the chimney con- tains offset/return elbows; a soft brush cleaning from the top down to any elbow and then from the firebox up to the offset/return section is the proper method. The beam from a powerful flashlight will help in this inspection.

3.Look up from inside the fireplace (damper open) to see any obstructions in the lower flue area. If present, shut the damper and glass doors (if installed) to seal the firebox and contain any soot that might fall.

If your do not have glass doors installed, a damp sheet covering the fireplace opening and sealed with masking tape will do. Then clean the flue from the top down (if an offset system, clean per Step 2) using a proper size chimney brush with flexible pole sections. Don’t open the doors or remove the sheet until all soot has settled. Vacuum, don’t sweep.

4.Check the metal flashing and seals around your chimney. Seal any cracks or loose nail- head openings to prevent roof leaks.

5.Clean the firebox thoroughly by using a soft brush or equivalent.

WARNING: CONTINUED OVERFIRING CAN PERMANENTLY DAMAGE YOUR FIREPLACE SYSTEM. SOME EXAMPLES OF OVERFIRING ARE:

BURNING QUANTITIES OF SCRAP LUMBER, PINE BRANCHES, PAPER OR CARDBOARD BOXES WHICH EXCEED THE VOLUME OF THE NORMAL LOG FIRE.

BURNING TRASH, CHEMICALS OR CHEMICALLY TREATED COMBUS- TIBLES.

CREOSOTE FORMATION AND REMOVAL

When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creo- sote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lin- ing. When ignited, this creosote makes an extremely hot fire.

The chimney should be inspected at least twice yearly during the heating season to determine if a creosote build-up has occurred.

If creosote has accumulated, it should be re- moved to reduce the risk of a chimney fire.

If creosote build-up is found, do not use chemi- cal chimney cleaners that are poured on a hot fire. The chemical cleaners can be dangerous and generally only work on the flue section nearest the fire, leaving the rest of the flue unaffected. It is best to take the time to clean the flue as previously described or have the chim- ney professionally cleaned by a qualified chimney sweep.

TROUBLESHOOTING

No Smoking Allowed

Your new fireplace is designed not to smoke if properly installed and operated per our instruc- tions. If you do experience a problem, here are several things to check:

1.Remember – always check to ensure your flue damper is in the open position before lighting a fire!

2.When lighting your fire, a little smoke may escape into the room – more likely if the chim- ney is cold. To correct this, hold a lighted newspaper up inside the firebox near the open flue damper. This will turn around any down- draft and clear the flue of cold air. As your log fire burns below, the updraft will improve as the chimney heats up.

3.Is your fire too far forward? Move it toward the back with your poker. Keep the fire well within the confines of your fuel grate.

4.Keep your fire up on the grate and the refractory below free of excessive ashes. The fire needs plenty of air movement around the logs.

5.If smoking occurs an hour or two after lighting the fire, perhaps your well-insulated house is too airtight and there is scarcely any way for replacement air to enter and feed the fire. Check to see if your outside combustion air kit (if installed) is open. Check outside to ensure no obstructions are in front of exterior air entry. Open a window slightly, open doors to one or two rooms and see if this stops the smoking.

6.Is a vent fan, exhaust hood or central heating/cooling system stealing combustion air from your fireplace? If their volume is high enough, this can cause negative pressure and an unwanted downdraft – and smoking.

7.Is your wood fuel too wet or unseasoned? Or does it contain some chemical substance that causes sputtering, smoking and toxic fumes?

8.Figure 6 illustrates the correct height of your chimney top. It is unlikely that your instal- lation does not adhere to the installation instructions. However, if not correct, you could experience an unusual downdraft. Usually, the best solution is to increase the chimney height. This may also be necessary if nearby trees, adjoining roof lines or a hill is causing a down- draft condition.

9.Remember, your fireplace has been de- signed as a supplemental heating device only, it is not intended to heat your entire home.

Image 6
Contents Retain These Instructions For Future Reference Document in a safe place for future referenceTable of Contents General InformationFuels Wood Fuel Pointers Disposal of AshesSoftwood VS Hardwood Starting a Fire Glass Door Operating SafetyPrecautions and Instructions During Fireplace OperationCombustion AIR Combustion Air ControlRefractories Before Each Use Maintenance GuidelinesTroubleshooting Twice a Year CHECK-UPReplacement Parts Accessory ComponentsWarranty Product Reference InformationReplacement Parts ModelsDescription

BCI-36/42-2, BRI-36/42-2, BC-36/42-2, BRI-36/42, BR-36/42-2 specifications

The Superior BRI-36/42, BRI-36/42-2, BCI-36/42, BC-36/42-2, and BR-36/42-2 represent a series of advanced technological products designed for industrial applications. These models are engineered to meet the evolving needs of modern operations, offering a blend of efficiency, reliability, and cutting-edge features.

One of the main characteristics of these units is their robust construction, ensuring durability under demanding conditions. They typically feature a heavy-duty chassis that can withstand extreme temperatures and corrosive environments, making them suitable for various industries, including manufacturing, logistics, and construction.

Each of these models incorporates energy-efficient technologies, significantly reducing operating costs. The BRI-36/42 and its variants utilize high-performance motors coupled with intelligent energy management systems. This leads to lower energy consumption without compromising on performance, aligning with global sustainability goals.

The BCI-36/42 distinguishes itself with its advanced control systems. These systems allow for real-time monitoring and adjustments, optimizing productivity and minimizing downtime. The user-friendly interface ensures that operators can easily navigate through settings and operational data. The integration of IoT technologies facilitates remote monitoring, meaning operators can receive alerts and manage operations from virtually anywhere.

The BC-36/42-2 focuses on versatility. Designed to handle a wide range of payloads, this model stands out with its adjustable configurations, which allow for customization based on specific operational needs. It easily adapts to various tasks, ensuring maximum efficiency and flexibility in operations.

Notably, the BR-36/42-2 is engineered with safety as a top priority. Equipped with multiple safety features such as emergency stop buttons, safety interlocks, and advanced sensor technology, these units ensure a secure working environment for all personnel. Regular maintenance is also simplified, with built-in diagnostics that alert operators to potential issues before they escalate.

In summary, the Superior BRI-36/42 series and its variants encapsulate the latest advancements in industrial technology. With their robust construction, energy-efficient operation, advanced control systems, versatile design, and strong safety measures, these models are poised to meet the demands of modern industries while enhancing productivity and reducing operational costs. These features make the BRI-36/42 series a valuable investment for businesses seeking reliable and efficient solutions.