Operation | 4 |
OPERATION
Do not touch sump pump, pump motor, water, or discharge piping
when pump is connected to electrical power. Always disconnect pump cord (power) before handling.
1.Plug this unit into a 115V outlet, on an individ- ual branch circuit, with a Class A, 15 amp GFCI (Ground Fault Circuit Interrupter). Consult your local electrician for information and availability.
2.Fill sump pit with water, pump will start auto- matically when lower rod stop actuates switch lever arm. When upper rod stop actuates
switch lever arm, pump will stop. NOTICE: Do not allow pump to run dry.
Before attempting to service, always disconnect power
from unit.
3.The motor is equipped with an automatic reset thermal protector to protect unit from overheat- ing. When motor has cooled sufficiently, switch will reset automatically and restart motor.
Repeated tripping could be caused by low volt- age, long extension cords, clogged impeller, very low head or lift, etc. Cycling of protector will cause eventual motor burnout.
Troubleshooting
Unplug pump from power receptacle before working on pump.
SYMPTOM | POSSIBLE CAUSE(S) | CORRECTIVE ACTION |
Motor will not | No electrical power | Check fuse, circuit breaker, power cord and |
startor run |
| electrical outlet. |
| Low line voltage | If voltage wiring under recommended minimum, |
|
| check size of wiring from main source. If OK, |
|
| contact Electric Company or local Hydro authority. |
| Faulty automatic switch | Operate switch manually and replace if inoperative. |
| Float or float rod stuck | Check to see float is not rubbing sump wall or float |
|
| rod rubbing or stuck against sump cover. |
| Waterlogged float | Replace float if filled with water. |
| Motor overload tripped | If pump has been running and stops before sump |
|
| is emptied, automatic overload may have tripped. |
|
| Check inlet screen to be sure impeller is not |
|
| jammed. If so, free impeller of obstruction. |
| Electrical malfunction | Check power cord, automatic switch and motor. |
|
| Replace faulty parts as needed. |
|
|
|
Motor runs but | Inlet clogged | Check inlet and clean if needed. |
pump will not | Discharge line plugged | Clear discharge line and check valve for |
pump |
| obstruction. |
| Low line voltage | Refer to Corrective Action on low line voltage in |
|
| above section. |
| Pump airlocked | Drill a 1/8" (3.2mm) hole in discharge pipe just |
|
| above pump body but below the check valve. |
| Broken impeller or shaft | Replace impeller or shaft as needed. |
|
|
|
Pump starts and | Improper positioning of | Lower float rod stop. |
stops too often | float rod stop |
|
| Faulty automatic switch | Replace automatic switch. |
|
|
|
Pump is noisy | Improper installation | Refer to No. 5 in Installation Instructions. |
| Noisy motor | Replace pump. |
|
|
|
Pump will not | Debris around float or | Remove debris from sump. Check to see float is |
stop running | float rod stuck | not rubbing sump wall or float rod rubbing or stuck |
|
| against sump cover. |
| Faulty automatic switch | Replace switch. |
| Motor defective | Replace pump. |
|
|
|