TROUBLESHOOTING

17

TROUBLESHOOTING

Problem

Possible Causes

Solutions

 

 

 

The portable air conditioner does

Power failure / outage.

Restore the power supply.

not turn on

The automatic switch, line fuse, or breaker has

Flip the switch / change the fuse / turn the breaker back on. Also note

 

 

been tripped.

that you may have too many appliances drawing power on one circuit,

 

 

you may need to move the other appliances to another circuit.

 

The power supply voltage is too low.

Move the unit onto another circuit with the correct voltage.

 

Call for service. Only authorized personnel should replace damaged

 

The power cord is damaged.

 

power cord or power plug.

 

The L.C.D.I. power plug for the unit is tripped.

Press the Reset button on the L.C.D.I. power plug.

 

 

 

The internal water reservoir is full.

Manually drain the water by removing the drain plug.

The unit turns on but the

The room temperature is outside of the

This unit is designed to work in ambient temperatures of 61°F to 100°F.

compressor does not turn on (the

operational tolerances of the unit.

Press the MODE button until the Cooling icon is shown on the display.

fan runs but the unit is not

The Cooling mode is not on.

cooling)

Give the compressor 3 minutes to turn on after the Cooling mode has

 

 

 

The compressor has not turned on yet

been selected.

 

 

 

because of its time delay.

Set the air conditioner to a lower temperature. It is recommended to set

 

The set temperature is too high.

the temperature to at least 5°F of the ambient temperature.

 

Either manually drain the water by removing the drain plug or allow the

 

 

 

 

unit to exhaust the water itself by running the fan only mode. Then

 

The internal water reservoir is full.

cooling will resume.

 

Cancel the automatic function mode and manually set the temperature

 

 

 

 

to at least 5°F below the ambient temperature.

 

The unit is set to Automatic (Comfort) mode.

 

The air coming out of the unit is

The filter is dirty or obstructed.

Clean the air filter.

not very cold, or the airflow

 

 

volume is weak

The air intake or exhaust is obstructed.

Make sure there is at least 20" of clearance from the air intake.

 

.

Make the length of the exhaust hose is as short as possible.

 

The unit is set in dehumidifying or fan mode.

Set the unit to the cooling mode.

 

 

 