INSTALLATION COMPONENTS

 

63L10

FTF8-12

 

63L13

FTF8-18

 

H0522

FTF8-24

 

63L14

FTF8-36

Chimney Section

63L15

FTF8-48

 

 

 

Adjustable Chimney Pipe Kits

HO559

FM8-PK10

Offset/ Return Package

 

 

30 Degree Offset/Return Elbow

FTF8-ES30

63L22

15 Degree Offset/Return Elbow

FTF8-OR15

63L28

 

 

 

Firestop Spacer (30°)

63L30

F8FS30

Firestop Spacer (Flat) (Single Pack) 63L29

F8FS

Firestop Spacer (Flat) (12 Pack)

94L76

F8FS-12

 

19M55

F8F6MH

 

19M56

F8F12MH

 

63L38

(0-6/12)

F8F6

Flashing

63L39

(6/12-12/12)

F8F12

 

 

 

 

Adjustable Firestop/Thimble

HO325

FM8-AT1

Thimble Extension 26"

91L46

F8-TE26

6" Duct

Air Inlet Hood FOAK-6W

 

(optional)

Floor Inlet Assembly

FOAK-6 (standard)

Outside Air Kit (optional)

19M17

FOAK-6W

Outside Air Kit (standard)

90L83

FOAK-6

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Storm Collar

63L59

FSC

Storm Collar (12 pack)

94L77

FSC-B-12

 

 

 

 

 

 

 

 

 

 

 

 

Stabilizer

63L25

FTF8-S4

Ref. Form #750,080M

Locking Band

63L60

FLB

Contemporary Termination -

 

 

Round

63L42

FTF8-CTD

Contemporary Termination -

 

 

Round, Black

H2238

FTF8-CTDP

 

 

 

 

19

Image 19
Contents WH Report No J99025865A Wood Burning Fireplaces P/N 700,034M REV. a 03/2006Table of Contents Chimney Height IntroductionGeneral Information Clearances and Height RequirementsLocation of Fireplace Assembly OutlineChimney Enclosure Before You StartClearances Assembly StepsPRE-INSTALLATION Notes Installing the Fireplace14-1/2 FTF8 at 1 USA12/12 Back wall of Chase/Enclosure Fireplace SpecificationsProduct Reference Information Fireplace Opening WidthRoom Above Installing the Chimney SystemFTF8 Chimney FTF8 Flashing Roof PitchF8-F6 F8-F12TEN Foot Rule Summary Using a CTD TerminationLess than 10 3m 610mm Min 914mm Special Offset Instructions FTF8 Chimney Component CalculationsOffset Calculations Number Of FTF8 Height Chimney Only Number Of FTF8 HeightInches Joints StabilizerChimney Section Optional Equipment Considerations Installing OffsetsOffset Elbow Assembly Return Elbow AssemblyGas Line Connection Combustion Air KitsCold Climate Insulation Hearth Extensions and Wall Shields Glass DoorsFireplace Finishes Mantels and TrimAlternate Value per inch Listed Material T M Hearth Extension DimensionsUsing the k formula Minimum ThicknessWest Taft Avenue Orange, CA Installation ComponentsFinish to Your Taste Value = 1/k = r x thickness of material usedF8FS 700,034M REV. a 03/2006