Superior BC36MH, BCD36MH installation instructions FTF8 at 1 USA, 14-1/2, 12/12

Page 6

6

Optional

 

Floor

 

Bracket

 

1 ¹⁄₂"

Metal Safety Strips

Figure 8

 

Blocking

Metal Safety Strips

Figure 9

Step 3. Refer to fireplace drawings and speci- fications on Pages 6 and 7 for framing dimen- sions and details. Frame appliance enclosure as illustrated in Figure 12 on Page 7.

WARNING

Under no circumstances can the fireplace top spacers (see Figure

12)be removed or modified, nor may you notch the header to fit around or be installed lower than the spacers. The header may be in direct contact with the top spacers but may not be supported by them.

 

 

B

 

A

 

Ceiling Framing

 

Framing Dimensions for Ceiling

Framing Dimensions for Ceiling

Inches (millimeters)

 

Flue Type

A

B

FTF8, Vertical

14-1/2"

14-1/2"

 

(368 mm)

(368 mm)

FTF8 Offset 30°

14-1/2"

25"

 

(368 mm)

(635 mm)

Figure 10

 

 

Note: The framed depth, 20-5/8" (524 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the 20-5/8" (524 mm) must be measured from the drywall surface. It is important that this dimension be exact.

If the appliance is to be elevated above floor level, a solid continuous platform must be constructed.

The header may rest on the top metal spacers, but must not be notched to fit around them.

Consult all local codes.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

D

 

C

 

 

 

Roof Framing

 

Framing Dimensions for Roof

 

Inches

 

Pitch

FTF8 at 1" (USA)

C

D*

 

0/12

14-1/2"

14-1/2"

6/12

14-1/2"

17"

12/12

14-1/2"

21-1/2"

* Perpendicular to roof ridge

 

Figure 11

 

 

Image 6
Contents Wood Burning Fireplaces P/N 700,034M REV. a 03/2006 WH Report No J99025865ATable of Contents Clearances and Height Requirements Introduction General Information Chimney HeightBefore You Start Assembly OutlineChimney Enclosure Location of FireplaceInstalling the Fireplace Assembly StepsPRE-INSTALLATION Notes ClearancesFTF8 at 1 USA 14-1/212/12 Fireplace Opening Width Fireplace SpecificationsProduct Reference Information Back wall of Chase/EnclosureInstalling the Chimney System Room AboveF8-F12 Roof PitchF8-F6 FTF8 Chimney FTF8 FlashingUsing a CTD Termination TEN Foot Rule SummaryLess than 10 3m 610mm Min 914mm FTF8 Chimney Component Calculations Special Offset InstructionsOffset Calculations Number Of FTF8 Height Number Of FTF8 Height Chimney OnlyInches Stabilizer JointsChimney Section Return Elbow Assembly Installing OffsetsOffset Elbow Assembly Optional Equipment ConsiderationsCombustion Air Kits Gas Line ConnectionCold Climate Insulation Mantels and Trim Glass DoorsFireplace Finishes Hearth Extensions and Wall ShieldsThickness Hearth Extension DimensionsUsing the k formula Minimum Alternate Value per inch Listed Material T MValue = 1/k = r x thickness of material used Installation ComponentsFinish to Your Taste West Taft Avenue Orange, CAF8FS 700,034M REV. a 03/2006