Carrier 58MVC owner manual Open Valve

Page 6

A92185

Fig. 9 - Turn Off Electrical Supply

A05087

Fig. 10 - Remove Furnace Door

A04150

Fig. 11 - Control Switch to OFF

A04151

Fig. 12 - Control Switch to ON

A05088

Fig. 13 - Furnace Door Replaced

A92359

Fig. 14 - Turn On Electrical Supply

A06189

Fig. 15 - Open Valve

7.Replace main furnace door. (See Fig. 13.)

8.Turn ON the electrical supply to the furnace and wait 1 minute. (See Fig. 14.)

9.Open the external manual gas valve. (See Fig. 15.)

10.Set the room thermostat to a temperature slightly above the

room temperature. This will automatically signal the furnace to start.

11.When the furnace receives the start signal, the inducer is started. When the pressure switch senses that there is suf-

ficient combustion air. the hot surface igniter is energized. After the hot surface igniter is heated for 17 seconds, the gas valve permits gas to flow to the main burners. After ignition and a time delay of about 30 sec, the furnace blower will start.

Variable-capacity furnaces start at medium speed until the

control makes the necessary adjustments to operate the

blower at either the low-, medium-, or high-heat speed.

NOTE: If the burners fail to ignite after 4 attempts, the furnace control system will lock out. If lockout occurs, main burners fail to light, or blower does not come on. shut down the furnace and call your dealer for service.

12.Set your thermostat to the temperature that satisfies your comfort requirements.

Image 6
Contents Fire or Explosion Hazard Rn to the ExpertgThis Manual Must be Left with the Equipment User Carbon Monoxide Poisoning HazardContents Welcome to a NEW Generation of ComfortFurnace Components Venting Fire and Unit Operation HazardSteps For Starting Your Furnace Before Starting Your FurnaceStarting and Shutting Down Your Furnace Fire and Explosion HazardOpen Valve Performing Routine Maintenance Shutting Down Your FurnaceUnit and Property Damage Filtering Out Trouble Unit Performance HazardLocated IJ L Furnace AIR Filter FilterDoor Personal Injury HazardCombustion Area and Vent System Heading South for WINTER? Dont Forget Your FurnaceIf your furnace makes an especially loud noise when CHECK-UP Checklist Remove upper inducer housing drain connection cap. See FigUnit and Property Damage Hazard Before YOU Request a Service Call If Furnace Fails to OperateTurn to the Expertg
Related manuals
Manual 14 pages 44.72 Kb

58MVC specifications

The Carrier 58MVC is a significant advancement in residential heating and cooling solutions, harnessing the power of innovative technologies to deliver optimal comfort and energy efficiency. Designed and engineered by Carrier, a leader in HVAC systems, the 58MVC model stands out due to its advanced features and reliable performance.

One of the key characteristics of the Carrier 58MVC is its variable-speed gas furnace operation. This technology allows the unit to adjust its speed based on the heating demands of the home. As a result, homeowners experience consistent temperature control and reduced energy consumption compared to traditional single-stage systems. The variable-speed blower contributes to this efficiency by providing precise airflow, ensuring that every room in the home is evenly heated.

In terms of efficiency ratings, the Carrier 58MVC is equipped with high Annual Fuel Utilization Efficiency (AFUE) ratings, often exceeding 90%. This not only translates to lower energy bills but also indicates that the system is environmentally friendly, contributing to reduced greenhouse gas emissions. The model includes a dual fuel capability, allowing for the integration of heat pumps, enabling homeowners to alternate between gas and electric heating for maximum energy efficiency.

Another noteworthy feature of the 58MVC is its quiet operation. The unit is designed with sound-absorbing materials and a specially engineered blower that minimizes noise levels, making it ideal for any part of the home. The reduced operational noise creates a more pleasant living environment without sacrificing performance.

The Carrier 58MVC also incorporates advanced controls and smart technology, allowing users to monitor and manage their HVAC system remotely. Homeowners can take advantage of Wi-Fi connectivity to control settings from their smartphones or tablets, enhancing convenience and ensuring the system runs efficiently even when they're away.

Durability is yet another aspect of the Carrier 58MVC. Constructed with high-quality materials and designed to withstand the rigors of operation, this furnace features a stainless steel heat exchanger that resists corrosion and extends the lifespan of the unit.

In summary, the Carrier 58MVC gas furnace represents a blend of cutting-edge technology, energy efficiency, and comfort. Its variable-speed operation, high AFUE rating, quiet performance, smart controls, and robust durability make it an excellent choice for homeowners looking to invest in a reliable and efficient heating solution. Whether it's braving the winter chill or managing indoor air quality, the 58MVC stands equipped to deliver exceptional performance year-round.