Carrier 58MVC owner manual This Manual Must be Left with the Equipment User

Page 1

®

Turn to the Expertg

Owner's Manual

NOTE TO INSTALLER:

THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

USER: Please read all instructions in the manual and retain all manuals for future reference.

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in injury, death, or property damage.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS -Do not try to light any appliance.

-Do not touch any electrical switch; do not use any phone in your building.

-Leave the building immediately.

-Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury and/or death.

Carbon Monoxide is invisible, odorless, and toxic! Carrier

Heating and Cooling Systems recommends a carbon

monoxide alarm in your home, even if you do not own a

gas appliance. Locate the carbon monoxide alarm in the

living area of your home and away from gas appliances and

doorways to attached garages. Follow the alarm

manufacturer's instruction included with the alarm.

/

A05097

Do not use this furnace if any part has been under water. A

flood-damaged furnace is extremely dangerous. Attempts to

use the furnace can result in fire or explosion. A qualified

service agency should be contacted to inspect the furnace

and to replace all gas controls, control system parts, electrical parts that have been wet or the furnace if deemed necessary.

Image 1
Contents Fire or Explosion Hazard This Manual Must be Left with the Equipment UserCarbon Monoxide Poisoning Hazard Welcome to a NEW Generation of Comfort ContentsLED Furnace ComponentsFire and Unit Operation Hazard Safety rulesSteps For Starting Your Furnace Starting and Shutting Down Your FurnaceTurn Off Electrical Supply Temperature that Performing Routine MaintenanceShutting Down Your Furnace CUT Hazard Filtering Out TroubleSlide Air Filter Out of Furnace Air FilterPersonal Injury Hazard Furnace AIR FilterHeading South for WINTER? Dont Forget Your Furnace Combustion Area and Vent SystemNot Operate Your Furnace Unit Operation HazardUnit and Property Damage Hazard CHECK-UP ChecklistFor Insufficient Airflow Before YOU Request a Service CallIf Furnace Fails to Operate Turn to the Expertg
Related manuals
Manual 14 pages 55.61 Kb

58MVC specifications

The Carrier 58MVC is a significant advancement in residential heating and cooling solutions, harnessing the power of innovative technologies to deliver optimal comfort and energy efficiency. Designed and engineered by Carrier, a leader in HVAC systems, the 58MVC model stands out due to its advanced features and reliable performance.

One of the key characteristics of the Carrier 58MVC is its variable-speed gas furnace operation. This technology allows the unit to adjust its speed based on the heating demands of the home. As a result, homeowners experience consistent temperature control and reduced energy consumption compared to traditional single-stage systems. The variable-speed blower contributes to this efficiency by providing precise airflow, ensuring that every room in the home is evenly heated.

In terms of efficiency ratings, the Carrier 58MVC is equipped with high Annual Fuel Utilization Efficiency (AFUE) ratings, often exceeding 90%. This not only translates to lower energy bills but also indicates that the system is environmentally friendly, contributing to reduced greenhouse gas emissions. The model includes a dual fuel capability, allowing for the integration of heat pumps, enabling homeowners to alternate between gas and electric heating for maximum energy efficiency.

Another noteworthy feature of the 58MVC is its quiet operation. The unit is designed with sound-absorbing materials and a specially engineered blower that minimizes noise levels, making it ideal for any part of the home. The reduced operational noise creates a more pleasant living environment without sacrificing performance.

The Carrier 58MVC also incorporates advanced controls and smart technology, allowing users to monitor and manage their HVAC system remotely. Homeowners can take advantage of Wi-Fi connectivity to control settings from their smartphones or tablets, enhancing convenience and ensuring the system runs efficiently even when they're away.

Durability is yet another aspect of the Carrier 58MVC. Constructed with high-quality materials and designed to withstand the rigors of operation, this furnace features a stainless steel heat exchanger that resists corrosion and extends the lifespan of the unit.

In summary, the Carrier 58MVC gas furnace represents a blend of cutting-edge technology, energy efficiency, and comfort. Its variable-speed operation, high AFUE rating, quiet performance, smart controls, and robust durability make it an excellent choice for homeowners looking to invest in a reliable and efficient heating solution. Whether it's braving the winter chill or managing indoor air quality, the 58MVC stands equipped to deliver exceptional performance year-round.