Carrier 58MVC owner manual Furnace AIR Filter, Personal Injury Hazard

Page 10

A93205

Fig. 29 - Replace Blower Access Panel

A05100

Fig. 30 - Furnace Door Replaced

A06192

Fig. 31 - Replace Side Filter Cabinet Door

5.If washable filter, wash filter (if dirty) in sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water

through filter in the opposite direction of airflow. Allow filter to dry.

6.Reinstall clean air filter.

7.Reinstall filter retainer (for blower compartment locations only).

8.Replace blower access panel and main furnace door (Fig. 29 and 30.) or filter cabinet door. (Fig. 31 and 32.)

9.Turn on electrical supply to furnace.

If your furnace air filter needs to be replaced, be sure to use a

factory-authorized filter of the same size that was originally

supplied. Use the filter tables and compare your furnace size with the proper filter size.

 

 

 

 

 

 

 

 

 

A06193

 

Fig.

32 - Replace

Bottom Filter Cabinet Door

 

 

FURNACE

AIR

FILTER

TABLE

 

 

AIR FILTER LOCATED IN BLOWER COMPARTMENT

 

FURNACE

 

 

FILTER SIZE - IN (mm)

 

 

CASING

 

 

 

FILTER

 

 

 

 

 

 

 

WIDTH

Side

Return1-*

Bottom Return*

TYPE

IN (mm)

 

 

 

 

 

 

 

 

 

17

1/2

(1)

16X25X3/4

(1) 16X25X3/4

Washable

(445)

(406

 

X 635

X 19)

(406

X 635

X 19)

 

21 (533)

(1)

16X25X3/4

1) 20

X 25 X 3/4

Washable

 

 

(406

 

X 635

X 19)

(508

X 635

X 19)

 

24

1/2

(1or2)

16X25X

(1) 24 X 25

X 3/4

Washable

 

 

 

 

3/4

 

(622)

(406

 

X 635

X 19)

(610

X 635

X 19)

 

 

AIR FILTER LOCATED IN FILTER CABINET

FILTER

CABINET

FILTER

FILTER

HEIGHT

SIZE

TYPE

IN (mm)

IN (mm)

 

16

(406)

(1) 16 x 25 x 3/4"

Washable

 

 

(406 X 635 X 19)

(1)20 x 25 x 3/4"

(508 X 635 X 19)

20

(508)

or

Washable

 

(1) 20

x 25

x 4-5/16

 

(508 X 635 X 11o)

 

(1) 24 x 25 x 3/4"

 

(610 X 635 X 19)

24

(610)

or

Washable

 

(1) 24

x 25

 

x 4-5/16

 

(610 X 635 X 11o)

*Factory-provided with the furnace. Filters may be field modified by cutting filter material and support rods (3) in filters.

1- Upflow only. Alternate sizes and additional filters may be ordered from your dealer.

PERSONAL INJURY HAZARD

Failure to follow this warning could result in personal iniury.

Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends. Wear safety

glasses, gloves, and appropriate protective clothing.

10

Image 10
Contents Fire or Explosion Hazard This Manual Must be Left with the Equipment UserCarbon Monoxide Poisoning Hazard Contents Welcome to a NEW Generation of ComfortFurnace Components LEDSafety rules Fire and Unit Operation HazardStarting and Shutting Down Your Furnace Steps For Starting Your FurnaceTurn Off Electrical Supply Temperature that Performing Routine MaintenanceShutting Down Your Furnace Filtering Out Trouble CUT HazardAir Filter Slide Air Filter Out of FurnaceFurnace AIR Filter Personal Injury HazardNot Operate Your Furnace Combustion Area and Vent SystemHeading South for WINTER? Dont Forget Your Furnace Unit Operation HazardCHECK-UP Checklist Unit and Property Damage HazardFor Insufficient Airflow Before YOU Request a Service CallIf Furnace Fails to Operate Turn to the Expertg
Related manuals
Manual 14 pages 55.61 Kb

58MVC specifications

The Carrier 58MVC is a significant advancement in residential heating and cooling solutions, harnessing the power of innovative technologies to deliver optimal comfort and energy efficiency. Designed and engineered by Carrier, a leader in HVAC systems, the 58MVC model stands out due to its advanced features and reliable performance.

One of the key characteristics of the Carrier 58MVC is its variable-speed gas furnace operation. This technology allows the unit to adjust its speed based on the heating demands of the home. As a result, homeowners experience consistent temperature control and reduced energy consumption compared to traditional single-stage systems. The variable-speed blower contributes to this efficiency by providing precise airflow, ensuring that every room in the home is evenly heated.

In terms of efficiency ratings, the Carrier 58MVC is equipped with high Annual Fuel Utilization Efficiency (AFUE) ratings, often exceeding 90%. This not only translates to lower energy bills but also indicates that the system is environmentally friendly, contributing to reduced greenhouse gas emissions. The model includes a dual fuel capability, allowing for the integration of heat pumps, enabling homeowners to alternate between gas and electric heating for maximum energy efficiency.

Another noteworthy feature of the 58MVC is its quiet operation. The unit is designed with sound-absorbing materials and a specially engineered blower that minimizes noise levels, making it ideal for any part of the home. The reduced operational noise creates a more pleasant living environment without sacrificing performance.

The Carrier 58MVC also incorporates advanced controls and smart technology, allowing users to monitor and manage their HVAC system remotely. Homeowners can take advantage of Wi-Fi connectivity to control settings from their smartphones or tablets, enhancing convenience and ensuring the system runs efficiently even when they're away.

Durability is yet another aspect of the Carrier 58MVC. Constructed with high-quality materials and designed to withstand the rigors of operation, this furnace features a stainless steel heat exchanger that resists corrosion and extends the lifespan of the unit.

In summary, the Carrier 58MVC gas furnace represents a blend of cutting-edge technology, energy efficiency, and comfort. Its variable-speed operation, high AFUE rating, quiet performance, smart controls, and robust durability make it an excellent choice for homeowners looking to invest in a reliable and efficient heating solution. Whether it's braving the winter chill or managing indoor air quality, the 58MVC stands equipped to deliver exceptional performance year-round.