Carrier manual 1112, For 58MTB and 58MVB For 58MCB and 58MXB

Page 6

￿

CL

O

S

E

1112

3.Turn OFF electrical supply to the furnace. (See Fig. 12.)

4.Remove main furnace door. (See Fig. 13.)

13

5.The gas valve will have a control switch to turn off and on. Turn the control switch on the gas control to the OFF position and wait 5 minutes. (See Fig. 14 or 15.) Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” on furnace label. If you don’t smell

gas, go to next step.

OFF

ON

OR

For 58MTB and 58MVB

16

 

M

1

O

P

3

F

 

F

 

2

 

C

 

 

 

ON

 

For 58MCB and 58MXB

17

6.After waiting 5 minutes, turn the control switch on the gas control to the ON position. (See Fig. 16 or 17.)

OR

OFF

ON

A05100

18

OP

E

N

For 58MTB and 58MVB

14

 

M

1

O

P

3

F

C

2

F

ON

For 58MCB and 58MXB

1920

7.Replace main furnace door. (See Fig. 18.)

8.Turn ON the electrical supply to the furnace and wait 1 minute. (See Fig. 19.)

9.Open the external manual gas valve. (See Fig. 20.)

10.Set the room thermostat to a temperature slightly above the room temperature. This will automatically signal the furnace to start.

11.When the furnace receives the start signal, the inducer is

15started. When the pressure switch senses that there is suf- ficient combustion air, the hot surface igniter is energized.

6

Image 6
Contents MULTIPOISE, Condensing Direct VENT/NON-DIRECT Vent 58MCB, 58MTB, 58MVB, 58MXBModels 58MXB Shown Table of ContentsWelcome to a NEW Generation of Comfort FurnacesFurnace Components Models 58MCB, 58MXB, and 58MTB Furnaces Upflow PositionModel 58MVB Furnace Upflow Position Safety Considerations These safety rulesFire or Explosion Hazard Starting and Shutting Down Your FurnaceSteps for Starting Your Furnace Fire and Unit Operation Hazard1112 For 58MTB and 58MVB For 58MCB and 58MXBFor 58MTB and 58MVB For 58MCB and 58MXB 1920 Performing Routine Maintenance Shutting Down Your FurnaceUnit and Property Damage AIR Filter Located in Blower Compartment Bottom Filtering OUT TroubleAIR Filterss Located in Blower COMPART- Ment AIR Filters Loacted in Blower COMPART- Ment SideCombustion Area and Vent System Personal Injury Hazard3940 Heading South for the WINTER?DON’T Forget Your Furnace For Insufficient Airflow CHECK-UP ChecklistBefore YOU Request a Service Call If Furnace Fails to OperateAIR Conditioner or Heat Pump Indoor Coil