THERMOSTAT LOCATION (SG MODELS)

CAUTION — Do not run wire behind ßanges of Header Plate or in any location where it might be damaged.

Millivolt wall thermostats are specially designed for use on self- generating systems. They should never be used on line or low voltage A.C. circuits.

Interior Wall — The thermostat should be installed on an inside wall away from the furnace but in the same room.

Note: Use 16 gauge wire to prevent excessive loss of milli- volts.

Proper operation depends on a good pilot ßame. The ßame must cover the top of the thermopile. Cleaning of the pilot oriÞce and burner may be required due to spiders.

System Check (Figure 7)

A millivolt meter is required to check the system. Millivolt readings should be:

Across the thermopile terminals, 400-450 millivolts with thermostat OFF.

Across the thermopile terminals, 150-250 millivolts with thermostat ON.

Across the thermostat wires at the valve, less than 30 millivolts with thermostat ON.

Across the thermostat wires at the thermostat, less than 5 millivolts with thermostat ON. (Dirty pilot or low pressure will reduce readings.)

Connect thermostat wires to gas valve as shown in Figure 7.

Figure 7

12426-4-0104

Page 11

Image 11
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsInsulated Vent Enclosure Recommended Vent ConfigurationOval all parts purchase locally Checking Manifold Pressure Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyROUGH-IN Instructions ClearancesVentilation and Combustion AIR Location ALL ModelsPlastering Figure Installing Furnace FigureFinishing Instructions Outer Casing Figure Finishing InstructionsSystem Check Figure Thermostat Location SG ModelsTurn clockwise OFF Lighting InstructionsProper Pilot Flame Vent Safety Shutoff SystemProper Main Burner Flame If Pilot Does Not Light By Any Means TroubleshootingMain Gas Valve Does Not Open When Thermostat Is Turned On Pilot Does Not LightEmpire Comfort Systems, Inc. Nine Eighteen Freeburg Ave Parts ListHOW to Order Repair Parts Parts View Models Remote Bulb Control Installation InstructionsGWT-25 SG, RB, GWT-35 SG, RB, GWT-50 SG, RB Optional Blower Installation InstructionsGWTB-2 Wiring Diagram Service Notes

RB), GWT-50-2 specifications

Empire Comfort Systems GWT-50-2, RB is a versatile and efficient gas wall heater that showcases innovative technology and thoughtful design, making it an ideal heating solution for both residential and commercial spaces. Designed for optimal performance, the GWT-50-2, RB delivers reliable warmth even in the coldest of climates, ensuring comfort without the hassle of traditional heating methods.

One of the defining characteristics of the GWT-50-2, RB is its 50,000 BTU output, providing substantial heating capability. This unit can effectively heat spaces up to 1,000 square feet, making it suitable for larger rooms or open-plan areas. Its compact design and wall-mounted installation save valuable floor space while still offering robust heating power.

Featuring a direct vent design, the heater draws fresh air from outside for combustion and expels exhaust gases, ensuring safe and efficient operation. This design not only enhances efficiency but also protects indoor air quality by minimizing the risk of harmful fumes infiltrating living areas.

The GWT-50-2, RB comes equipped with a robust electronic ignition system, which allows for easy start-up without the need for a standing pilot light. This feature also contributes to energy savings, as the heater can operate only when needed. The advanced thermostat controls allow users to set their preferred temperature, providing tailored comfort and reducing energy consumption.

Another notable feature is the energy-efficient design of the heater, which includes a fan-blower system that circulates warm air throughout the room. This enhances thermal distribution, ensuring that heat reaches every corner of the space without any cold spots.

Additionally, the sleek and stylish appearance of the GWT-50-2, RB allows it to blend harmoniously with various interior decors. Available in multiple finishes, it can be a complementary addition to any home or office environment.

In summary, the Empire Comfort Systems GWT-50-2, RB stands out as a powerful yet efficient heating solution. Its high BTU output, energy-efficient technology, user-friendly controls, and aesthetically pleasing design make it an excellent choice for anyone seeking reliable comfort in their living or working spaces. With Empire's commitment to quality and innovation, users can trust that this gas wall heater will provide comfort and warmth for years to come.